Literature DB >> 31710656

Longevity and marginal bone loss of narrow-diameter implants supporting single crowns: A systematic review.

Lucas Henrique Telles1, Fernando Freitas Portella1,2, Elken Gomes Rivaldo1.   

Abstract

PURPOSE: To compare the longevity and marginal bone loss of narrow-diameter (≤3.3-mm) versus standard-diameter implants supporting single crowns.
MATERIAL AND METHODS: The MEDLINE (via PubMed), Scopus, and SciELO databases were searched for relevant publications. In addition, the scientific references provided by each of the implant companies that appeared in the search were reviewed. Intervention studies comparing longevity and bone loss between narrow-diameter and standard-diameter implants were included.
RESULTS: The search was limited to in vivo studies in humans. The query returned 1931 results, of which 4 met the inclusion criteria. The implant success rate ranged from 93.8% to 100% over a maximum follow-up of 3 years, with no difference between narrow- and standard-diameter implants. Meta-analysis of all included studies showed greater bone loss in narrow-diameter implants as compared with standard ones; however, when analysis was restricted to randomized trials, no such difference was present.
CONCLUSION: The meta-analysis showed no difference in longevity between narrow implants and standard implants when supporting single crowns. However, narrow-diameter implants may be associated with greater marginal bone loss. These findings should be regarded cautiously due to the short follow-up duration and methodological heterogeneity of the primary studies.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31710656      PMCID: PMC6844460          DOI: 10.1371/journal.pone.0225046

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


Introduction

Narrow-diameter implants (<3.3 mm) were designed for edentulous sites with reduced mesiodistal space, such as mandibular central and lateral incisors, as well as maxillary lateral incisors. The current literature supports their extended use in other clinical situations as well, such as narrow alveolar ridges, to prevent preoperative or intraoperative bone reconstruction [1,2] (which increase treatment cost and duration [3,4]) and to reduce postoperative morbidity. However, commercially pure titanium (cpTi) has limited mechanical strength, which led to the hypothesis that the use of narrow-diameter implants could pose a risk of fracture of the implant body [5,6]. Advances in biomaterials led to the development of alloys with increasing fracture and fatigue resistance, such as an alloy of titanium and zirconium (83–87% titanium added to 13–17% zirconium [7]). Biomechanical assays of this alloy in experimental models demonstrated increased resistance to the stresses generated by occlusal loading compared to cpTi [3], even at smaller-than-conventional diameters. Observational studies have shown that narrow-diameter implants have comparable longevity to standard implants [8,9]. In addition, when the longevity of narrow-diameter and standard implants was compared, that of implants with a diameter of 3.0–3.25 mm was found not to differ from that of standard-diameter implants [4,10]. Nonetheless, this finding is based predominantly on observational studies, and does not distinguish between different types of prosthetics supported by these implants. Thus, it does not answer the question of whether practitioners can choose to place narrow-diameter implants instead of conventional ones for the rehabilitation of single missing teeth. Furthermore, there is no consensus on the influence of implant diameter on marginal bone loss. The present review focused on a problem not previously addressed in the literature: narrow-diameter implants (those implants with a diameter of 3.3 mm or less) supporting only single crowns. Within this context, the present systematic review was designed to compare longevity and marginal bone loss between narrow-diameter and standard-diameter implants supporting single crowns.

Methods

The present systematic review was registered in the PROSPERO platform (CRD42018117261) and reported in accordance with the PRISMA statement [11]. The guiding research question for this study was “Is there a difference in longevity and marginal bone loss between narrow-diameter and standard-diameter implants when supporting single crowns in healthy patients?”. In PICO format, this question may be phrased as follows: P–healthy patients; I–implants supporting single crowns; C–narrow-diameter versus standard-diameter implants; O–longevity of implant and marginal bone loss.

Eligibility criteria

Publications that met the following eligibility criteria were included: intervention studies in humans which evaluated the longevity of implants retaining single crowns; observational prospective studies were not included. with at least one group of patients which received narrow-diameter implants and one group which received standard-diameter implants, with a minimum of 10 participants in each group; which reported implant longevity over a follow-up period of at least 1 year. There were no restrictions on language or date of publication.

Sources and search strategy

The MEDLINE (via PubMed), Scopus, and SciELO databases were searched through December 2018. The search strategy for each database is described below. PubMed: (("dental implant" OR "dental implants" OR "narrow implant" OR "narrow implants" OR "narrow-diameter implant" OR "narrow-diameter implants")) AND (longevity OR survival OR “follow-up” OR success)) AND ("randomized controlled trial" OR RCT OR "clinical study" OR trial OR “clinical research” OR “longitudinal study” OR “cohort study” OR practice-based); Scopus: (TITLE-ABS-KEY ("dental implant" OR "dental implants" OR "narrow implant" OR "narrow implants" OR "narrow-diameter implant" OR "narrow-diameter implants") AND TITLE-ABS-KEY (longevity OR survival OR "follow-up" OR success) AND TITLE-ABS-KEY ("randomized controlled trial" OR rct OR "clinical study" OR trial OR "clinical research" OR "longitudinal study" OR "cohort study" OR practice-based)); SciELO: “dental implants”; In addition to the aforementioned electronic databases, the scientific literature recommended by implant manufacturers as a reference on their products was also reviewed. The following manufacturers were included: Straumann (Switzerland), Nobel Biocare (Switzerland), Biohorizons (USA), Z-systems (Germany), Dentsply (USA), 3i (USA), and Dentatus (Sweden).

