| Literature DB >> 31391006 |
Mohamed Samy Abd Elaziz1, Hoda Mohamed Elsobky2, Adel Galal Zaky2, Eslam Ahmed Maher Hassan3, Mahmoud Tawfik KhalafAllah2.
Abstract
BACKGROUND: To evaluate corneal biomechanical properties by the Ocular Response Analyzer (ORA) in non keratoconic patients underwent penetrating keratoplasty (PK).Entities:
Keywords: Corneal biomechanics; Corneal hysteresis; Corneal resistance factor; Ocular response analyzer; Penetrating keratoplasty
Mesh:
Year: 2019 PMID: 31391006 PMCID: PMC6686420 DOI: 10.1186/s12886-019-1186-y
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Distribution of study sample according to Demographic characteristics
| Character | No. | (%) |
|---|---|---|
| Gender | ||
| Male | 14 | 46.7 |
| Female | 16 | 53.3 |
| Age, (years) | ||
| mean ± SD | 33.1 ± 10.13 years | |
| Median (Min, Max) | 30 (20–65) years | |
Comparison between IOP measurements obtained with the ORA and GAT
| IOP measurements (mmHg) | IOP (GAT) ( | IOPcc ( | IOPg ( | Test of significance F |
|
|---|---|---|---|---|---|
| Mean ± SD | 11.80 | 17.27 | 14.64 | 149.04 | <.001* |
| P1 | <.001* | ||||
| P2 | <.001* | ||||
| P3 | <.001* | ||||
F: One Way Repeated Anovea
P: Significance within 3 IOP measurements; p1 Significance between IOP (GAT) and IOPcc, P2: Significance between IOPcc and IOPg, p3: Significance between IOP (GAT) and IOPg
Sig between measurements assessed by Bonferroni Post hoc test
*: statistically significant
IOP (GAT) Intra-ocular pressure (goldmann applanation tonometer)
IOPcc Intra-ocular pressure (cornea compensated)
IOPg Intra-ocular pressure (goldmann related)
Fig. 1Bland-Altman plots representing the difference between IOP cc and IOP GAT versus the mean of both the red dotted lines represent the upper and lower borders of the 95% limits of agreement
Fig. 2Bland-Altman plots representing the difference between IOP g and IOP GAT versus the mean of both, the red dotted lines represent the upper and lower borders of the 95% limits of agreement
Correlations of biometric characteristics (Central graft Thickness, mean keratometric astigmatism, SRE, CH and CRF) with IOP measurements obtained with the ORA and GAT
| Characteristics | Pearson Correlation coefficient (r) | Statistical significance ( |
|---|---|---|
| CH vs. | ||
| IOP GAT | −.413 | .023* |
| IOP cc | −.702 | <.001* |
| IOPg | −.357 | .052 |
| CRF vs. | ||
| IOP GAT | .36 | .051 |
| IOP cc | .05 | .794 |
| IOPg | .446 | .013* |
| SRE vs | ||
| IOP GAT | −.094 | .62 |
| IOP cc | −.168 | .374 |
| IOPg | −.082 | .67 |
| Mean Keratometric Astigmatism vs | ||
| IOP GAT | −.157 | .41 |
| IOP cc | −.220 | .24 |
| IOPg | −.069 | .72 |
| Central graft Thickness vs | ||
| IOP GAT | .249 | .185 |
| IOP cc | .044 | .817 |
| IOPg | .281 | .133 |
*: statistically significant
CH Corneal hysteresis
CRF Corneal resistance factor
SRE Spherical Equivalent Refractive Error
IOP (GAT) Intra-ocular pressure (Goldmann applanation tonometer)
IOPcc Intra-ocular pressure (cornea compensated)
IOPg Intra-ocular pressure (Goldmann related)
Multivariate Regression Analysis Models
| Variable | IOPcc (Adjusted R2 = 0.99) | IOPg (Adjusted R2 = 0.99) | ||
|---|---|---|---|---|
| Standardized Co-efficient (β) | Standardized | |||
| Age | 0.04 | 0.04* | 0.05 | 0.02* |
| Corneal Pathology | 0.002 | 0.9 | −0.004 | 0.9 |
| Central Corneal Thickness | 0.13 | 0.5 | 0.02 | 0.5 |
| Mean astigmatism | −0.003 | 0.9 | 0.003 | 0.9 |
| Mean K | −0.02 | 0.5 | −0.03 | 0.4 |
| CH | −1.3 | < 0.001* | −1.1 | < 0.001* |
| CRF | 0.9 | < 0.001* | 1.2 | < 0.001* |
CH Corneal Hysteresis, CRF Corneal Resistance Factor, IOP cc Corneal Compensated Intraocular Pressure, IOPg Goldman-related IOP, * Statistically significant
Comparing published clinical data of IOP assessment after penetrating keratoplasty
| Study | Indications for keratoplasty (number of eyes) | Duration after PKP | Results (mm hg) | ||
|---|---|---|---|---|---|
| GAT | IOPg | IOPcc | |||
| Fabian ID et al. [ | Different corneal pathologies (51) | 65 months (6 to 209 months) | 14.2 ± 4.4 | 15.1 ± 4.2 | 16.8 ± 4.1 |
| Chou CY et al. [ | Different corneal pathologies (31) | 27.7 months (range 3.0–122.4 months | 17.83 ± 5.8 | N/A | 24.12 ± 8.1 |
| Yenerel et al. [ | Keratoconus (36) | 15 months (range: 15–56 months) | N/A | 14.61 ± 2.72 | 15.46 ± 3.07 |
| Feizi et al. [ | Keratoconus (45) | At least 6 months | 12.2 ± 2.4 | 15.1 ± 3.5 | 15.8 ± 3.3 |
| Our study | Non keratoconus (30) | At least 24 months | 11.80 ± 3.66 | 14.64 ± 4.12 | 17.27 ± 4.61 |
GAT Goldmann applanation tonometer, IOPcc corneal-compensated intraocular pressure, IOPg Goldmann-correlated intraocular pressure, SD standard deviation
NA Not available