Investigating the effect of characteristic x-rays in cadmium zinc telluride detectors under breast computerized tomography operating conditions.

Stephen J Glick, Clay Didier.   

Abstract

A number of research groups have been investigating the use of dedicated breast computerized tomography (CT). Preliminary results have been encouraging, suggesting an improved visualization of masses on breast CT as compared to conventional mammography. Nonetheless, there are many challenges to overcome before breast CT can become a routine clinical reality. One potential improvement over current breast CT prototypes would be the use of photon counting detectors with cadmium zinc telluride (CZT) (or CdTe) semiconductor material. These detectors can operate at room temperature and provide high detection efficiency and the capability of multi-energy imaging; however, one factor in particular that limits image quality is the emission of characteristic x-rays. In this study, the degradative effects of characteristic x-rays are examined when using a CZT detector under breast CT operating conditions. Monte Carlo simulation software was used to evaluate the effect of characteristic x-rays and the detector element size on spatial and spectral resolution for a CZT detector used under breast CT operating conditions. In particular, lower kVp spectra and thinner CZT thicknesses were studied than that typically used with CZT based conventional CT detectors. In addition, the effect of characteristic x-rays on the accuracy of material decomposition in spectral CT imaging was explored. It was observed that when imaging with 50-60 kVp spectra, the x-ray transmission through CZT was very low for all detector thicknesses studied (0.5-3.0 mm), thus retaining dose efficiency. As expected, characteristic x-ray escape from the detector element of x-ray interaction increased with decreasing detector element size, approaching a 50% escape fraction for a 100 μm size detector element. The detector point spread function was observed to have only minor degradation with detector element size greater than 200 μm and lower kV settings. Characteristic x-rays produced increasing distortion in the spectral response with decreasing detector element size. If not corrected for, this caused a large bias in estimating tissue density parameters for material decomposition. It was also observed that degradation of the spectral response due to characteristic x-rays caused worsening precision in the estimation of tissue density parameters. It was observed that characteristic x-rays do cause some degradation in the spatial and spectral resolution of thin CZT detectors operating under breast CT conditions. These degradations should be manageable with careful selection of the detector element size. Even with the observed spectral distortion from characteristic x-rays, it is still possible to correctly estimate tissue parameters for material decomposition using spectral CT if accurate modeling is used.

Entities:  

Year:  2013        PMID: 24187383      PMCID: PMC3808444          DOI: 10.1063/1.4821342

Source DB:  PubMed          Journal:  J Appl Phys        ISSN: 0021-8979            Impact factor:   2.546


  33 in total

1.  Cone-beam CT for breast imaging: Radiation dose, breast coverage, and image quality.

Authors:  Avice O'Connell; David L Conover; Yan Zhang; Posy Seifert; Wende Logan-Young; Chuen-Fu Linda Lin; Lawrence Sahler; Ruola Ning
Journal:  AJR Am J Roentgenol       Date:  2010-08       Impact factor: 3.959

2.  CT energy weighting in the presence of scatter and limited energy resolution.

Authors:  Taly Gilat Schmidt
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

3.  Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study.

Authors:  Hans Bornefalk; Mats Danielsson
Journal:  Phys Med Biol       Date:  2010-03-19       Impact factor: 3.609

4.  Photon counting computed tomography: concept and initial results.

Authors:  Polad M Shikhaliev; Tong Xu; Sabee Molloi
Journal:  Med Phys       Date:  2005-02       Impact factor: 4.071

5.  K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors.

Authors:  E Roessl; R Proksa
Journal:  Phys Med Biol       Date:  2007-07-17       Impact factor: 3.609

6.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

Authors:  J P Schlomka; E Roessl; R Dorscheid; S Dill; G Martens; T Istel; C Bäumer; C Herrmann; R Steadman; G Zeitler; A Livne; R Proksa
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

7.  Spectral optimization for dedicated breast CT.

Authors:  Michaela Weigel; Sabrina V Vollmar; Willi A Kalender
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

8.  Monte Carlo investigation of charge-transport effects on energy resolution and detection efficiency of pixelated CZT detectors for SPECT/PET applications.

Authors:  Marios E Myronakis; Dimitra G Darambara
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

9.  Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application.

Authors:  Polad M Shikhaliev; Shannon G Fritz
Journal:  Phys Med Biol       Date:  2011-03-02       Impact factor: 3.609

10.  Modeling the performance of a photon counting x-ray detector for CT: energy response and pulse pileup effects.

Authors:  Katsuyuki Taguchi; Mengxi Zhang; Eric C Frey; Xiaolan Wang; Jan S Iwanczyk; Einar Nygard; Neal E Hartsough; Benjamin M W Tsui; William C Barber
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

View more
  2 in total

1.  Resolution characterization of a silicon-based, photon-counting computed tomography prototype capable of patient scanning.

Authors:  Joakim da Silva; Fredrik Grönberg; Björn Cederström; Mats Persson; Martin Sjölin; Zlatan Alagic; Robert Bujila; Mats Danielsson
Journal:  J Med Imaging (Bellingham)       Date:  2019-10-15

2.  Characterization of energy response for photon-counting detectors using x-ray fluorescence.

Authors:  Huanjun Ding; Hyo-Min Cho; William C Barber; Jan S Iwanczyk; Sabee Molloi
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071