Study selection and data collection process

The article lists retrieved by each search strategy were unified and duplicate entries removed. For study selection, two investigators (LHT and EGR) evaluated the titles and abstracts separately. Those considered ineligible by both reviewers were excluded outright; those considered ineligible by one reviewer but eligible by the other were retained for full-text reading. All studies not excluded were read in full by two investigators working together (LHT and FFP), who then selected those that fully met the eligibility criteria and performed data extraction. At this time, the authors also performed the risk of bias analysis. Patient-related and procedure-related data were collected, as were the outcomes of interest (longevity and marginal bone loss). Longevity was determined by the percentage of implants considered successful at the latest recorded time point of clinical evaluation. Implants were considered successful when they were osseointegrated and remained functional. Marginal bone loss data were collected when assessed by radiographic examination; mean values for implant sites were calculated for analysis. To perform sensitivity analysis, the number of implants that were not followed in each experimental group was recorded, and longevity was then recalculated. When more than one publication was derived from a single study, with different follow-up periods for the same sample, data from all publications referring to the same study were pooled and the publication with the longest duration of follow-up was recorded in the table.

Risk of bias in individual studies

Studies were assessed for risk of bias as recommended in the Cochrane Handbook of Systematic Reviews of Interventions. The possibility of conflict of interest with implant manufacturers was also considered and recorded.

Data synthesis and analysis

Implant longevity was recorded as the number of successful cases followed in relation to the total number of cases in each group. Marginal bone loss around the implant head was extracted in mm for each of the experimental groups. The outcomes of the included articles were pooled for meta-analysis to determine the overall estimated effects of each outcome based on a random effects model. For analysis of longevity, the Mantel-Haenszel method was applied to calculate the risk ratio for success, while for marginal bone loss, the overall mean difference was calculated. Statistical analysis was performed in RevMan 5.3 software (The Cochrane Collaboration). Significance was accepted at the 5% level.

Results

Study selection

Fig 1 provides a flow diagram of study selection. The database search (PubMed, Scopus, and SciELO) retrieved 6,402 articles. A hand search of the reference lists provided by manufacturers yielded a further 1,677. After exclusion of duplicate entries, 1,931 papers remained. Of these, 1,819 were excluded after analysis of titles and abstracts. Thus, 112 articles were read in full. None of these was found only on manufacturers’ reference lists. After full-text reading, 107 papers were removed for failure to meet the eligibility criteria. Of the 5 eligible articles remaining, two were from the same study, but with different follow-up times [8,12]). The 4 remaining articles were included in the meta-analysis (Table 1).
Fig 1

Flow diagram of study selection.

Table 1

Characteristics of the studies and detailed description of comparison groups.

StudyAndersen (2001) [4]Santing (2013) [14]Ioannidis (2015) [8,12]de Souza (2018) [13]
NarrowStandardNarrowStandardNarrowStandardNarrowStandard
No. patients2827124820202222
Mean age (years)23.223.036.9Not reported53.4
No. implants3228124820202222
Diameter3.253.753.34.13.34.13.34.1
Length13 and 1513 and 1512 and 1412 and 14≥8≥86 to 128 to 10
Implant siteAnterior maxillaAnterior maxillaAnterior or posterior, maxilla or mandiblePosterior, maxilla or mandible
Manufacturer3i (2-piece)Straumann (2-piece)Straumann (2-piece)Straumann (2-piece)
Platform typePlatform matchingPlatform switchingPlatform switchingPlatform matching
Apical-coronal implant positionBone levelBone levelBone levelTissue level
Implant materialTitaniumTitanium- Zirconium /TitaniumTitanium- Zirconium /TitaniumTitanium- Zirconium /Titanium
Surface treatmentNoYesYesYes
Time to loading6 months3 months3 monthsNot reported
Duration of follow-up3 years1.5 year3 years3 years
Success rate at latest follow-up93.8%100%100%100%100%100%95.4%100%
Outcome of followed implants27 successful, 3 lost to follow-up26 successful, 2 lost to follow-upAll 12 successfulAll 48 successful17 successful, 3 lost to follow-up15 successful, 5 lost to follow-up19 successful, 2 lost to follow-up, 1 failed20 successful, 2 lost to follow-up
Radiographic marginal bone loss (mm)0.52±0.010.40±0.16Not reported0.40±0.930.31±0.590.58±0.390.53±0.46

