Literature DB >> 19918903

RF shimming for spectroscopic localization in the human brain at 7 T.

Hoby P Hetherington1, Nikolai I Avdievich, Andrey M Kuznetsov, Jullie W Pan.   

Abstract

Spectroscopic imaging of the human head at short echo times (<or=15 ms) typically requires suppression of signals from extracerebral tissues. However, at 7 T, decreasing efficiency in B1+ generation (hertz/watt) and increasing spectral bandwidth result in dramatic increases in power deposition and increased chemical shift registration artifacts for conventional gradient-based in-plane localization. In this work, we describe a novel method using radiofrequency shimming and an eight-element transceiver array to generate a B1+ field distribution that excites a ring about the periphery of the head and leaves central brain regions largely unaffected. We have used this novel B1+ distribution to provide in-plane outer volume suppression (>98% suppression of extracerebral lipids) without the use of gradients. This novel B1+ distribution is used in conjunction with a double inversion recovery method to provide suppression of extracerebral resonances with T1s greater than 400 ms, while having negligible effect on metabolite ratios of cerebral resonances with T1s>1000 ms. Despite the use of two adiabatic pulses, the high efficiency of the ring distribution allows radiofrequency power deposition to be limited to 3-4 W for a pulse repetition time of 1.5 sec. The short echo time enabled the acquisition of images of the human brain, displaying glutamate, glutamine, macromolecules, and other major cerebral metabolites. Copyright (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19918903      PMCID: PMC2811270          DOI: 10.1002/mrm.22182

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  30 in total

1.  In vivo 1H2O T2+ measurement in the human occipital lobe at 4T and 7T by Carr-Purcell MRI: detection of microscopic susceptibility contrast.

Authors:  Robert Bartha; Shalom Michaeli; Hellmut Merkle; Gregor Adriany; Peter Andersen; Wei Chen; Kamil Ugurbil; Michael Garwood
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

2.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

3.  Basic considerations on the impact of the coil array on the performance of Transmit SENSE.

Authors:  U Katscher; J Röhrs; P Börnert
Journal:  MAGMA       Date:  2005-02-11       Impact factor: 2.310

4.  Potential advantage of higher-order modes of birdcage coil for parallel imaging.

Authors:  Chunsheng Wang; Peng Qu; Gary X Shen
Journal:  J Magn Reson       Date:  2006-07-10       Impact factor: 2.229

5.  Quantitation of metabolites by 1H NMR.

Authors:  J W Pan; H P Hetherington; J R Hamm; R G Shulman
Journal:  Magn Reson Med       Date:  1991-07       Impact factor: 4.668

6.  Localized proton NMR spectroscopy of brain tumors using short-echo time STEAM sequences.

Authors:  J Frahm; H Bruhn; W Hänicke; K D Merboldt; K Mursch; E Markakis
Journal:  J Comput Assist Tomogr       Date:  1991 Nov-Dec       Impact factor: 1.826

7.  Human magnetic resonance imaging at 8 T.

Authors:  P M Robitaille; A M Abduljalil; A Kangarlu; X Zhang; Y Yu; R Burgess; S Bair; P Noa; L Yang; H Zhu; B Palmer; Z Jiang; D M Chakeres; D Spigos
Journal:  NMR Biomed       Date:  1998-10       Impact factor: 4.044

8.  Interleaved narrow-band PRESS sequence with adiabatic spatial-spectral refocusing pulses for 1H MRSI at 7T.

Authors:  Priti Balchandani; John Pauly; Daniel Spielman
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

9.  Fat suppression for 1H MRSI at 7T using spectrally selective adiabatic inversion recovery.

Authors:  Priti Balchandani; Daniel Spielman
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

10.  High-flip-angle slice-selective parallel RF transmission with 8 channels at 7 T.

Authors:  Kawin Setsompop; Vijayanand Alagappan; Adam C Zelinski; Andreas Potthast; Ulrich Fontius; Franz Hebrank; Franz Schmitt; Lawrence L Wald; Elfar Adalsteinsson
Journal:  J Magn Reson       Date:  2008-08-30       Impact factor: 2.229

View more
  43 in total

1.  Multislice ¹H MRSI of the human brain at 7 T using dynamic B₀ and B₁ shimming.

Authors:  Vincent O Boer; Dennis W J Klomp; Christoph Juchem; Peter R Luijten; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

2.  J-refocused coherence transfer spectroscopic imaging at 7 T in human brain.

Authors:  J W Pan; N Avdievich; H P Hetherington
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

3.  Dynamically applied B1+ shimming solutions for non-contrast enhanced renal angiography at 7.0 Tesla.

Authors:  Gregory J Metzger; Edward J Auerbach; Can Akgun; Josh Simonson; Xiaoming Bi; Kâmil Uğurbil; Pierre-François van de Moortele
Journal:  Magn Reson Med       Date:  2012-03-22       Impact factor: 4.668

4.  Role of very high order and degree B0 shimming for spectroscopic imaging of the human brain at 7 tesla.

Authors:  Jullie W Pan; Kai-Ming Lo; Hoby P Hetherington
Journal:  Magn Reson Med       Date:  2011-12-28       Impact factor: 4.668

Review 5.  Utility of magnetic resonance spectroscopic imaging for human epilepsy.

Authors:  Jullie W Pan; Ruben I Kuzniecky
Journal:  Quant Imaging Med Surg       Date:  2015-04

6.  Robust outer volume suppression utilizing elliptical pulsed second order fields (ECLIPSE) for human brain proton MRSI.

Authors:  Chathura Kumaragamage; Henk M De Feyter; Peter Brown; Scott McIntyre; Terence W Nixon; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2019-11-19       Impact factor: 4.668

7.  Regional neurochemical profiles in the human brain measured by ¹H MRS at 7 T using local B₁ shimming.

Authors:  Uzay E Emir; Edward J Auerbach; Pierre-Francois Van De Moortele; Małgorzata Marjańska; Kamil Uğurbil; Melissa Terpstra; Ivan Tkáč; Gülin Oz
Journal:  NMR Biomed       Date:  2011-07-15       Impact factor: 4.044

8.  Selective homonuclear polarization transfer for spectroscopic imaging of GABA at 7T.

Authors:  J W Pan; R B Duckrow; D D Spencer; N I Avdievich; H P Hetherington
Journal:  Magn Reson Med       Date:  2012-04-13       Impact factor: 4.668

9.  Fast 3D rosette spectroscopic imaging of neocortical abnormalities at 3 T: Assessment of spectral quality.

Authors:  Claudiu V Schirda; Tiejun Zhao; Victor E Yushmanov; Yoojin Lee; Gena R Ghearing; Frank S Lieberman; Ashok Panigrahy; Hoby P Hetherington; Jullie W Pan
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

10.  In vivo detection of 2-hydroxyglutarate in brain tumors by optimized point-resolved spectroscopy (PRESS) at 7T.

Authors:  Sandeep K Ganji; Zhongxu An; Vivek Tiwari; Sarah McNeil; Marco C Pinho; Edward Pan; Bruce E Mickey; Elizabeth A Maher; Changho Choi
Journal:  Magn Reson Med       Date:  2016-03-16       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.