Literature DB >> 17451508

Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks.

Philipp Kohorst1, Timo J Herzog, Lothar Borchers, Meike Stiesch-Scholz.   

Abstract

The aim of this in vitro study was to compare the load-bearing capacity of posterior four-unit fixed partial dentures (FPDs) produced with two different yttria-stabilized polycrystalline tetragonal zirconia (Y-TZP) ceramics, one being a presintered material, the other a fully sintered, hot isostatically pressed material. Additionally, as a novel approach, the influence of preliminary mechanical damage upon the fracture force of an FPD has been investigated. A total of 20 frameworks each were milled from presintered zirconia and from fully sintered zirconia. Prior to veneering, 10 frameworks of each material were 'damaged' by a defined saw cut similar to an accidental flaw generated during shape cutting. Before fracture testing, all FPDs were subjected to thermal and mechanical cycling. Additionally, scanning electron microscopy was used to investigate fracture surfaces. Statistical analysis showed that FPDs milled from fully sintered zirconia had a significantly higher fracture resistance compared with specimens made from presintered material, whereas preliminary damage did not have a significant effect. After aging, FPDs made from both materials were capable of withstanding occlusal forces reported in the literature. Therefore, both types of Y-TZP may be suitable for posterior four-unit all-ceramic FPDs, although further prolonged aging experiments and prospective clinical trials are required to prove their fitness for clinical use.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17451508     DOI: 10.1111/j.1600-0722.2007.00429.x

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  14 in total

1.  Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

Authors:  Philipp Kohorst; Janet Junghanns; Marc P Dittmer; Lothar Borchers; Meike Stiesch
Journal:  Clin Oral Investig       Date:  2010-05-22       Impact factor: 3.573

2.  Load-bearing capacity of artificially aged zirconia fixed dental prostheses with heterogeneous abutment supports.

Authors:  Katia Sarafidou; Meike Stiesch; Marc Philipp Dittmer; Daniela Jörn; Lothar Borchers; Philipp Kohorst
Journal:  Clin Oral Investig       Date:  2011-05-24       Impact factor: 3.573

3.  Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials.

Authors:  Joana Schönberger; Kurt-Jürgen Erdelt; Daniel Bäumer; Florian Beuer
Journal:  Clin Oral Investig       Date:  2017-02-04       Impact factor: 3.573

4.  Clinical performance of screw-retained and cemented implant-supported zirconia single crowns: 36-month results.

Authors:  Claudio Cacaci; Friederike Cantner; Thomas Mücke; Peter Randelzhofer; Jan Hajtó; Florian Beuer
Journal:  Clin Oral Investig       Date:  2016-10-29       Impact factor: 3.573

5.  Strength of zirconia fixed partial dentures: review of the literature.

Authors:  M Gargari; F Gloria; A Cappello; L Ottria
Journal:  Oral Implantol (Rome)       Date:  2011-01-23

6.  Fracture resistance of three-unit zirconia fixed partial denture with modified framework.

Authors:  Arthur Partiyan; Essam Osman; Mohammad M Rayyan; Moustafa Aboushelib; Ahmed Ibrahim; Ryo Jimbo
Journal:  Odontology       Date:  2016-04-15       Impact factor: 2.634

7.  Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs).

Authors:  Florian Beuer; Daniel Edelhoff; Wolfgang Gernet; John A Sorensen
Journal:  Clin Oral Investig       Date:  2009-01-24       Impact factor: 3.573

8.  A 3-year follow-up study of all-ceramic single and multiple crowns performed in a private practice: a prospective case series.

Authors:  Gianluca M Tartaglia; Ernesto Sidoti; Chiarella Sforza
Journal:  Clinics (Sao Paulo)       Date:  2011       Impact factor: 2.365

9.  Flexural strengths of implant-supported zirconia based bridges in posterior regions.

Authors:  Mansour Rismanchian; Soufia Shafiei; Farzaneh Nourbakhshian; Amin Davoudi
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

10.  Effect of framework design on fracture resistance of zirconium oxide posterior fixed partial dentures.

Authors:  Hadi Salimi; Ramin Mosharraf; Omid Savabi
Journal:  Dent Res J (Isfahan)       Date:  2012-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.