Study characteristics

De Souza et al [13]. conducted a split-mouth randomized clinical trial in which patients received Tissue Level implants (Straumann, Switzerland) with a diameter of 3.3 mm at one site and 4.1 mm in another. Each patient received at least one implant of each diameter in the maxilla or mandible, for a total of 44 implants placed (22 narrow and 22 standard). Periapical radiographs were performed on the day of placement and at 1-year and 3-year follow-up. The authors found no significant differences in marginal bone loss at any of the three follow-up time points (immediate, 1 year, and 3 years). After 3 years of follow-up, the success rate was 100% for standard-diameter implants and 95.4% for narrow-diameter implants. One implant presented a pocket depth >5 mm, with bleeding on probing and suppuration. Nevertheless, the implant remained in position and functional, for a 100% survival rate in the narrow-diameter group. Santing et al [14] carried out a prospective intervention study using Bone Level implants (Straumann, Switzerland) for single-tooth replacement in the maxilla. Sixty patients participated in the study, with each receiving a 3.3-mm (narrow) or 4.1-mm (standard) implant. Overall, 12 narrow and 48 standard implants were placed. The authors compared bone loss on periapical radiographs between implants placed in augmented sites and those placed in native bone. There was no significant difference between groups, with a 100% survival rate at a maximum follow-up time of 18 months. In a randomized clinical trial, Ioannidis et al [8,12] sought to compare loss of marginal bone level with 3.3-mm versus 4.1-mm implants. Implants in the experiment group (n = 20) were made from a Ti-Zr alloy, while those in the control group (n = 20) used conventional titanium alloys. The implants were placed randomly at sites requiring single tooth replacement, at any location in the maxilla or mandible, and were followed for up to 3 years. At 1-year follow-up, all evaluated implants were in place and stable; two participants in the control group were subsequently lost to follow-up. At the end of follow-up, 32 of the 40 included patients were examined (15 control, 17 experiment). The other 8 patients were lost to follow-up. According to the authors, there were no implant failures, giving a 100% survival rate for both groups over 3 years (among the implants examined at final follow-up). A clinical trial by Andersen et al.[4] included 55 patients requiring single-tooth replacements in the anterior region of the maxilla. Of these, 27 received 28 standard implants (diameter 3.75 mm), and 28 patients received 32 narrow implants (diameter 3.25 mm). Two implants in the narrow-diameter group were lost (93.8% survival rate), versus none in the standard group (100%).

Synthesis of results

A meta-analysis considering those intervention studies (Fig 2) that allowed comparison of longevity between narrow and standard implants showed no difference between them (RR 0.98 [0.90, 1.07]). A sensitivity analysis including only the RCT (Fig 3) showed a similar risk ratio for success among distinct diameters, with a slight increase in the 95% confidence interval (RR 1.00 [0.84, 1.20]).
Fig 2

Forest plot of all intervention studies comparing the longevity of narrow and standard implants.

Fig 3

Forest plot of randomized clinical trials comparing the longevity of narrow and standard implants.

Narrow implants were associated with greater marginal bone loss, with a mean 0.12 (0.06 to 0.18) mm of additional loss compared to standard implants (Fig 4). This difference did not remain when only RCTs were included in the meta-analysis (Fig 5), the mean difference in bone loss then being 0.06 (-0.18 to 0.30) mm.
Fig 4

Forest plot of all intervention studies comparing marginal bone loss between narrow and standard implants.

Fig 5

Forest plot of randomized clinical trials comparing marginal bone loss between narrow and standard implants.

Risk of bias

Fig 6 summarizes the analysis of risk of bias in the included studies. None of the studies included all of the quality categories evaluated; blinding of assessors and patients was most often neglected. Three of the four studies had some form of relationship with the industry. Funnel plots analyses showed a low risk of publication bias, while the I2 value of 0% was consistent with absence of statistical heterogeneity among studies, both for longevity and for marginal bone loss.
Fig 6

Risk of bias of included studies.

