Literature DB >> 28994192

Narrow- and regular-diameter implants in the posterior region of the jaws to support single crowns: A 3-year split-mouth randomized clinical trial.

André Barbisan de Souza1, Flávia Sukekava2, Livia Tolentino3, João Batista César-Neto2, João Garcez-Filho4, Mauricio G Araújo5.   

Abstract

OBJECTIVES: The objective of this 3-year split-mouth randomized controlled clinical study was to compare narrow-diameter implants (NDIs) to regular-diameter implants (RDIs) in the posterior region of the jaws (premolars and molars) in regards to (i) the marginal bone level (MBL) and (ii) implant and prosthesis survival and success rates.
MATERIAL AND METHODS: A total of 22 patients were included in the study. Each patient received at least one implant of each diameter (Ø3.3 and Ø4.1 mm), placed either in the maxilla or mandible to support single crowns. A total 44 implants (22 NDIs and 22 RDIs) were placed and included in the study. Twenty-one implants were placed in the premolar, whereas 23 were placed in molar areas. Radiographic evaluations to access the MBL were performed immediately after implant placement, 1 and 3 years after implant loading. Peri-implant clinical variables including probing pocket depth (PPD) and bleeding on probing (BoP) were obtained after crown delivery, 1 and 3 years after loading. Furthermore, the survival and success rates of the implants and prosthesis were also evaluated.
RESULTS: Twenty patients were able to complete the study. There was no statistically significant difference regarding MBL between groups at implant placement (p = .084), 1-year (p = .794) and 3-year (p = .598) time intervals. The mean peri-implant bone loss at 3-year follow-up was -0.58 ± 0.39 mm (95% CI: -0.751 to -0.409) and -0.53 ± 0.46 mm (95% CI: -0.731 to -0.329) for NDIs and RDIs, respectively. BoP was present at 15% and 10% of NDIs and RDIs, respectively, at 3-year follow-up. PPD >5 mm was observed in 5% and 0% of the implants of NDIs and RDIs, respectively, at 3-year follow-up. At the 3-year examination, the implant success rates were in the NDIs and RDIs sites, respectively, 95% and 100%. The corresponding values for prosthesis success rates were 90% for NDIs and 95% for RDIs.
CONCLUSION: The present study demonstrated that NDIs placed to support single crowns in the posterior region did not differ to RDIs in regards to MBL, implant survival, and success rates.
© 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  bone resorption; dental implants; narrow diameter; radiography

Mesh:

Year:  2017        PMID: 28994192     DOI: 10.1111/clr.13076

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

Review 1.  Horizontal augmentation techniques in the mandible: a systematic review.

Authors:  Ralf Smeets; Levi Matthies; Peter Windisch; Martin Gosau; Ronald Jung; Nadine Brodala; Martina Stefanini; Johannes Kleinheinz; Michael Payer; Anders Henningsen; Bilal Al-Nawas; Christian Knipfer
Journal:  Int J Implant Dent       Date:  2022-05-09

2.  Influence of risk factors on the long-term survival of oral rehabilitation with extra-narrow implants: a retrospective study.

Authors:  Elcio Marcantonio Junior; Ivete Aparecida de Mattias Sartori; Camila Pereira Vianna; Roberta Schroder Rocha; Waleska Caldas; Larissa Carvalho Trojan
Journal:  J Appl Oral Sci       Date:  2022-08-01       Impact factor: 3.144

3.  Longevity and marginal bone loss of narrow-diameter implants supporting single crowns: A systematic review.

Authors:  Lucas Henrique Telles; Fernando Freitas Portella; Elken Gomes Rivaldo
Journal:  PLoS One       Date:  2019-11-11       Impact factor: 3.240

4.  Clinical and radiographic assessment of narrow-diameter and regular-diameter implants in the anterior and posterior jaw: 2 to 6 years of follow-up.

Authors:  Mohammed Alrabiah; Modhi Al Deeb; Abdulaziz Alsahhaf; Yasser F AlFawaz; Khulud Abdulrahman Al-Aali; Fahim Vohra; Tariq Abduljabbar
Journal:  J Periodontal Implant Sci       Date:  2020-01-21       Impact factor: 2.614

5.  Clinical outcome of implants placed in grafted maxillary sinus via lateral approach: A 10-year follow-up study.

Authors:  Jinhee Ha; Jang-Ho Son; Iel-Yong Sung; Yeong-Cheol Cho; Jong-Ho Choi
Journal:  J Dent Sci       Date:  2020-06-03       Impact factor: 2.080

6.  One-year performance of posterior narrow diameter implants in hyperglycemic and normo-glycemic patients-a pilot study.

Authors:  Anton Friedmann; Marianna Winkler; Daniel Diehl; Mehmet Selim Yildiz; Hakan Bilhan
Journal:  Clin Oral Investig       Date:  2021-05-03       Impact factor: 3.573

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.