Effects of different types of intraoral scanners and scanning ranges on the precision of digital implant impressions in edentulous maxilla: An in vitro study.

Keita Miyoshi1, Shinpei Tanaka1, Sawako Yokoyama1, Minoru Sanda1, Kazuyoshi Baba1.   

Abstract

OBJECTIVE: This study aimed to evaluate the precision of digital implant impressions in comparison with conventional impressions and assess the impact of the scanning range on precision.
MATERIALS AND METHODS: An edentulous maxilla model with six implants was scanned with four intraoral scanners (IOSs) and a dental laboratory scanner five times each, and stereolithography (STL) data were generated. A conventional silicone impression was made, and a model was fabricated, which was scanned using the laboratory scanner. This procedure was also repeated five times. Nine different ranges of interest (ROIs) were defined, and the average discrepancies of the measurement points between each pair of STL images out of five for each ROI were calculated. The effects of "impression method" and "ROI" on precision, as evaluated by the averaged discrepancy, were tested by two-way analysis of variance (p < .05).
RESULTS: The effects of "impression methods" and "ROI" and their interactions were statistically significant. The discrepancies in the scanned datasets of the dental laboratory scanner were significantly lower than those in the other impression methods. The discrepancies of the IOSs were comparable with those of the laboratory scanner when the ROI was limited, however; the discrepancies deteriorated when the ROI expanded across the arch, while those of the laboratory scanner remained stable irrespective of the ROI.
CONCLUSIONS: Within the limitation of this in vitro study, digital implant impressions by IOSs may show clinically acceptable precision when the scan range is limited, such as in 3-unit superstructure supported by two implants.
© 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  dental implant; digital impression; intraoral scanner; precision; scanning range

Mesh:

Year:  2019        PMID: 31608509     DOI: 10.1111/clr.13548

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  8 in total

1.  In Vitro Comparison of Three Intraoral Scanners for Implant-Supported Dental Prostheses.

Authors:  Vitória Costa; António Sérgio Silva; Rosana Costa; Pedro Barreiros; Joana Mendes; José Manuel Mendes
Journal:  Dent J (Basel)       Date:  2022-06-15

Review 2.  The direct digital workflow in fixed implant prosthodontics: a narrative review.

Authors:  George Michelinakis; Dimitrios Apostolakis; Phophi Kamposiora; George Papavasiliou; Mutlu Özcan
Journal:  BMC Oral Health       Date:  2021-01-21       Impact factor: 2.757

Review 3.  Accuracy of Digital Dental Implants Impression Taking with Intraoral Scanners Compared with Conventional Impression Techniques: A Systematic Review of In Vitro Studies.

Authors:  María Isabel Albanchez-González; Jorge Cortés-Bretón Brinkmann; Jesús Peláez-Rico; Carlos López-Suárez; Verónica Rodríguez-Alonso; María Jesús Suárez-García
Journal:  Int J Environ Res Public Health       Date:  2022-02-11       Impact factor: 3.390

4.  Application of a new scan body for face-driven fixed prosthetics.

Authors:  Naruto Otawa; Tsukasa Aoki; Tomoki Sumida; Tsukasa Yanagi; Hirofumi Kido
Journal:  Clin Exp Dent Res       Date:  2021-08-25

5.  In Vitro Accuracy of Digital and Conventional Impressions for Full-Arch Implant-Supported Prostheses.

Authors:  Rani D'haese; Tom Vrombaut; Herman Roeykens; Stefan Vandeweghe
Journal:  J Clin Med       Date:  2022-01-25       Impact factor: 4.241

6.  Effect of assistive devices on the precision of digital impressions for implants placed in edentulous maxilla: an in vitro study.

Authors:  Rena Masu; Shinpei Tanaka; Minoru Sanda; Keita Miyoshi; Kazuyoshi Baba
Journal:  Int J Implant Dent       Date:  2021-12-13

Review 7.  Trueness and precision of digital implant impressions by intraoral scanners: a literature review.

Authors:  Minoru Sanda; Keita Miyoshi; Kazuyoshi Baba
Journal:  Int J Implant Dent       Date:  2021-07-27

8.  Evaluation of the Precision of Different Intraoral Scanner-Computer Aided Design (CAD) Software Combinations in Digital Dentistry.

Authors:  Çise Erozan; Oğuz Ozan
Journal:  Med Sci Monit       Date:  2020-01-03
  8 in total