Discussion

The present literature review and meta-analysis was designed to help dental practitioners decide which implant diameter to choose in settings that would allow placement of both narrow-diameter and standard implants to support single crowns. Despite the short follow-up period of 3 years or less, longevity was shown not to differ between diameters. However, narrow-diameter implants may be associated with greater marginal bone loss—0.12 (0.06–0.18) mm greater at 3-year follow-up. It bears stressing that the evaluation of implant success goes beyond longevity. Several extrinsic and intrinsic variables may be implicated in peri-implant marginal bone loss. Factors related to the implant itself include its geometry, dimensions and interface between the prosthetic abutment and the implant, the three-dimensional position of the implant, and its angle. Patient-related factors include the quantity and quality of hard and soft tissue surrounding the implant, which are involved in maintaining the biological distances between tooth and implant and from implant to implant [1]. The amount of bone tissue surrounding a narrow-diameter implant was likely to be smaller than when placing a standard implant in the non-randomized studies included in this systematic review. This would justify the greater marginal bone loss with narrow-diameter implants. A randomized clinical trial comparing the amount of peri-implant bone through postoperative CBCT could provide further evidence to support or refute this assumption. In addition to implant diameter, the type of platform and the position of the implant-abutment junction [15] can also influence marginal bone loss. A systematic review comparing marginal bone loss with platform-switching versus platform-matching implants, which pooled the outcomes of 15 publications with data from 642 patients followed up for 1 year, suggested greater bone loss with platform matching [16]. Among the three studies included in the analysis of marginal bone loss in this review, Andersen [4] reported higher values for narrow implants, which accounted for the statistical difference observed in the meta-analysis that included all eligible intervention studies. A stratified analysis, evaluating the joint effect of implant diameter and of different implant platforms and apicocoronal positions, is necessary for a better understanding of the factors associated with marginal bone loss. The included studies reported on implants placed in different regions of the oral cavity. Santing et al. [14] reported on implants placed in the anterior and first premolar regions, while de Souza et al. [13] placed implants only in the posterior region. Ioannidis et al [8,12] placed implants in the anterior and premolar area, and Andersen et al. [4], in the anterior maxilla. This variability hindered analysis of the potential impact of implant location. Another aspect to be considered in the data analysis is the reason for tooth loss. Of the articles included in this review, only Santing et al. reported this information; the most frequent cause in their series was tooth fracture (n = 29), followed by endodontic failure (n = 19), root resorption (n = 5), periodontal disease (n = 4) and agenesis (n = 3). Andersen et al. [4] performed immediate provisionalization in the narrow implants. Although there is concern about the incidence of masticatory forces on the implants immediately after placement, clinical maneuvers to minimize osseointegration failure and marginal bone loss may be employed regardless of implant diameter [17]. These unique characteristics of the different included studies should be considered when analyzing the results of this meta-analysis. Longevity or success can be assessed from several aspects [18]. In this review, the criteria for implant longevity were osseointegration and preserved function at clinical evaluation. Implant failures reported in primary studies occur most often in the earliest stage of follow-up (first 6 months), mainly during the process of osseointegration. After this initial period, there were practically no implant failures. However, the narrow implants were associated with greater marginal bone loss, which clinically, in the long term, may represent a concern to the clinician, considering the possibility of cosmetic issues such as retraction of the peri-implant mucosa due to decreased bone support, as well as facilitating the development of peri-implantitis [19]. A previous systematic review with meta-analysis published addressing the comparison narrow-diameter (≤3.3-mm) versus standard-diameter implants [20,21]. In general, these studies showed no difference in longevity and marginal bone loss between diameters. These previous studies grouped implants without distinction as to the type of prosthesis supported. Their survival data were also mixed, referring to narrow implants rehabilitating fully edentulous arches (i.e., supporting removable or fixed complete dentures), as well as partially edentulous ones (supporting removable partial dentures, fixed partial dentures, and single crowns). Furthermore, observational studies were grouped with interventional studies. The decision to limit this systematic review to implants of 3.3 mm or narrower diameter and supporting single crowns only aimed to present clinicians with data on the survival of these biomaterials, which provide advantages such as less need for alveolar ridge augmentation prior to implant placement, less need for orthodontic movement to recover reduced prosthetic spaces, and improved aesthetic outcomes in the anterior zone [22] enhancing the quality of peri-implant tissues. Another, more recent review [23] also focused on studies of narrow implants, comparing these with standard-diameter implants, and including subgroup analyses stratified by diameter (<3 mm, <3.0–3.25 mm, and 3.3–3.5 mm). This review found that the longevity of implants less than 3.0 mm in diameter was shorter than that of standard implants. However, this review also failed to discriminate between implants as to the type of prosthesis supported (single or multiple, fixed or removable). Non-splinted implants are subject to greater overload than those splinted by prosthetic structures [24]. Furthermore, we present a meta-analysis of marginal bone loss. We chose to conduct our analysis considering implants lost to follow-up as failures and then recalculate longevity, in order to complete a sensitivity analysis, seeking to attenuate any reporting bias. However, considering the longevity reported by the authors of the primary studies, without sensitivity analysis, the effect size measures of the meta-analyses would remain similar, with a risk ratio for success of narrow implants of 0.98 [0.92, 1.03]. Such sensitivity analyses are of the utmost importance when studying treatment longevity, since patient losses to follow-up can have a significant impact on estimated longevity. Considering the success rate of narrow-diameter implants in observational studies, a sensitivity analysis considering losses to