Literature DB >> 26929953

Clinical and Radiographic Evaluation of a Small-Diameter Dental Implant Used for the Restoration of Patients with Permanent Tooth Agenesis (Hypodontia) in the Maxillary Lateral Incisor and Mandibular Incisor Regions: A 36-Month Follow-Up.

Paul King, Carlo Maiorana, Ralph G Luthardt, Katarina Sondell, Jesper Øland, Pablo Galindo-Moreno, Peter Nilsson.   

Abstract

PURPOSE: For patients with narrow, single-tooth edentulous ridges as a result of permanent tooth agenesis (hypodontia) in the maxillary lateral and mandibular incisor regions, dental implant treatment may present a reliable and predictable restorative treatment solution. The aim of the present study was to evaluate the clinical reliability and outcome of small-diameter dental implants placed in a one-stage procedure with early loading replacing maxillary lateral or mandibular incisor teeth.
MATERIALS AND METHODS: Patients with hypodontia in the maxillary lateral incisor or mandibular incisor region analyzed in this report were selected from a larger prospective multicenter study. Small-diameter dental implants (AstraTech OsseoSpeed TX 3.0 S, Dentsply) of different lengths were placed using a one-stage surgical protocol with a 6- to 10-week healing period before loading. Probing pocket depth, bleeding on probing, and gingival zenith score were assessed after 6, 12, 24, and 36 months. Radiographic examination was assessed at 6, 12, and 36 months.
RESULTS: In total, 38 patients were included in this analysis and 62 small-diameter implants were placed. The mean distance between adjacent teeth was 6.30 mm (SD: 1.36). All patients received a titanium transmucosal abutment and cement-retained ceramic crown after 6 to 10 weeks of healing. Two implants were lost during the healing period before loading, providing a total implant survival rate of 96.8%. No implant fractures were reported. Mean marginal bone level change from surgery to follow-up visits at 6, 12, and 36 months were 0.39 mm, 0.22 mm, and 0.23 mm, respectively. The condition of soft tissue was stable at all follow-up visits with clinically insignificant changes in probing depth, bleeding on probing, and gingival zenith score.
CONCLUSION: This study evaluated the behavior over 36 months of AstraTech Osseospeed TX 3.0 S dental implants placed into narrow one-tooth defect edentulous ridges as a result of hypodontia. The data collected highlighted the stability of the marginal bone level and soft tissues around the dental implants in conjunction with durable mechanical function. Small-diameter implants can be considered a valid solution in the restorative treatment of hypodontia in the maxillary lateral and mandibular incisor regions.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26929953     DOI: 10.11607/ijp.4444

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  4 in total

1.  Root Dimensions in Patients with Mild Hypodontia and a Control Group.

Authors:  Khaled Khalaf; Zahra Seraj; Hesham Hussein; Mahmoud Mando
Journal:  Eur J Dent       Date:  2019-12-31

2.  Influence of risk factors on the long-term survival of oral rehabilitation with extra-narrow implants: a retrospective study.

Authors:  Elcio Marcantonio Junior; Ivete Aparecida de Mattias Sartori; Camila Pereira Vianna; Roberta Schroder Rocha; Waleska Caldas; Larissa Carvalho Trojan
Journal:  J Appl Oral Sci       Date:  2022-08-01       Impact factor: 3.144

3.  Narrow diameter implants to replace congenital missing maxillary lateral incisors: A 1-year prospective, controlled, clinical study.

Authors:  Andrea Roccuzzo; Jean-Claude Imber; Jakob Lempert; Mandana Hosseini; Simon Storgård Jensen
Journal:  Clin Oral Implants Res       Date:  2022-07-11       Impact factor: 5.021

4.  Longevity and marginal bone loss of narrow-diameter implants supporting single crowns: A systematic review.

Authors:  Lucas Henrique Telles; Fernando Freitas Portella; Elken Gomes Rivaldo
Journal:  PLoS One       Date:  2019-11-11       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.