| Literature DB >> 31516867 |
Kalamalla A SaranBabu1, Dinesh Kumar Perisetty2, Gunaranjan Thota3, Mahammad Rasool4, Mungara Niharika2, Sannapureddy Swapna2.
Abstract
OBJECTIVES: To test the hypothesis that radius of curvature at gingival embrasure in connector area significantly affects the fracture resistance of full-contour monolithic zirconia three-unit posterior Fixed partial denture (FPD) on various amounts of load application.Entities:
Keywords: Finite element analysis; full-contour monolithic zirconia FPD; gingival embrasure radii
Year: 2019 PMID: 31516867 PMCID: PMC6714414 DOI: 10.4103/jispcd.JISPCD_20_19
Source DB: PubMed Journal: J Int Soc Prev Community Dent ISSN: 2231-0762
Figure 1Schematic illustration of connector design
Figure 2Grouping different parameters involved in the study
Figure 3Modeling of D2 density bone
Figure 7Modeling of three-unit FPD connector designs
Figure 8Mesh structure of three-unit FPD
Figure 9Application of load
Figure 10Finite element analysis
Stress concentration for lava zirconia in both connector designs- Stastical analysis
| Load (N) | Design I (MPa) | Design II (MPa) |
|---|---|---|
| 400 | 545.634 | 882.543 |
| 600 | 818.451 | 1323.81 |
| 800 | 1091.27 | 1765.09 |
| Mean ± SD | 818.452 ± 272.82 | 1323.81 ± 441.27 |
| 0.035 (Sig.) | ||
connector designs - Stastical analysis
Stress distribution for cercon zirconia in both connector designs- Stastical analysis
| Load (N) | Design I (MPa) | Design II (MPa) |
|---|---|---|
| 400 | 0.01 | 0.019 |
| 600 | 0.02 | 0.02 |
| 800 | 0.03 | 0.03 |
| Mean ± SD | 0.02 ± 0.01 | 0.023 ± 0.006 |
| 0.423 (Not significant) | ||
Graph 1Stress concentration graph after loading in premolar-molar connector
Graph 2Stress concentration graph after loading in molar-molar connector
Graph 3Statistical analysis
| Material | Elastic modulus | Poisson’s ratio |
|---|---|---|
| Dentin | 18,600 MPa | 0.31 |
| Periodontal ligament | 50 MPa | 0.49 |
| Cortical bone | 345 MPa | 0.3 |
| Cancellous bone | 13,800 MPa | 0.26 |
| Lava | 205 GPa | 0.19 |
| Cercon | 210 GPa | 0.3 |
Stress concentration for cercon zirconia in both connector designs- Stastical analysis
| Load (N) | Design I (MPa) | Design II (MPa) |
|---|---|---|
| 400 | 556.363 | 1027.2 |
| 600 | 834.545 | 1369.6 |
| 800 | 1112.78 | 1826.2 |
| Mean ± SD | 834.56 ± 278.21 | 1407.67 ± 400.86 |
| 0.016 (Sig.) | ||
connector designs- Stastical analysis
Stress distribution for lava zirconia in both connector designs- Stastical analysis
| Load (N) | Design I (MPa) | Design II (MPa) |
|---|---|---|
| 400 | 0.01 | 0.019 |
| 600 | 0.02 | 0.02 |
| 800 | 0.03 | 0.03 |
| Mean ± SD | 0.02 ± 0.01 | 0.023 ± 0.006 |
| 0.423 (Not significant) | ||