Literature DB >> 23679982

A comparison of the Plusoptix S08 photorefractor to retinoscopy and cycloretinoscopy.

Ali Mirzajani1, Mohsen Heirani, Ebrahim Jafarzadehpur, Hamid Haghani.   

Abstract

BACKGROUND: The aim was to compare outcome measures of refractive error by the Plusoptix S08 photorefractor with measures obtained by retinoscopy and cycloretinoscopy in children.
METHOD: The refractive error of the right eye of 144 non-strabismic children, aged 2.5 to 5.5 years, was determined by Plusoptix S08 photorefraction, retinoscopy and cycloretinoscopy. Agreement between outcome measures of refractive error (spherical error, cylindrical error and spherical equivalent) by the three techniques were tested by Bland-Altman limits of agreement.
RESULTS: The mean difference for spherical equivalent results of photorefraction (P(se)) minus those of retinoscopy (R(se)) and photorefraction minus those of cycloretinoscopy (CR(se)) were +0.53 ± 0.62 D and -0.22 ± 0.75 D, respectively. The 95 per cent limits of agreement for spherical photorefraction with retinoscopy and cycloretinoscopy were ±1.22 D (range -0.69 to +1.75) and ±1.47 D (range -1.69 to +1.25), respectively. The mean difference for cylindrical results of photorefraction (P(c)) minus those of retinoscopy (R(c)) and Pc minus those of cycloretinoscopy (CR(c)) were +0.11 ± 0.39 D and +0.13 ± 0.44 D, respectively. The 95 per cent limits of agreement for P(c) with R(c) and CR(c) were ±0.76 D (range -0.65 to +0.87) and ±0.86 D (range -0.73 to +0.99), respectively. The mean and standard deviation of weighted axes difference, comparing Plusoptix S08 and retinoscopy was 0.25 ± 0.36 and comparing Plusoptix S08 and cycloretinoscopy was 0.29 ± 0.51. Eighty-two per cent of the spherical equivalent findings in photorefraction and cycloretinoscopy show a difference of within 1.00 D. Regarding cylindrical power, this percentage is 96.6 per cent.
CONCLUSION: As the findings demonstrate a fairly good consistency between the results of the Plusoptix S08 Photorefractor without using cycloplegic agents and those of cycloretinoscopy, the Plusoptix S08 is a fairly accurate tool to estimate refractive errors of children in the limited working range of the instrument.
© 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

Entities:  

Keywords:  Plusoptix S08; cycloretinoscopy; photorefraction; retinoscopy

Mesh:

Year:  2013        PMID: 23679982     DOI: 10.1111/cxo.12063

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  8 in total

1.  Performance of Photoscreener in Detection of Refractive Error in All Age Groups and Amblyopia Risk Factors in Children in a Tribal District of Odisha: The Tribal Odisha Eye Disease Study (TOES) # 3.

Authors:  Lapam Panda; Umasankar Barik; Suryasmita Nayak; Biswajit Barik; Gyanaranjan Behera; Ramesh Kekunnaya; Taraprasad Das
Journal:  Transl Vis Sci Technol       Date:  2018-06-04       Impact factor: 3.283

2.  Convergence and Accommodation Development Is Preprogrammed in Premature Infants.

Authors:  Anna M Horwood; Sonia S Toor; Patricia M Riddell
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-08       Impact factor: 4.799

3.  Performance of the Plusoptix A09 photoscreener in detecting amblyopia risk factors in Chinese children attending an eye clinic.

Authors:  Xiao-Ran Yan; Wan-Zhen Jiao; Zhi-Wei Li; Wen-Wen Xu; Feng-Jiao Li; Li-Hua Wang
Journal:  PLoS One       Date:  2015-06-01       Impact factor: 3.240

4.  Vision screening for children 36 to <72 months: recommended practices.

Authors:  Susan A Cotter; Lynn A Cyert; Joseph M Miller; Graham E Quinn
Journal:  Optom Vis Sci       Date:  2015-01       Impact factor: 1.973

5.  Accuracy of PlusOptix A09 distance refraction in pediatric myopia and hyperopia.

Authors:  Arnaud Payerols; Claudie Eliaou; Véronique Trezeguet; Max Villain; Vincent Daien
Journal:  BMC Ophthalmol       Date:  2016-06-01       Impact factor: 2.209

6.  Tribal Odisha Eye Disease Study # 4: Accuracy and utility of photorefraction for refractive error correction in tribal Odisha (India) school screening.

Authors:  Sandeep Reddy; Lapam Panda; Anjul Kumar; Suryasmita Nayak; Taraprasad Das
Journal:  Indian J Ophthalmol       Date:  2018-07       Impact factor: 1.848

7.  Introducing a new method of retinoscopy for refraction of infants and young children: The "Mirza" tele lens retinoscopy.

Authors:  Ali Mirzajani; Rasoul Amini Vishteh; Masoumeh Khalilian
Journal:  J Optom       Date:  2020-09-22

8.  Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group.

Authors:  Varun Saini; Usha K Raina; Anika Gupta; Jawahar Lal Goyal; Raffat Anjum; Pallavi Saini; Shantanu Kumar Gupta; Prateeksha Sharma
Journal:  Indian J Ophthalmol       Date:  2019-10       Impact factor: 1.848

  8 in total