follow-up might reduce success rates from nearly 100% to less than 90% [4,12,13,25]. The studies were heterogeneous, with differences in design, implant manufacturers, implant sites (anterior versus posterior, maxilla versus mandible), implant diameters compared, and time to implant loading. It is plausible that some difference in implant longevity would exist as a result of certain variables; however, we were unable to isolate these. In addition, quality evaluation of the studies revealed potential risk of bias, due to issues such as inadequate randomization, absence of allocation concealment or assessor blinding, and industry involvement in all included studies. Due to the inclusion criteria adopted, which restricted the review to intervention studies (not necessarily randomized clinical trials), the absence of random allocation was expected. The selection bias caused by the inclusion of non-randomized studies, besides the methodological heterogeneity of the studies, means that caution is warranted when translating the results of this review into clinical practice. One example is analysis of marginal bone loss, the results of which differed when all studies were included and when analysis was restricted to RCTs. We decided to include non-randomized intervention studies because of the nature of the research question. It was expected that, in primary studies, allocation of patients into the narrow-diameter and standard-diameter groups would occur according to the characteristics of the enrolled patients, such as the space available for prosthetic rehabilitation, and not by randomization. Thus, the presence of non-randomized comparative studies was expected, and their inclusion allowed us to better answer our research question in this poorly studied context. Nevertheless, on meta-analysis, no evidence of statistical heterogeneity was observed (I2 = 0.00), thus allowing the data to be compiled for analysis. Incorrect three-dimensional positioning of the implant in the alveolar ridge can lead to physiological bone loss. The coronal portion of bone tends to undergo resorption if the implant is placed too close to neighboring teeth, to other implants, or to a very thin bony wall, as is usually the case with the buccal bone plate [16]. This would justify the practitioner’s decision to place an implant with a narrower diameter, in an attempt to maintain a thicker portion of bone tissue around the implant or avoid undue proximity to neighboring teeth or appliances, in order to minimize or mitigate unnecessary resorption. The meta-analysis showed no difference in longevity between narrow implants and standard implants when supporting single crowns. However, narrow-diameter implants may be associated with greater marginal bone loss. These findings should be regarded cautiously, due to the short follow-up duration and methodological heterogeneity of the primary studies. Further studies should address these aspects in greater detail. (PDF) Click here for additional data file. 26 Sep 2019 PONE-D-19-22348 Longevity and marginal bone loss of narrow-diameter implants supporting single crowns: a systematic review PLOS ONE Dear Prof. Portella, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. The reviewers and editor in general were please with the manuscript. However, there is an important issue of lack of included studies. It is therefore important to carefully discuss the papers excluded that might have some insight into the topics. Please include these important excluded articles in the Discussion. Also, please expand the limitations and how you might overcome this in the future. We would appreciate receiving your revised manuscript by Nov 10 2019 11:59PM. When you are ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. To enhance the reproducibility of your results, we recommend that if applicable you deposit your laboratory protocols in protocols.io, where a protocol can be assigned its own identifier (DOI) such that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols Please include the following items when submitting your revised manuscript: A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). This letter should be uploaded as separate file and labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. This file should be uploaded as separate file and labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. This file should be uploaded as separate file and labeled 'Manuscript'. Please note while forming your response, if your article is accepted, you may have the opportunity to make the peer review history publicly available. The record will include editor decision letters (with reviews) and your responses to reviewer comments. If eligible, we will contact you to opt in or out. We look forward to receiving your revised manuscript. Kind regards, Sompop Bencharit, DDS, MS, PhD, FACP Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at http://www.journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and http://www.journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf 2. Thank you for stating the following financial disclosure: "The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript." Please provide an amended Funding Statement that declares *all* the funding or sources of support received during this specific study (whether external or internal to your organization) as detailed online in our guide for authors at http://journals.plos.org/plosone/s/submit-now. Please state what role the funders took in the study.  If any authors received a salary from any of your funders, please state which authors and which funder. If the funders had no role, please state: "The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript." Please include your amended statements within your cover letter; we will change the online submission form on your behalf. 3. Please include captions for your Supporting Information files at the end of your manuscript, and update any in-text citations to match accordingly. Please see our Supporting Information guidelines for more information: http://journals.plos.org/plosone/s/supporting-information. