The results of the titanium-coated RM acetabular component at 20 years: a long-term follow-up of an uncemented primary total hip replacement.

M Ihle1, S Mai, D Pfluger, W Siebert.   

Abstract

In a prospective study, 93 unselected consecutive uncemented hip arthroplasties were performed in 80 patients using the titanium-coated RM acetabular component and the CLS femoral component. The mean age of the patients at operation was 52 years (28 to 81). None were lost to follow-up. In the 23 patients who had died (26 hips) only one acetabular component had been revised. In the 57 living patients (67 hips), 13 such revisions had been performed. Of the 14 revisions, seven were for osteolysis, five for loosening and two for infection. Survival analysis of this implant showed a total probability of survival of 83% (95% confidence interval 73 to 90), with all revisions as the endpoint, and a probability of 94% (95% confidence interval 87 to 98) with revision for aseptic loosening as the endpoint, indicating reliable long-term fixation of the titanium-coated RM acetabular component.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18827236     DOI: 10.1302/0301-620X.90B10.20274

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  17 in total

1.  Survival of the cementless Spotorno stem in the second decade.

Authors:  Peter R Aldinger; Alexander W Jung; Steffen J Breusch; Volker Ewerbeck; Dominik Parsch
Journal:  Clin Orthop Relat Res       Date:  2009-06-06       Impact factor: 4.176

Review 2.  Do monoblock cups improve survivorship, decrease wear, or reduce osteolysis in uncemented total hip arthroplasty?

Authors:  Jelle J Halma; H Charles Vogely; Wouter J Dhert; Steven M Van Gaalen; Arthur de Gast
Journal:  Clin Orthop Relat Res       Date:  2013-08-03       Impact factor: 4.176

Review 3.  Is there evidence for a superior method of socket fixation in hip arthroplasty? A systematic review.

Authors:  Dean Pakvis; Gijs van Hellemondt; Enrico de Visser; Wilco Jacobs; Maarten Spruit
Journal:  Int Orthop       Date:  2011-03-15       Impact factor: 3.075

Review 4.  Survival outcomes of cemented compared to uncemented stems in primary total hip replacement.

Authors:  Michael Wyatt; Gary Hooper; Christopher Frampton; Alastair Rothwell
Journal:  World J Orthop       Date:  2014-11-18

5.  Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial.

Authors:  Caroline Scemama; Philippe Anract; Valérie Dumaine; Antoine Babinet; Jean Pierre Courpied; Moussa Hamadouche
Journal:  Int Orthop       Date:  2016-11-04       Impact factor: 3.075

6.  Does a titanium-coated polyethylene press-fit cup give reliable midterm results?

Authors:  Nikki Hooper; Harry Sargeant; Chris Frampton; Gary Hooper
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

7.  High failure rate of a new pressfit cup in mid-term follow-up.

Authors:  Steffen Brodt; Georg Matziolis; Christoph Windisch; Andreas Gosse; Matthias Spalteholz; Ralf Herbert Gahr
Journal:  Int Orthop       Date:  2015-07-08       Impact factor: 3.075

Review 8.  [Long-term results of uncemented stems in total hip arthroplasty: analysis of survival rates with a minimum 15-year follow-up].

Authors:  C Merle; M Clarius; P R Aldinger
Journal:  Orthopade       Date:  2010-01       Impact factor: 1.087

9.  Mid-term results of an uncemented tapered femoral stem and various factors affecting survivorship.

Authors:  Mayank Vijayvargiya; Vivek Shetty; Kiran Makwana; Harpreet Singh Suri
Journal:  J Clin Orthop Trauma       Date:  2018-02-05

10.  The Survivorship of the Uncemented Iso-Elastic Monoblock Acetabular Component at a Mean of 6-Year Follow-up.

Authors:  T E Snijders; J J Halma; J R A Massier; S M van Gaalen; A de Gast
Journal:  HSS J       Date:  2019-04-10
View more