Literature DB >> 23607620

Intraocular pressure and corneal biomechanics in Fuchs' endothelial dystrophy and after posterior lamellar keratoplasty.

Kåre Clemmensen1, Jesper Hjortdal.   

Abstract

PURPOSE: To evaluate the precision of techniques for measuring intraocular pressure (IOP) in corneas with presumably altered biomechanical properties.
METHODS: Intraocular pressure was measured with a Goldmann applanation tonometer (GAT), ocular response analyzer (ORA) and dynamic contour tonometer (DCT) in 70 eyes. Thirty-five eyes were normal corneas, 18 eyes had Fuchs' endothelial dystrophy, and 17 eyes had undergone Descemet's stripping automated endothelial keratoplasty (DSAEK) surgery. Corneal hysteresis (CH), corneal resistance factor (CRF) as well as central corneal thickness (CCT) were recorded with the ORA.
RESULTS: The measured cornea-corrected IOP using ORA was significantly higher than GAT in all three groups (p< 0.001). The DCT differed significantly from the Goldmann only in the Fuchs' group (p= 0.04). The Goldmann and DCT showed no significant between-group differences, whereas IOP measured with the ORA was different between groups (p< 0.001). CH in the DSEAK group differed significantly from the controls (p< 0.001), but there was no significant difference between the DSEAK and Fuchs' groups (p= 0.21). CCT did not differ significantly between the DSAEK and Fuchs' group (p= 0.47). However, both these groups differed significantly from the controls (p< 0.001).
CONCLUSION: Corneal hysteresis and CRF are reduced in Fuchs' endothelial dystrophy as well as after posterior lamellar keratoplasty. GAT and DCT seem to measure IOP correctly in patients with Fuchs' endothelial dystrophy as well as after posterior lamellar keratoplasty. Corneal-corrected IOP as measured with the ORA appears to overestimate IOP in patients with Fuchs' endothelial dystrophy as well as after posterior lamellar keratoplasty.
© 2013 Acta Ophthalmologica Scandinavica Foundation. Published by Blackwell Publishing Ltd.

Entities:  

Keywords:  Descemet’s stripping automated endothelial keratoplasty; Fuchs’ endothelial dystrophy; biomechanics; intraocular pressure; tonometry

Mesh:

Year:  2013        PMID: 23607620     DOI: 10.1111/aos.12137

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  11 in total

1.  Does corneal hysteresis correlate with endothelial cell density?

Authors:  Berna Akova-Budak; Sertaç Argun Kıvanç
Journal:  Med Sci Monit       Date:  2015-05-21

2.  Corneal biomechanics and intraocular pressure assessment after penetrating keratoplasty for non keratoconic patients, long term results.

Authors:  Mohamed Samy Abd Elaziz; Hoda Mohamed Elsobky; Adel Galal Zaky; Eslam Ahmed Maher Hassan; Mahmoud Tawfik KhalafAllah
Journal:  BMC Ophthalmol       Date:  2019-08-07       Impact factor: 2.209

3.  Age-related variation in corneal biomechanical parameters in healthy Indians.

Authors:  Vaishal P Kenia; Raj V Kenia; Onkar H Pirdankar
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

4.  Fine-mapping and cell-specific enrichment at corneal resistance factor loci prioritize candidate causal regulatory variants.

Authors:  Xinyi Jiang; Nefeli Dellepiane; Erola Pairo-Castineira; Thibaud Boutin; Yatendra Kumar; Wendy A Bickmore; Veronique Vitart
Journal:  Commun Biol       Date:  2020-12-11

Review 5.  Corneal Biomechanical Assessment with Ultra-High-Speed Scheimpflug Imaging During Non-Contact Tonometry: A Prospective Review.

Authors:  Pedro Manuel Baptista; Renato Ambrosio; Luis Oliveira; Pedro Meneres; Joao Melo Beirao
Journal:  Clin Ophthalmol       Date:  2021-04-06

Review 6.  Challenges in the complex management of post-keratoplasty glaucoma.

Authors:  Lisa-Marie Anders; Zisis Gatzioufas; Matthias C Grieshaber
Journal:  Ther Adv Ophthalmol       Date:  2021-07-20

Review 7.  Corneal biomechanical properties in different ocular conditions and new measurement techniques.

Authors:  Nery Garcia-Porta; Paulo Fernandes; Antonio Queiros; Jose Salgado-Borges; Manuel Parafita-Mato; Jose Manuel González-Méijome
Journal:  ISRN Ophthalmol       Date:  2014-03-04

8.  Relationship between the biomechanical properties of the cornea and anterior segment measurements.

Authors:  Murilo Barreto Souza; Fabricio Witzel de Medeiros; Flavio Fernandes Villela; Milton Ruiz Alves
Journal:  Clinics (Sao Paulo)       Date:  2018-09-21       Impact factor: 2.365

9.  Association of 24-Hour Intraocular Pressure Fluctuation With Corneal Hysteresis and Axial Length in Untreated Chinese Primary Open-Angle Glaucoma Patients.

Authors:  Yaping Yang; Tsz Kin Ng; Li Wang; Na Wu; Ming Xiao; Xinghuai Sun; Yuhong Chen
Journal:  Transl Vis Sci Technol       Date:  2020-11-19       Impact factor: 3.283

10.  Incidence and Risk Factors of Ocular Hypertension/Glaucoma After Descemet Stripping Automated Endothelial Keratoplasty.

Authors:  Mohamed Elalfy; Sundas Maqsood; Shady Soliman; Sherif Momtaz Hegazy; Ahmed Abdou Hannon; Zisis Gatzioufas; Damian Lake; Samer Hamada
Journal:  Clin Ophthalmol       Date:  2021-05-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.