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Yes ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: In this systematic review with meta-analysis, Telles et al. compared marginal bone loss and longevity around narrow- and standard-diameter implants supporting single crowns. Four studies were included in the quantitative review. Authors observed no significant difference between groups for longevity. They observed more marginal bone loss around narrow implants after up to 3 years follow-up. Nevertheless, there was no significant difference when limiting the analyses to RCTs only. This is a nice paper dealing with a topic of main clinical importance. Few studies were included in the review, due to paucity of available data. Please find below my comments : Introduction : Last sentence : please (1) change ‘the present study’ with ‘the present systematic review’ and (2) add ‘supporting single crowns’, which is the strenth of the present paper. Methods : Authors declared propspective studies were excluded, but Santing et al. was declared in the manuscript as a prospective study (p8). Also, looking at references, Santing et al. study looks to be Hendrick et al. study. Authors included scientific literature recommended by implant manufacturers, which exposed them to bias of sponsorship. Also, did the authors perform an electronic seach in EMBASE ? Authors should use the Kappa statistic to assess interrater reliability between reviewers. Results : Line 190 : Andersen is a clinical trial, not a randomized clinical trial. What about the fifth study (Gi et al.) ? It is a duplicate with Ionnidis et al, but because this study was indicated in the qualitative analysis (Figure 1), 1-year follow-up data should be indicated in both manuscript and Table 1. Please have a look on success rates for Santing et al. and De Souza et al. studies. Data indicated in the manuscript differ from those indicated in Table 1. Discussion : First sentence : please indicate that the review included only studies with implants supporting single crowns (this is a strength). Line 240 : Unless I misunderstood, for a same initial bone volume, bone tissue surrounding a narrow diameter implant is greater around a standard diameter implant, because the implant diameter is lower. Among the three studies which compared marginal bone loss around narrow- and standard-diameter implants, one study used immediate provisionalization (Andersen et al.), whereas the others did not. This immediate functionnal loading is associated with occlusal forces which are directed along the long axis of the implant body. The resulting contact pressure at the implant-bone interface may interfere with osseointegration. Because the lower the surface is, the higher the pressure is, authors may also hypothesize that higher contact pressure at the implant-bone interface for immediate provisionalized narrow diameter implants results in higher marginal bone loss. Tables and figures : Figure 1 : Please have a look on the number of ‘records identified through database searching’ and the number of ‘additional records identified through hand search of reference lists’. When looking to the number of duplicates, it suppose that nearly all studies were identified through the four sources (Pubmed, Scopus, Scielo and hand search), which is very very surprising. Table 1 : Please indicate references numbers. For Santing et al (2012) study, Table 1 indicates 10 narrow diameter implants whereas manuscript indicates 12 narrow diameter implants. Reviewer #2: This manuscript reviews the success and bone loss around narrow diameter implants. The introduction is well structured and prevents the case for this review well. Methods are appropriate and well documented. What is called "success" is actually survival. Some assessment of clinical parameters would be good or using previous criteria such as Karoussis 2003/2004. It's not a surprise only 4 papers could be included. Since the authors make the comments about the implant material, I feel this should be included in Table 1. Is it possible to undertake more analysis of the where the implants were placed. I would think it would be more anteriorly. What was the effect of position on the bone loss? Do posterior narrow implants have more bone loss? Is there any information on why the natural teeth were lost? Was it Perio, caries, trauma, etc. If it's Perio then this may account for the higher bone loss? Discussion is appropriate for the results. References appropriate and up to date. ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: No [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files to be viewed.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email us at figures@plos.org. Please note that Supporting Information files do not need this step. 23 Oct 2019 Dear Professor Sompop Bencharit Academic Editor, PLOS ONE On behalf of my coauthors, I would like to thank you for the time spent in reviewing our manuscript “Longevity and marginal bone loss of narrow-diameter implants supporting single crowns: a systematic review” (PONE-D-19-22348). We reiterate our wish to publish in PLOS ONE. Please find a point-by-point response to the reviewers’ comments below, in italic. Changes to the manuscript are highlighted in yellow. Reviewer #1 In this systematic review with meta-analysis, Telles et al. compared marginal bone loss and longevity around narrow- and standard-diameter implants supporting single crowns. Four studies were included in the quantitative review. Authors observed no significant difference between groups for longevity. They observed more marginal bone loss around narrow implants after up to 3 years follow-up. Nevertheless, there was no significant difference when limiting the analyses to RCTs only. This is a nice paper dealing with a topic of main clinical importance. Few studies were included in the review, due to paucity of available data. Please find below my comments : Introduction : Last sentence : please (1) change ‘the present study’ with ‘the present systematic review’ and (2) add ‘supporting single crowns’, which is the strenth of the present paper. We thank the reviewer for this assessment of our research, and for the time devoted to reviewing our manuscript. We believe these comments and suggestions substantially improved the quality of our work. Methods : Authors declared propspective studies were excluded, but Santing et al. was declared in the manuscript as a prospective study (p8). Also, looking at references, Santing et al. study looks to be Hendrick et al. study. Thank you for this observation. Indeed, prospective observational studies were excluded. Santing et al. presented prospective data of an interventional study. Santing et al. and Hendrick et al. represent the same article; this was an error made during reference formatting. We apologize, and have double-checked all references. Authors included scientific literature recommended by implant manufacturers, which exposed them to bias of sponsorship. Also, did the authors perform an electronic seach in EMBASE ? We agree that selection bias can be an issue when citing literature recommended by the implant industry. However, all of the included articles retrieved from these lists were also found by our electronic database search. For the sake of transparency, a sentence stating that none of the included articles was retrieved solely from manufacturers’ lists has been added to the manuscript. We also considered sponsorship bias in the Risk of bias analysis. EMBASE was not searched. Authors should use the Kappa statistic to assess interrater reliability between reviewers. The concern regard reliability between reviewers is important. We did not calculate the Kappa statistic because: - For an article to be excluded during the title/abstract review stage, both reviewers were required to classify the paper as ineligible; if they disagreed, the paper was read in full; - Full-text reading: evaluation for eligibility and data extraction