Literature DB >> 11324210

A prospective clinical study evaluating the safety and effectiveness of narrow-diameter threaded implants in the anterior region of the maxilla.

E Andersen1, E Saxegaard, B M Knutsen, H R Haanaes.   

Abstract

The aim of the present study of single-tooth implants was to compare the success rate and marginal bone resorption of a narrow-diameter self-tapping implant placed in less available bone volume with the standard-diameter self-tapping implant placed in a well-dimensioned alveolar process. A new abutment technique and a different permanent abutment design were also evaluated. Fifty-five patients were included in the study; 27 patients received 28 standard-diameter (3.75-mm) implants, and 28 patients received 32 narrow-diameter (3.25-mm) implants replacing either a central or a lateral incisor in the maxilla. In an attempt to create an ideal emergence profile and to regenerate papillae, individual acrylic resin tooth-shaped temporary abutments were fabricated, based on impressions made immediately following implant placement, and connected to the implant after 6 months. A minimum of 2 months were then allowed before definitive restorative procedures were performed. Impressions were always made at the implant level. Follow-up examinations were performed at 6 months after loading and 1, 2, and 3 years after loading. Two narrow-diameter implants were lost after 6 months, but no other failures were subsequently observed in any of the groups after that. In both groups, marginal bone loss followed the same pattern and was recorded radiographically to be a mean of 0.4 mm from the first to the last examination.

Entities:  

Mesh:

Year:  2001        PMID: 11324210

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  12 in total

1.  Biomechanical effects of the implant material and implant-abutment interface in immediately loaded small-diameter implants.

Authors:  Aaron Yu-Jen Wu; Heng-Li Huang; Jui-Ting Hsu; Winston Chee
Journal:  Clin Oral Investig       Date:  2013-09-03       Impact factor: 3.573

2.  Long-term implant success at the Academy for Oral Implantology: 8-year follow-up and risk factor analysis.

Authors:  Dieter Busenlechner; Rudolf Fürhauser; Robert Haas; Georg Watzek; Georg Mailath; Bernhard Pommer
Journal:  J Periodontal Implant Sci       Date:  2014-06-05       Impact factor: 2.614

3.  Two versus three narrow-diameter implants with locator attachments supporting mandibular overdentures: a two-year prospective study.

Authors:  Ali M El-Sheikh; Omar F Shihabuddin; Sahar M F Ghoraba
Journal:  Int J Dent       Date:  2012-06-18

4.  Clinical evaluation of small diameter straumann implants in partially edentulous patients: a 5-year retrospective study.

Authors:  M Yaltirik; B Gökçen-Röhlig; S Ozer; G Evlioglu
Journal:  J Dent (Tehran)       Date:  2011-06-30

Review 5.  Retention failures in cement- and screw-retained fixed restorations on dental implants in partially edentulous arches: A systematic review with meta-analysis.

Authors:  Jatin K Jain; Rajesh Sethuraman; Sameer Chauhan; Piyush Javiya; Shreya Srivastava; Rutvik Patel; Bhagyashri Bhalani
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

6.  Influence of length, diameter and position of the implant in its fracture incidence: A Systematic Review.

Authors:  Marcelo Coelho Goiato; Agda Marobo Andreotti; Daniela Micheline Dos Santos; Adhara Smith Nobrega; Fernanda Pereira de Caxias; Lisiane Cristina Bannwart
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2019-08-14

7.  Use of Narrow-Diameter Implants in Completely Edentulous Patients as a Prosthetic Option: A Systematic Review of the Literature.

Authors:  S Storelli; A Caputo; G Palandrani; M Peditto; M Del Fabbro; E Romeo; G Oteri
Journal:  Biomed Res Int       Date:  2021-06-22       Impact factor: 3.411

8.  Narrow diameter implant in posterior region.

Authors:  Jumshad B Mohamed; Md Nazish Alam; Arif Salman; S C Chandrasekaran
Journal:  J Indian Soc Periodontol       Date:  2012-10

9.  Failure Modes and Survival of Anterior Crowns Supported by Narrow Implant Systems.

Authors:  Edmara T P Bergamo; Everardo N S de Araújo-Júnior; Adolfo C O Lopes; Paulo G Coelho; Abbas Zahoui; Ernesto B Benalcázar Jalkh; Estevam A Bonfante
Journal:  Biomed Res Int       Date:  2020-09-07       Impact factor: 3.411

10.  Longevity and marginal bone loss of narrow-diameter implants supporting single crowns: A systematic review.

Authors:  Lucas Henrique Telles; Fernando Freitas Portella; Elken Gomes Rivaldo
Journal:  PLoS One       Date:  2019-11-11       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.