Literature DB >> 28106229

The RM Pressfit vitamys: 5-year Swiss experience of the first 100 cups.

Michael Wyatt1, Jan Weidner1, Dominik Pfluger1, Martin Beck1.   

Abstract

BACKGROUND: The RM Pressfit vitamys is a titanium particle-coated monoblock cup with vitamin E stabilised highly cross-linked polyethylene. Initial fixation is achieved via press-fit with subsequent stability by bone on-growth. This is the first study to report the 5-year results of this design.
METHODS: We performed a prospective cohort study according to STROBE guidelines of 100 consecutive total hip replacements (THRs) in 92 patients all with ceramic heads. Demographic data, pre/postoperative visual analogue scale (VAS) for pain and satisfaction, Harris Hip Scores (HHS) and complications were recorded. Radiographic analysis of osteolysis and loosening was complemented by EBRA (Einzel-Bild-Röntgen-Analyse) evaluation of cup movement.
RESULTS: Our cohort comprised 48 women (mean age 67; SD 10.4) and 44 men (mean age 69; SD 7.8). The mean body mass index was 27 kg/m2 (SD 4.6). Surgical indications were osteoarthritis 96%, avascular necrosis 3% and fracture 1%. 82% had a direct anterior approach, 15% anterolateral and 3% trans-gluteal. 4 surgeons were involved. 1 cup was repositioned and fixed with screws within a week of index surgery. There were 2 intraoperative femoral fractures, 3 haematomata with 1 requiring drainage and 1 deep infection settling with an open washout and modular exchange. Mean VAS satisfaction increased from 3.8 (SD 2.0) to 8.8 at 6 weeks (SD 1.4) and 9.5 (SD 1.3) at 5 years. The HHS functional scores were 58.9 (SD 13.2) preoperatively and 94.6 (SD 6.6) at 5 years. Radiographic analysis showed neither progressive radiolucency nor osteolysis. Mean migration was 1.5 mm after 5 years.
CONCLUSIONS: Mid-term results of the RM Pressfit vitamys cup are encouraging.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28106229     DOI: 10.5301/hipint.5000469

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  4 in total

1.  The Survivorship of the Uncemented Iso-Elastic Monoblock Acetabular Component at a Mean of 6-Year Follow-up.

Authors:  T E Snijders; J J Halma; J R A Massier; S M van Gaalen; A de Gast
Journal:  HSS J       Date:  2019-04-10

2.  Preliminary report of clinical experience with metal-on-highly-crosslinked-polyethylene hip resurfacing.

Authors:  Ronan B C Treacy; James P Holland; Joseph Daniel; Hena Ziaee; Derek J W McMinn
Journal:  Bone Joint Res       Date:  2019-11-02       Impact factor: 5.853

3.  To cement or not to cement acetabular cups in total hip arthroplasty: a systematic review and re-evaluation.

Authors:  Frank Van Praet; Michiel Mulier
Journal:  SICOT J       Date:  2019-10-01

4.  The concept of a cementless isoelastic monoblock cup made of highly cross-linked polyethylene infused with vitamin E: radiological analyses of migration and wear using EBRA and clinical outcomes at mid-term follow-up.

Authors:  Yama Afghanyar; Sebastian Joser; Jonas Tecle; Philipp Drees; Jens Dargel; Philipp Rehbein; Karl Philipp Kutzner
Journal:  BMC Musculoskelet Disord       Date:  2021-01-23       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.