Literature DB >> 31896741

Evaluation of the Precision of Different Intraoral Scanner-Computer Aided Design (CAD) Software Combinations in Digital Dentistry.

Çise Erozan1, Oğuz Ozan1.   

Abstract

BACKGROUND The aim of this study was to evaluate the precision of correlation between intraoral scanners and computer aided design (CAD) software programs used during scanning and designing phases of digital dentistry. In the present study, CAD software programs that accept data in Standard Tessellation Language (STL) and proprietary format have been evaluated and data loss has been examined in the scanned data. MATERIAL AND METHODS A single unit crown preparation was conducted for maxillary right first molar on a fully dentulous model. The prepared tooth was scanned with a high precision industrial scanner (ATOS Core 80) and the reference digital model was obtained. The dental model was further scanned 10 times using 3 different intraoral scanners (CEREC Omnicam AC, TRIOS 3 Color Pod, and Aadva IOS 100). The data obtained from the reference scanner and intraoral scanners were transferred to different CAD programs (CEREC inLab, TRIOS Design Studio, Exocad) and digital crowns were designed for each scanned data-CAD combination. After that, the data losses that occurred between these transfers were evaluated by superimposition technique in a special software (VR Mesh v7.5) (alpha=0.05). RESULTS Among the all combinations of scanner and software, Omnicam AC-InLab was determined to be the most precise combination through the full digital workflow since the Omnicam AC-Exocad combination showed the highest deviations. CONCLUSIONS Within the limitations of this in vitro study, it was determined that the combinations of scanners and associated CAD programs yielded more accurate results, and data loss was revealed when the scanned data converted from the proprietary format to the STL format.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 31896741      PMCID: PMC6977629          DOI: 10.12659/MSM.918529

Source DB:  PubMed          Journal:  Med Sci Monit        ISSN: 1234-1010


  24 in total

1.  Full arch precision of six intraoral scanners in vitro.

Authors:  C A Osnes; J H Wu; P Venezia; M Ferrari; A J Keeling
Journal:  J Prosthodont Res       Date:  2019-06-18       Impact factor: 4.642

2.  Full arch digital scanning systems performances for implant-supported fixed dental prostheses: a comparative study of 8 intraoral scanners.

Authors:  Adolfo Di Fiore; Roberto Meneghello; Lorenzo Graiff; Gianpaolo Savio; Paolo Vigolo; Carlo Monaco; Edoardo Stellini
Journal:  J Prosthodont Res       Date:  2019-05-07       Impact factor: 4.642

3.  Comparison of digital intraoral scanner reproducibility and image trueness considering repetitive experience.

Authors:  Jung-Hwa Lim; Ji-Man Park; Minji Kim; Seong-Joo Heo; Ji-Yun Myung
Journal:  J Prosthet Dent       Date:  2017-07-08       Impact factor: 3.426

4.  Effect of Software Version on the Accuracy of an Intraoral Scanning Device.

Authors:  Yasser Haddadi; Golnosh Bahrami; Flemming Isidor
Journal:  Int J Prosthodont       Date:  2018-04-06       Impact factor: 1.681

5.  Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: A novel in vivo analysis method.

Authors:  R Nedelcu; P Olsson; I Nyström; J Rydén; A Thor
Journal:  J Dent       Date:  2017-12-12       Impact factor: 4.379

6.  Effects of different types of intraoral scanners and scanning ranges on the precision of digital implant impressions in edentulous maxilla: An in vitro study.

Authors:  Keita Miyoshi; Shinpei Tanaka; Sawako Yokoyama; Minoru Sanda; Kazuyoshi Baba
Journal:  Clin Oral Implants Res       Date:  2019-10-28       Impact factor: 5.977

7.  A new method for assessing the accuracy of full arch impressions in patients.

Authors:  F Kuhr; A Schmidt; P Rehmann; B Wöstmann
Journal:  J Dent       Date:  2016-10-04       Impact factor: 4.379

8.  Intraoral Digital Impression Technique Compared to Conventional Impression Technique. A Randomized Clinical Trial.

Authors:  Björn Gjelvold; Bruno Ramos Chrcanovic; Eva-Karin Korduner; Ingrid Collin-Bagewitz; Jenö Kisch
Journal:  J Prosthodont       Date:  2015-11-30       Impact factor: 2.752

9.  Relationship between resolution and accuracy of four intraoral scanners in complete-arch impressions.

Authors:  Priscilla Medina-Sotomayor; Agustín Pascual-Moscardó; Isabel Camps
Journal:  J Clin Exp Dent       Date:  2018-04-01

10.  Influence of Intra-Oral Scanner (I.O.S.) on The Marginal Accuracy of CAD/CAM Single Crowns.

Authors:  Francesco Ferrini; Gianpaolo Sannino; Carlo Chiola; Paolo Capparé; Giorgio Gastaldi; Enrico Felice Gherlone
Journal:  Int J Environ Res Public Health       Date:  2019-02-14       Impact factor: 3.390

View more
  5 in total

1.  In Vivo Evaluation of Periodontal Phenotypes Using Cone-Beam Computed Tomography, Intraoral Scanning by Computer-Aided Design, and Prosthetic-Driven Implant Planning Technology.

Authors:  Magdalena Bednarz-Tumidajewicz; Aleksandra Sender-Janeczek; Jacek Zborowski; Tomasz Gedrange; Tomasz Konopka; Agata Prylińska-Czyżewska; Elżbieta Dembowska; Wojciech Bednarz
Journal:  Med Sci Monit       Date:  2020-10-16

2.  In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies.

Authors:  Çise Özal; Mutahhar Ulusoy
Journal:  J Adv Prosthodont       Date:  2021-12-22       Impact factor: 1.904

3.  Impact of Ceramic Material and Preparation Design on Marginal Fit of Endocrown Restorations.

Authors:  Mai Soliman; Ghadeer Alzahrani; Foton Alabdualataif; Elzahraa Eldwakhly; Sahar Alsamady; Alhanoof Aldegheishem; Manal M Abdelhafeez
Journal:  Materials (Basel)       Date:  2022-08-15       Impact factor: 3.748

4.  Comparison of the Effectiveness of the Ultrasonic Method and Cone-Beam Computed Tomography Combined with Intraoral Scanning and Prosthetic-Driven Implant Planning Method in Determining the Gingival Phenotype in the Healthy Periodontium.

Authors:  Magdalena Bednarz-Tumidajewicz; Aneta Furtak; Aneta Zakrzewska; Małgorzata Rąpała; Karolina Gerreth; Tomasz Gedrange; Wojciech Bednarz
Journal:  Int J Environ Res Public Health       Date:  2022-09-27       Impact factor: 4.614

5.  Assessment of Color Stainability of Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) Ceramic Materials After Hot and Cold Coffee Immersion at Different Time Intervals.

Authors:  Hafiz A Adawi; Mohammed M Al Mialeem; Nasser M Al Ahmari; Mansoor Shariff; Mohammed A Qahhar; Sultan M H Muharraq; Nabiel A Alghazali
Journal:  Med Sci Monit       Date:  2021-10-03
  5 in total