A new method for assessing the accuracy of full arch impressions in patients.

F Kuhr1, A Schmidt2, P Rehmann3, B Wöstmann4.   

Abstract

OBJECTIVE: To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital full arch impressions in comparison to a conventional impression procedure in clinical use.
METHODS: Four metal spheres were fixed with composite using a metal application aid to the lower teeth of 50 test subjects as reference structures. One conventional impression (Impregum Penta Soft) with subsequent type-IV gypsum model casting (CI) and three different digital impressions were performed in the lower jaw of each test person with the following intraoral scanners: Sirona CEREC Omnicam (OC), 3M True Definition (TD), Heraeus Cara TRIOS (cT). The digital and conventional (gypsum) models were analyzed relative to the spheres. Linear distance and angle measurements between the spheres, as well as digital superimpositions of the spheres with the reference data set were executed.
RESULTS: With regard to the distance measurements, CI showed the smallest deviations followed by intraoral scanners TD, cT and OC. A digital superimposition procedure yielded the same order for the outcomes: CI (15±4μm), TD (23±9μm), cT (37±14μm), OC (214±38μm). Angle measurements revealed the smallest deviation for TD (0.06°±0,07°) followed by CI (0.07°±0.07°), cT (0.13°±0.15°) and OC (0.28°±0.21°).
CONCLUSION: The new measuring method is suitable for measuring the dimensional accuracy of full arch impressions intraorally. CI is still significantly more accurate than full arch scans with intraoral scanners in clinical use. CLINICAL SIGNIFICANCE: Conventional full arch impressions with polyether impression materials are still more accurate than full arch digital impressions. Digital impression systems using powder application and active wavefront sampling technology achieve the most accurate results in comparison to other intraoral scanning systems (DRKS-ID: DRKS00009360, German Clinical Trials Register). Copyright Â
© 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  CAD/CAM; Digital impression; Full arch scan; Intraoral scanner; Polyether impression; Trueness

Mesh:

Substances:

Year:  2016        PMID: 27717754     DOI: 10.1016/j.jdent.2016.10.002

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  21 in total

1.  Accuracy of full-arch digital impressions: an in vitro and in vivo comparison.

Authors:  Christine Keul; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2019-05-27       Impact factor: 3.573

2.  A new 3D-method to assess the inter implant dimensions in patients - A pilot study.

Authors:  Alexander Schmidt; Jan-Wilhelm Billig; Maximiliane A Schlenz; Bernd Wöstmann
Journal:  J Clin Exp Dent       Date:  2020-02-01

Review 3.  Digital versus conventional full-arch impressions in linear and 3D accuracy: a systematic review and meta-analysis of in vivo studies.

Authors:  Lin Kong; Yabing Li; Zhijian Liu
Journal:  Clin Oral Investig       Date:  2022-07-04       Impact factor: 3.606

4.  The transfer accuracy of digital and conventional full-arch impressions influenced by fixed orthodontic appliances: a reference aid-based in vitro study.

Authors:  Maximiliane Amelie Schlenz; Katharina Klaus; Alexander Schmidt; Bernd Wöstmann; Marco Mersmann; Sabine Ruf; Niko Christian Bock
Journal:  Clin Oral Investig       Date:  2022-09-15       Impact factor: 3.606

5.  Influence of Applied Liquid-Type Scanning-Aid Material on the Accuracy of the Scanned Image: An In Vitro Experiment.

Authors:  Hyun-Su Oh; Young-Jun Lim; Bongju Kim; Won Hyeon Kim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  Materials (Basel)       Date:  2020-04-27       Impact factor: 3.623

6.  Finish line distinctness and accuracy in 7 intraoral scanners versus conventional impression: an in vitro descriptive comparison.

Authors:  Robert Nedelcu; Pontus Olsson; Ingela Nyström; Andreas Thor
Journal:  BMC Oral Health       Date:  2018-02-23       Impact factor: 2.757

7.  Trueness and Precision of Three-Dimensional Digitizing Intraoral Devices.

Authors:  Hussam Mutwalli; Michael Braian; Deyar Mahmood; Christel Larsson
Journal:  Int J Dent       Date:  2018-11-26

Review 8.  Accuracy of an intraoral digital impression: A review.

Authors:  Kanchan Aswani; Sattyam Wankhade; Arun Khalikar; Suryakant Deogade
Journal:  J Indian Prosthodont Soc       Date:  2020-01-27

9.  Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study.

Authors:  Álvaro Zubizarreta-Macho; Martina Triduo; Jorge Alonso Pérez-Barquero; Clara Guinot Barona; Alberto Albaladejo Martínez
Journal:  J Clin Med       Date:  2020-04-12       Impact factor: 4.241

10.  Accuracy of Digital and Conventional Full-Arch Impressions in Patients: An Update.

Authors:  Alexander Schmidt; Leona Klussmann; Bernd Wöstmann; Maximiliane Amelie Schlenz
Journal:  J Clin Med       Date:  2020-03-04       Impact factor: 4.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.