Literature DB >> 30191571

A framework for performance characterization of energy-resolving photon-counting detectors.

Mats Persson1, Paurakh L Rajbhandary2, Norbert J Pelc3.   

Abstract

PURPOSE: Photon-counting, energy-resolving detectors are subject to intense research interest, and there is a need for a general framework for performance assessment of these detectors. The commonly used linear-systems theory framework, which measures detector performance in terms of noise-equivalent quanta (NEQ) and detective quantum efficiency (DQE) is widely used for characterizing conventional x-ray detectors but does not take energy-resolving capabilities into account. The purpose of this work is to extend this framework to encompass energy-resolving photon-counting detectors and elucidate how the imperfect energy response and other imperfections in real-world detectors affect imaging performance, both for feature detection and for material quantification tasks.
METHOD: We generalize NEQ and DQE to matrix-valued quantities as functions of spatial frequency, and show how these matrices can be calculated from simple Monte Carlo simulations. To demonstrate how the new metrics can be interpreted, we compute them for simplified models of fluorescence and Compton scatter in a photon-counting detector and for a Monte Carlo model of a CdTe detector with 0.5 × 0.5 mm 2 pixels.
RESULTS: Our results show that the ideal-linear-observer performance for any detection or material quantification task can be calculated from the proposed generalized NEQ and DQE metrics. We also demonstrate that the proposed NEQ metric is closely related to a generalized version of the Cramér-Rao lower bound commonly used for assessing material quantification performance. Off-diagonal elements in the NEQ and DQE matrices are shown to be related to loss of energy information due to imperfect energy resolution. The Monte Carlo model of the CdTe detector predicts a zero-frequency dose efficiency relative to an ideal detector of 0.86 and 0.65 for detecting water and bone, respectively. When the task instead is to quantify these materials, the corresponding values are 0.34 for water and 0.26 for bone.
CONCLUSIONS: We have developed a framework for assessing the performance of photon-counting energy-resolving detectors and shown that the matrix-valued NEQ and DQE metrics contain sufficient information for calculating the dose efficiency for both detection and quantification tasks, the task having any spatial and energy dependence. This framework will be beneficial for the development and optimization of photon-counting x-ray detectors.
© 2018 American Association of Physicists in Medicine.

Entities:  

Keywords:  Cramér-Rao lower bound; detective quantum efficiency; linear-systems theory; noise-equivalent quanta; photon counting; spectral imaging; x-ray imaging

Mesh:

Year:  2018        PMID: 30191571      PMCID: PMC6234069          DOI: 10.1002/mp.13172

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  37 in total

1.  Detective quantum efficiency dependence on x-ray energy weighting in mammography.

Authors:  R N Cahn; B Cederström; M Danielsson; A Hall; M Lundqvist; D Nygren
Journal:  Med Phys       Date:  1999-12       Impact factor: 4.071

2.  Task-based weights for photon counting spectral x-ray imaging.

Authors:  Hans Bornefalk
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

3.  Photon counting computed tomography: concept and initial results.

Authors:  Polad M Shikhaliev; Tong Xu; Sabee Molloi
Journal:  Med Phys       Date:  2005-02       Impact factor: 4.071

4.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

Authors:  J P Schlomka; E Roessl; R Dorscheid; S Dill; G Martens; T Istel; C Bäumer; C Herrmann; R Steadman; G Zeitler; A Livne; R Proksa
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

5.  Size-dependent scanning parameters (kVp and mAs) for photon-counting spectral CT system in pediatric imaging: simulation study.

Authors:  Han Chen; Mats Danielsson; Cheng Xu
Journal:  Phys Med Biol       Date:  2016-05-10       Impact factor: 3.609

6.  Near optimal energy selective x-ray imaging system performance with simple detectors.

Authors:  Robert E Alvarez
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

7.  Detective quantum efficiency of photon-counting x-ray detectors.

Authors:  Jesse Tanguay; Seungman Yun; Ho Kyung Kim; Ian A Cunningham
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

8.  An efficient computational approach to model statistical correlations in photon counting x-ray detectors.

Authors:  Sebastian Faby; Joscha Maier; Stefan Sawall; David Simons; Heinz-Peter Schlemmer; Michael Lell; Marc Kachelrieß
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

9.  Generalized image combinations in dual KVP digital radiography.

Authors:  L A Lehmann; R E Alvarez; A Macovski; W R Brody; N J Pelc; S J Riederer; A L Hall
Journal:  Med Phys       Date:  1981 Sep-Oct       Impact factor: 4.071

10.  Energy-resolved CT imaging with a photon-counting silicon-strip detector.

Authors:  Mats Persson; Ben Huber; Staffan Karlsson; Xuejin Liu; Han Chen; Cheng Xu; Moa Yveborg; Hans Bornefalk; Mats Danielsson
Journal:  Phys Med Biol       Date:  2014-10-20       Impact factor: 3.609

View more
  5 in total

1.  Detective quantum efficiency of photon-counting CdTe and Si detectors for computed tomography: a simulation study.

Authors:  Mats Persson; Adam Wang; Norbert J Pelc
Journal:  J Med Imaging (Bellingham)       Date:  2020-07-17

2.  Resolution characterization of a silicon-based, photon-counting computed tomography prototype capable of patient scanning.

Authors:  Joakim da Silva; Fredrik Grönberg; Björn Cederström; Mats Persson; Martin Sjölin; Zlatan Alagic; Robert Bujila; Mats Danielsson
Journal:  J Med Imaging (Bellingham)       Date:  2019-10-15

3.  The markerless lung target tracking AAPM Grand Challenge (MATCH) results.

Authors:  Marco Mueller; Per Poulsen; Rune Hansen; Wilko Verbakel; Ross Berbeco; Dianne Ferguson; Shinichiro Mori; Lei Ren; John C Roeske; Lei Wang; Pengpeng Zhang; Paul Keall
Journal:  Med Phys       Date:  2021-12-29       Impact factor: 4.071

4.  Spectral Photon Counting CT: Imaging Algorithms and Performance Assessment.

Authors:  Adam S Wang; Norbert J Pelc
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-07-07

5.  Frequency-dependent signal and noise in spectroscopic x-ray imaging.

Authors:  Jesse Tanguay; Jinwoo Kim; Ho Kyung Kim; Kris Iniewski; Ian A Cunningham
Journal:  Med Phys       Date:  2020-04-22       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.