was performed together. During this process, no article gave rise to any debate or disagreement. Results : Line 190 : Andersen is a clinical trial, not a randomized clinical trial. Thank you for noting. We have corrected this sentence. What about the fifth study (Gi et al.) ? It is a duplicate with Ionnidis et al, but because this study was indicated in the qualitative analysis (Figure 1), 1-year follow-up data should be indicated in both manuscript and Table 1. Information regarding 1-year follow-up has been added to the manuscript. Please have a look on success rates for Santing et al. and De Souza et al. studies. Data indicated in the manuscript differ from those indicated in Table 1. We apologize for this error. The values in Table 1 have been corrected. Discussion : First sentence : please indicate that the review included only studies with implants supporting single crowns (this is a strength). Grateful for the tip. The sentence has been rephrased. Line 240 : Unless I misunderstood, for a same initial bone volume, bone tissue surrounding a narrow diameter implant is greater around a standard diameter implant, because the implant diameter is lower. We agree with the reviewer. This paragraph has been reviewed. Among the three studies which compared marginal bone loss around narrow- and standard-diameter implants, one study used immediate provisionalization (Andersen et al.), whereas the others did not. This immediate functionnal loading is associated with occlusal forces which are directed along the long axis of the implant body. The resulting contact pressure at the implant-bone interface may interfere with osseointegration. Because the lower the surface is, the higher the pressure is, authors may also hypothesize that higher contact pressure at the implant-bone interface for immediate provisionalized narrow diameter implants results in higher marginal bone loss. Thank you for this observation. We have added a paragraph to discussion to address this issue. Tables and figures : Figure 1 : Please have a look on the number of ‘records identified through database searching’ and the number of ‘additional records identified through hand search of reference lists’. When looking to the number of duplicates, it suppose that nearly all studies were identified through the four sources (Pubmed, Scopus, Scielo and hand search), which is very very surprising. This is a valid point. Indeed, almost of the papers identified through hand searching were also found in the electronic databases. Table 1 : Please indicate references numbers. For Santing et al (2012) study, Table 1 indicates 10 narrow diameter implants whereas manuscript indicates 12 narrow diameter implants. Grateful for the observation. Reference numbers are now cited in the Table, and the number of narrow implants in the Santing study has been corrected. Reviewer #2: This manuscript reviews the success and bone loss around narrow diameter implants. The introduction is well structured and prevents the case for this review well. Methods are appropriate and well documented. What is called "success" is actually survival. Some assessment of clinical parameters would be good or using previous criteria such as Karoussis 2003/2004. We agree with the reviewer regarding the definition of implant outcomes. However, due to the short follow-up of primary studies (up to 3 years), we chose to term the analysed outcome “success”, not survival, and stated in the Methods section the definition adopted: “Implants were considered successful when they were osseointegrated and remained functional”. It's not a surprise only 4 papers could be included. Since the authors make the comments about the implant material, I feel this should be included in Table 1. Thank you for your assessment. This is important information and has been added to Table 1. Is it possible to undertake more analysis of the where the implants were placed. I would think it would be more anteriorly. What was the effect of position on the bone loss? Do posterior narrow implants have more bone loss? The region of implant placement is extremely relevant. Unfortunately, variability across studies precluded a more in-depth analysis. We have discussed this issue in greater depth now. Is there any information on why the natural teeth were lost? Was it Perio, caries, trauma, etc. If it's Perio then this may account for the higher bone loss? Information and discussion regarding this issue was considered during manuscript review. A paragraph to this effect has been added. Discussion is appropriate for the results. References appropriate and up to date. Once again, we would like to thank the Editor and the Reviewers for the important suggestions and constructive criticism. We believe the quality of the paper has improved significantly as a result. Thank you for your consideration. Sincerely, Fernando Freitas Portella (on behalf of all authors) Submitted filename: Response to Reviewers.docx Click here for additional data file. 29 Oct 2019 Longevity and marginal bone loss of narrow-diameter implants supporting single crowns: a systematic review PONE-D-19-22348R1 Dear Dr. Portella, We are pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it complies with all outstanding technical requirements. Within one week, you will receive an e-mail containing information on the amendments required prior to publication. When all required modifications have been addressed, you will receive a formal acceptance letter and your manuscript will proceed to our production department and be scheduled for publication. Shortly after the formal acceptance letter is sent, an invoice for payment will follow. To ensure an efficient production and billing process, please log into Editorial Manager at https://www.editorialmanager.com/pone/, click the "Update My Information" link at the top of the page, and update your user information. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to enable them to help maximize its impact. If they will be preparing press materials for this manuscript, you must inform our press team as soon as possible and no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. With kind regards, Sompop Bencharit, DDS, MS, PhD, FACP Academic Editor PLOS ONE Additional Editor Comments (optional): The authors had sufficiently addressed all comments from the reviewers. Thank you for the revision. Reviewers' comments: 1 Nov 2019 PONE-D-19-22348R1 Longevity and marginal bone loss of narrow-diameter implants supporting single crowns: a systematic review Dear Dr. Portella: I am pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please notify them about your upcoming paper at this point, to enable them to help maximize its impact. If they will be preparing press materials for this manuscript, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. For any other questions or concerns, please email plosone@plos.org. Thank you for submitting your work to PLOS ONE. With kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Sompop Bencharit Academic Editor PLOS ONE
  25 in total

