Literature DB >> 26440201

Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 3-year results of a randomized controlled clinical study.

Alexis Ioannidis1, German O Gallucci2, Ronald E Jung1, Sary Borzangy2,3, Christoph H F Hämmerle1, Goran I Benic1.   

Abstract

AIM: To test whether titanium-zirconium (Ti-Zr) 3.3 mm diameter implants perform differently from titanium (Ti) 4.1 mm diameter implants with respect to marginal bone level (MBL) and clinical parameters.
MATERIAL AND METHODS: Forty patients in need of a single-implant crown in the anterior or premolar regions were enrolled in two centres. Following random allocation, either a Ti-Zr or a Ti implant was inserted. Porcelain-fused-to-metal crowns were inserted 6 months after implantation. Implant survival, change in MBL, clinical parameters, change in mid-facial mucosa and papilla levels, and the occurrence of biological and technical complications were assessed at the 3-year follow-up.
RESULTS: At 3 years, 32 of the 40 included patients were examined (15 Ti and 17 Ti-Zr implants). There were no implant failures. From the implant placement to 3 years, the median change in mean MBL amounted to 0.21 mm (mean: -0.31) in the Ti group and 0.10 mm (mean: -0.40) in the Ti-Zr group. There were no significant differences between the groups with respect to the change in MBL, the change in mucosa levels, and the occurrence of complications.
CONCLUSIONS: Ti-Zr implants with 3.3 mm diameter used for the support of single crowns in the anterior and the premolar regions did not differ from Ti implants with 4.1 mm diameter regarding the clinical performance over a 3-year period.
© 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  bone; complication; crown; dental implants; diameter; fixed partial denture; humans; mucosa; narrow; peri-implantitis; radiographic; randomized controlled trial; survival; titanium; titanium-zirconium

Mesh:

Substances:

Year:  2015        PMID: 26440201     DOI: 10.1111/jcpe.12468

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  9 in total

1.  Mechanical stability of angulated zirconia abutments supporting maxillary anterior single crowns on narrow-diameter implants.

Authors:  Ruiyang Ma; Ping Yu; Yuqiang Zhang; Chenyang Xie; Xin Tan; Jikui Sun; Haiyang Yu
Journal:  Clin Oral Investig       Date:  2022-09-26       Impact factor: 3.606

Review 2.  Clinical Performance Comparing Titanium and Titanium-Zirconium or Zirconia Dental Implants: A Systematic Review of Randomized Controlled Trials.

Authors:  Paulo Rafael Esteves Fernandes; Ada Isis Pelaez Otero; Juliana Campos Hasse Fernandes; Leonardo Mohamad Nassani; Rogerio Moraes Castilho; Gustavo Vicentis de Oliveira Fernandes
Journal:  Dent J (Basel)       Date:  2022-05-12

Review 3.  Retention failures in cement- and screw-retained fixed restorations on dental implants in partially edentulous arches: A systematic review with meta-analysis.

Authors:  Jatin K Jain; Rajesh Sethuraman; Sameer Chauhan; Piyush Javiya; Shreya Srivastava; Rutvik Patel; Bhagyashri Bhalani
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

4.  A Pilot Study with Randomised Controlled Design Comparing TiZr Alloy Dental Implants to Ti Implants.

Authors:  Kristina Hultin; Annelie Eriksson; Christina Backe; Ulf Johansson; Kostas Bougas
Journal:  J Oral Maxillofac Res       Date:  2020-12-31

Review 5.  Endosseous Dental Implant Materials and Clinical Outcomes of Different Alloys: A Systematic Review.

Authors:  Luca Fiorillo; Marco Cicciù; Tolga Fikret Tozum; Matteo Saccucci; Cristiano Orlando; Giovanni Luca Romano; Cesare D'Amico; Gabriele Cervino
Journal:  Materials (Basel)       Date:  2022-03-07       Impact factor: 3.623

6.  Narrow diameter implants to replace congenital missing maxillary lateral incisors: A 1-year prospective, controlled, clinical study.

Authors:  Andrea Roccuzzo; Jean-Claude Imber; Jakob Lempert; Mandana Hosseini; Simon Storgård Jensen
Journal:  Clin Oral Implants Res       Date:  2022-07-11       Impact factor: 5.021

7.  Bone loss around narrow implants versus standard diameter implants: Retrospective 2-years case-control study.

Authors:  José-Ramón Corcuera-Flores; Manuel Pérez-Fierro; Andrés Blanco-Carrión; Daniel Torres-Lagares; Lizett Castellanos-Cosano; Guillermo Machuca-Portillo
Journal:  J Clin Exp Dent       Date:  2020-01-01

8.  Longevity and marginal bone loss of narrow-diameter implants supporting single crowns: A systematic review.

Authors:  Lucas Henrique Telles; Fernando Freitas Portella; Elken Gomes Rivaldo
Journal:  PLoS One       Date:  2019-11-11       Impact factor: 3.240

9.  Implant-prosthetic rehabilitation of patients with severe horizontal bone deficit on mini-implants with two-piece design-retrospective analysis after a mean follow-up of 5 years.

Authors:  Lukas Wimmer; Pantelis Petrakakis; Karim El-Mahdy; Surian Herrmann; Dirk Nolte
Journal:  Int J Implant Dent       Date:  2021-07-28
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.