Literature DB >> 31912310

Update on the assessment of fluid responsiveness.

Koichi Suehiro1.   

Abstract

Keywords:  Cardiac output; Fluid responsiveness; Pulse pressure variation; Stroke volume; Stroke volume variation

Year:  2020        PMID: 31912310     DOI: 10.1007/s00540-019-02731-4

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


× No keyword cloud information.
  27 in total

1.  The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients.

Authors:  Maxime Cannesson; Henri Musard; Olivier Desebbe; Cécile Boucau; Rémi Simon; Roland Hénaine; Jean-Jacques Lehot
Journal:  Anesth Analg       Date:  2009-02       Impact factor: 5.108

2.  Changes in Stroke Volume Induced by Lung Recruitment Maneuver Predict Fluid Responsiveness in Mechanically Ventilated Patients in the Operating Room.

Authors:  Matthieu Biais; Romain Lanchon; Musa Sesay; Lisa Le Gall; Bruno Pereira; Emmanuel Futier; Karine Nouette-Gaulain
Journal:  Anesthesiology       Date:  2017-02       Impact factor: 7.892

3.  Impact of non-invasive continuous blood pressure monitoring on maternal hypotension during cesarean delivery: a randomized-controlled study.

Authors:  Takashi Juri; Koichi Suehiro; Aya Kimura; Akira Mukai; Katsuaki Tanaka; Tokuhiro Yamada; Takashi Mori; Kiyonobu Nishikawa
Journal:  J Anesth       Date:  2018-09-28       Impact factor: 2.078

4.  Accuracy and trending ability of the fourth-generation FloTrac/Vigileo System™ in patients undergoing abdominal aortic aneurysm surgery.

Authors:  Takuma Maeda; Kohshi Hattori; Miho Sumiyoshi; Hiroko Kanazawa; Yoshihiko Ohnishi
Journal:  J Anesth       Date:  2018-04-03       Impact factor: 2.078

5.  Utilization of arterial pulse waveform analysis during non-cardiac surgery in Japan: a retrospective observational study using a nationwide claims database.

Authors:  Chikashi Takeda; Masato Takeuchi; Toshiyuki Mizota; Hiroshi Yonekura; Isao Nahara; Aki Kuwauchi; Woo Jin Joo; Yohei Kawasaki; Koji Kawakami
Journal:  J Anesth       Date:  2019-01-07       Impact factor: 2.078

6.  End-Expiratory Occlusion Test Predicts Fluid Responsiveness in Patients With Protective Ventilation in the Operating Room.

Authors:  Matthieu Biais; Mathilde Larghi; Jeremy Henriot; Hugues de Courson; Musa Sesay; Karine Nouette-Gaulain
Journal:  Anesth Analg       Date:  2017-12       Impact factor: 5.108

7.  The influence of the airway driving pressure on pulsed pressure variation as a predictor of fluid responsiveness.

Authors:  Laurent Muller; Guillaume Louart; Philippe-Jean Bousquet; Damien Candela; Lana Zoric; Jean-Emmanuel de La Coussaye; Samir Jaber; Jean-Yves Lefrant
Journal:  Intensive Care Med       Date:  2009-10-22       Impact factor: 17.440

8.  Central hemodynamics during lung recruitment maneuvers at hypovolemia, normovolemia and hypervolemia. A study by echocardiography and continuous pulmonary artery flow measurements in lung-injured pigs.

Authors:  Jonas Nielsen; Manja Nilsson; Filip Fredén; Jan Hultman; Ulrica Alström; Jesper Kjaergaard; Göran Hedenstierna; Anders Larsson
Journal:  Intensive Care Med       Date:  2006-03-07       Impact factor: 17.440

Review 9.  Prediction of fluid responsiveness: an update.

Authors:  Xavier Monnet; Paul E Marik; Jean-Louis Teboul
Journal:  Ann Intensive Care       Date:  2016-11-17       Impact factor: 6.925

Review 10.  What is the impact of the fluid challenge technique on diagnosis of fluid responsiveness? A systematic review and meta-analysis.

Authors:  Laura Toscani; Hollmann D Aya; Dimitra Antonakaki; Davide Bastoni; Ximena Watson; Nish Arulkumaran; Andrew Rhodes; Maurizio Cecconi
Journal:  Crit Care       Date:  2017-08-04       Impact factor: 9.097

View more
  1 in total

1.  Changes in stroke volume induced by lung recruitment maneuver can predict fluid responsiveness during intraoperative lung-protective ventilation in prone position.

Authors:  Ryota Watanabe; Koichi Suehiro; Akira Mukai; Katsuaki Tanaka; Tokuhiro Yamada; Takashi Mori; Kiyonobu Nishikawa
Journal:  BMC Anesthesiol       Date:  2021-12-02       Impact factor: 2.217

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.