1.  A prospective clinical study evaluating the safety and effectiveness of narrow-diameter threaded implants in the anterior region of the maxilla.

Authors:  E Andersen; E Saxegaard; B M Knutsen; H R Haanaes
Journal:  Int J Oral Maxillofac Implants       Date:  2001 Mar-Apr       Impact factor: 2.804

Review 2.  Bone level changes around platform switching and platform matching implants: a systematic review with meta-analysis.

Authors:  M DI Girolamo; R Calcaterra; R DI Gianfilippo; C Arcuri; L Baggi
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

3.  Consensus statements and recommended clinical procedures regarding loading protocols.

Authors:  Hans-Peter Weber; Dean Morton; German O Gallucci; Mario Roccuzzo; Luca Cordaro; Linda Grutter
Journal:  Int J Oral Maxillofac Implants       Date:  2009       Impact factor: 2.804

4.  Comparison of survival rate and crestal bone loss of narrow diameter dental implants versus regular dental implants: A systematic review and meta-analysis.

Authors:  Mohammed Alrabiah
Journal:  J Investig Clin Dent       Date:  2018-11-09

5.  Clinical and Radiographic Evaluation of a Small-Diameter Dental Implant Used for the Restoration of Patients with Permanent Tooth Agenesis (Hypodontia) in the Maxillary Lateral Incisor and Mandibular Incisor Regions: A 36-Month Follow-Up.

Authors:  Paul King; Carlo Maiorana; Ralph G Luthardt; Katarina Sondell; Jesper Øland; Pablo Galindo-Moreno; Peter Nilsson
Journal:  Int J Prosthodont       Date:  2016 Mar-Apr       Impact factor: 1.681

6.  Clinical and radiographic evaluation of early loaded narrow-diameter implants: 5-year follow-up of a multicenter prospective clinical study.

Authors:  Pablo Galindo-Moreno; Peter Nilsson; Paul King; Nils Worsaae; Alexander Schramm; Miguel Padial-Molina; Carlo Maiorana
Journal:  Clin Oral Implants Res       Date:  2017-06-18       Impact factor: 5.977

7.  Clinical evaluation of small-diameter implants in single-tooth and multiple-implant restorations: a 7-year retrospective study.

Authors:  Paolo Vigolo; Andrea Givani; Zeina Majzoub; Giampiero Cordioli
Journal:  Int J Oral Maxillofac Implants       Date:  2004 Sep-Oct       Impact factor: 2.804

8.  Retrospective multicenter evaluation of tapered implant with a sandblasted and acid-etched surface at 1 to 4 years of function.

Authors:  Min-Su Bae; Dong-Seok Sohn; Mi-Ra Ahn; Hyun-Woo Lee; Heui-Seung Jung; Im-Hee Shin
Journal:  Implant Dent       Date:  2011-08       Impact factor: 2.454

9.  Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 3-year results of a randomized controlled clinical study.

Authors:  Alexis Ioannidis; German O Gallucci; Ronald E Jung; Sary Borzangy; Christoph H F Hämmerle; Goran I Benic
Journal:  J Clin Periodontol       Date:  2015-11-14       Impact factor: 8.728

Review 10.  Systematic review on success of narrow-diameter dental implants.

Authors:  Marc O Klein; Eik Schiegnitz; Bilal Al-Nawas
Journal:  Int J Oral Maxillofac Implants       Date:  2014       Impact factor: 2.804

View more
  1 in total

1.  One-year performance of posterior narrow diameter implants in hyperglycemic and normo-glycemic patients-a pilot study.

Authors:  Anton Friedmann; Marianna Winkler; Daniel Diehl; Mehmet Selim Yildiz; Hakan Bilhan
Journal:  Clin Oral Investig       Date:  2021-05-03       Impact factor: 3.573

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.