Performance Evaluation of Automated Immunohematology Analyzer IH-500 for Blood Bank Testing.

Sang Hyuk Park1, Jaewook Kim1, Ji-Hun Lim1, Joseph Jeong1, Seon-Ho Lee1.   

Abstract

The automated immunohematology analyzer IH-500 (Bio-rad, Cressier FR, Switzerland) was developed recently for blood bank tests and this study evaluated performance of IH-500. 200 blood samples for ABO/Rh typing were collected. ABO/Rh typing results measured by IH-500 was compared with conventional manual methods. Antibody screening tests were performed with 100 samples using both IH-500 and the Ortho BioVue System, and results were compared. Antibody identification tests were conducted on 5 samples using both IH-500 and the Ortho BioVue System and results were compared. Crossmatching was performed with both IH-500 and conventional manual tube method using 4 patient serum samples and 10 blood cell donors, and 40 results were compared. Isoagglutinin titer of anti-A and anti-B was determined in 10 samples using both IH-500 and the automated analyzer Ortho AutoVue Innova and concordance rates were obtained. The concordance rates of ABO/Rh typing, antibody screening test, antibody identification test, and crossmatching between comparative manual methods and the IH-500 were all 100%. In the evaluation of isoagglutinin titer, 8 (80.0%) results out of 10 samples (80%) showed results within ± 1 titer between the IH-500 and the AutoVue Innova, which indicates the concordance rates of 80.0%. IH-500 reported results with two titers lower than Ortho AutoVue Innova in two samples. The IH-500 demonstrated good concordance rates and provided reliable results compared to comparative manual methods in the blood bank testing. IH-500 would be useful as a possible replacement for conventionally performed manual methods in blood bank testing. © Indian Society of Hematology and Blood Transfusion 2019.

Entities:  

Keywords:  Blood bank testing; Evaluation; IH-500; Performance

Year:  2019        PMID: 31741629      PMCID: PMC6825066          DOI: 10.1007/s12288-019-01127-4

Source DB:  PubMed          Journal:  Indian J Hematol Blood Transfus        ISSN: 0971-4502            Impact factor:   0.900


  14 in total

Review 1.  Laboratory safety aspects of SARS at Biosafety Level 2.

Authors:  T M S Barkham
Journal:  Ann Acad Med Singapore       Date:  2004-03       Impact factor: 2.473

2.  Transfusion safety: what has been done; what is still needed?

Authors:  Michelle R Brown; Margaret G Fritsma; Marisa B Marques
Journal:  MLO Med Lab Obs       Date:  2005-11

3.  Evaluation of two automated instruments for pre-transfusion testing: AutoVue Innova and Techno TwinStation.

Authors:  So Youn Shin; Kye Chul Kwon; Sun Hoe Koo; Jong Woo Park; Chi Seon Ko; Jeong Hoon Song; Ji Youn Sung
Journal:  Korean J Lab Med       Date:  2008-06

4.  Validation of a hospital-laboratory workstation for immunohematologic methods.

Authors:  Helge Schoenfeld; Karin J Pretzel; Christian von Heymann; Bruno Neuner; Ulrich Kalus; Holger Kiesewetter; Axel Pruss
Journal:  Transfusion       Date:  2009-08-26       Impact factor: 3.157

Review 5.  Automation in the transfusion service.

Authors:  S H Butch
Journal:  Immunohematology       Date:  2008

6.  An experience of the introduction of a blood bank automation system (Ortho AutoVue Innova) in a regional acute hospital.

Authors:  Yuk Wah Cheng; Jenny M Wilkinson
Journal:  Transfus Apher Sci       Date:  2015-03-16       Impact factor: 1.764

7.  A fully automated blood typing system for hospital transfusion services. ABS2000 Study Group.

Authors:  S G Sandler; A Langeberg; N Avery; P D Mintz
Journal:  Transfusion       Date:  2000-02       Impact factor: 3.157

8.  A multicenter study on the performance of a fully automated, walk-away high-throughput analyzer for pretransfusion testing in the US population.

Authors:  John D Roback; Sheilagh Barclay; JoAnn M Moulds; Gregory A Denomme
Journal:  Transfusion       Date:  2015-03-09       Impact factor: 3.157

9.  End-to-end electronic control of the hospital transfusion process to increase the safety of blood transfusion: strengths and weaknesses.

Authors:  Amanda Davies; Julie Staves; Jonathan Kay; Angela Casbard; Michael F Murphy
Journal:  Transfusion       Date:  2006-03       Impact factor: 3.157

10.  Economic and workflow analysis of a blood bank automated system.

Authors:  Kyung-Hwa Shin; Hyung Hoi Kim; Chulhun L Chang; Eun Yup Lee
Journal:  Ann Lab Med       Date:  2013-06-24       Impact factor: 3.464

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.