The determination of linear and angular penetration of the femoral head into the acetabular component as an assessment of wear in total hip replacement: a comparison of four computer-assisted methods.

C H Geerdink1, B Grimm, W Vencken, I C Heyligers, A J Tonino.   

Abstract

We have compared four computer-assisted methods to measure penetration of the femoral head into the acetabular component in total hip replacement. These were the Martell Hip Analysis suite 7.14, Rogan HyperOrtho, Rogan View Pro-X and Roman v1.70. The images used for the investigation comprised 24 anteroposterior digital radiographs and 24 conventional acetate radiographs which were scanned to provide digital images. These radiographs were acquired from 24 patients with an uncemented total hip replacement with a follow-up of approximately eight years (mean 8.1; 6.3 to 9.1). Each image was measured twice by two blinded observers. The mean annual rates of penetration of the femoral head measured in the eight-year single image analysis were: Martell, 0.24 (SD 0.19); HyperOrtho, 0.12 (SD 0.08); View Pro-X, 0.12 (SD 0.06); Roman, 0.12 (SD 0.07). In paired analysis of the six-month and eight-year radiographs: Martell, 0.35 (SD 0.22); HyperOrtho, 0.15 (SD 0.13); View Pro-X, 0.11 (SD 0.06); Roman, 0.11 (SD 0.07). The intra- and inter-observer variability for the paired analysis was best for View Pro-X and Roman software, with intraclass correlations of 0.97, 0.87 and 0.96, 0.87, respectively, and worst for HyperOrtho and Martell, with intraclass correlations of 0.46, 0.13 and 0.33, 0.39, respectively. The Roman method proved the most precise and the most easy to use in clinical practice and the software is available free of charge. The Martell method showed the lowest precision, indicating a problem with its edge detection algorithm on digital images.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18591589     DOI: 10.1302/0301-620X.90B7.20305

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  20 in total

1.  Polyethylene wear is related to patient-specific contact stress in THA.

Authors:  Robert Košak; Veronika Kralj-Iglič; Aleš Iglič; Matej Daniel
Journal:  Clin Orthop Relat Res       Date:  2011-09-24       Impact factor: 4.176

2.  Is the use of thin, highly cross-linked polyethylene liners safe in total hip arthroplasty?

Authors:  Julio J Jauregui; Qais Naziri; Todd P Pierce; Randa K Elmallah; Jeffrey J Cherian; Ronald E Delanois; Michael A Mont
Journal:  Int Orthop       Date:  2015-07-02       Impact factor: 3.075

3.  Size of ischial fibro-ostosis is associated with heterotopic ossification after total hip arthroplasty.

Authors:  Jakob Bollmann; Christian Bergdolt; Peter R Aldinger; Michael W Maier; Tobias Gotterbarm; Christian Merle
Journal:  Int Orthop       Date:  2018-12-13       Impact factor: 3.075

4.  Early reactive synovitis and osteolysis after total hip arthroplasty.

Authors:  H John Cooper; Amar S Ranawat; Hollis G Potter; Li Foong Foo; Trevor W Koob; Chitranjan S Ranawat
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

5.  Analysis of polyethylene wear in plain radiographs.

Authors:  Maiken Stilling; Kjeld Søballe; Niels Trolle Andersen; Kristian Larsen; Ole Rahbek
Journal:  Acta Orthop       Date:  2009-12       Impact factor: 3.717

6.  Cross-linked compared with historical polyethylene in THA: an 8-year clinical study.

Authors:  Carel H Geerdink; Bernd Grimm; Wendy Vencken; Ide C Heyligers; Alphons J Tonino
Journal:  Clin Orthop Relat Res       Date:  2008-11-22       Impact factor: 4.176

7.  High hip center technique using a biconical threaded Zweymüller cup in osteoarthritis secondary to congenital hip disease.

Authors:  Nikolaos A Christodoulou; Konstantinos P Dialetis; Athanasios N Christodoulou
Journal:  Clin Orthop Relat Res       Date:  2010-01-05       Impact factor: 4.176

8.  Radiographic evaluation of linear wear of bipolar hemiarthroplasty devices in vivo.

Authors:  Nobuhiro Kaku; Shouhei Noda; Tomonori Tabata; Hiroaki Tagomori; Hiroshi Tsumura
Journal:  J Clin Orthop Trauma       Date:  2018-07-20

9.  The Survivorship of the Uncemented Iso-Elastic Monoblock Acetabular Component at a Mean of 6-Year Follow-up.

Authors:  T E Snijders; J J Halma; J R A Massier; S M van Gaalen; A de Gast
Journal:  HSS J       Date:  2019-04-10

10.  THR Simulator--the software for generating radiographs of THR prosthesis.

Authors:  Tai-Yin Wu; Rong-Sen Yang; Chiou-Shann Fuh; Sheng-Mou Hou; Chen-Kun Liaw
Journal:  BMC Musculoskelet Disord       Date:  2009-01-16       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.