| Literature DB >> 31546479 |
Varun Saini1, Usha K Raina1, Anika Gupta1, Jawahar Lal Goyal1, Raffat Anjum1, Pallavi Saini2, Shantanu Kumar Gupta1, Prateeksha Sharma1.
Abstract
Purpose: To compare refractive measurements of noncycloplegic photoscreener Plusoptix S12R with cycloplegic retinoscopy, noncycloplegic autorefractor, and cycloplegic autorefractor in children.Entities:
Keywords: Amblyopia; photoscreener; refractive errors
Mesh:
Substances:
Year: 2019 PMID: 31546479 PMCID: PMC6786145 DOI: 10.4103/ijo.IJO_1465_18
Source DB: PubMed Journal: Indian J Ophthalmol ISSN: 0301-4738 Impact factor: 1.848
Figure 1Comparison between mean sphere (S), spherical equivalent (SE), and cylinder (C) values of cycloplegic retinoscopy (CR) and Plusoptix in Group 1
Comparison between cycloplegic retinoscopy and Plusoptix in Group 1
| Cycloplegic retinoscopy vs Plusoptix | |||
|---|---|---|---|
| Mean±SD | 95% CI | ||
| DS (D) | 0.68±0.55 | <0.001 | 0.58-0.79 |
| DSE (D) | 0.77±0.61 | <0.001 | 0.65-0.89 |
| DC (D) | 0.18±0.28 | <0.001 | 0.12-0.24 |
SD=Standard deviation; CI=Confidence interval; DS=Difference in sphere, DSE=Difference in spherical equivalent, DC=Difference in cylinder, D=Diopter. *Paired t-test significant at P<0.05
Figure 2Comparison between mean sphere (S), spherical equivalent (SE), and cylinder (C) values of cycloplegic retinoscopy (CR), Plusoptix, cycloplefic autorefraction (CAR), and noncycloplefic autorefraction (NCAR) in Group 2
Comparison between cycloplegic retinoscopy, Plusoptix, CAR, and NCAR in Group 2
| Cycloplegic retinoscopy vs. Plusoptix | CAR vs. Plusoptix | NCAR vs. Plusoptix | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Mean±SD | 95% CI | Mean±SD | 95% CI | Mean±SD | 95% CI | ||||
| DS (D) | 0.86±0.49 | <0.001 | 0.76-0.95 | 0.69±0.47 | <0.001 | 0.59-0.78 | -0.25±0.39 | <0.001 | -0.32--0.17 |
| DSE (D) | 0.97±0.51 | <0.001 | 0.87-1.07 | 0.74±0.49 | <0.001 | 0.64-0.84 | -0.19±0.41 | <0.001 | -0.27--0.11 |
| DC (D) | 0.23±0.28 | <0.001 | 0.17-0.28 | 0.10±0.31 | 0.002 | 0.03-0.16 | 0.11±0.31 | <0.001 | 0.05-0.17 |
CAR=Cycloplegic autorefraction, NCAR=Noncycloplegic autorefraction, CI=Confidence interval, DS=Difference in sphere, DSE=Difference in spherical equivalent, DC=Difference in cylinder, D=Diopter. *Paired t-test significant at P<0.05
Figure 3Bland–Altman plots for S (sphere), SE (spherical equivalent), and C (cylinder) measurements by cycloplegic retinoscopy versus Plusoptix in Group 1
Figure 4Bland–Altman plots for S (sphere), SE (spherical equivalent), and C (cylinder) measurements by cycloplegic retinoscopy versus Plusoptix in Group 2