Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes.

Dolores Ortiz1, David Piñero, Mohamed H Shabayek, Francisco Arnalich-Montiel, Jorge L Alió.   

Abstract

PURPOSE: To compare the biomechanical properties of normal, post-laser in situ keratomileusis (LASIK), and keratoconic corneas evaluated by corneal hysteresis and the corneal resistance factor measured with the Reichert Ocular Response Analyzer (ORA). SETTINGS: Instituto Oftalmológico de Alicante, Vissum, Alicante, Spain.
METHODS: Two hundred fifty eyes were divided into 3 groups: normal (control group), post-LASIK, and keratoconus. The corneal biomechanical properties were measured with the ORA, which uses a dynamic bidirectional applanation process. The main outcome measures were intraocular pressure, corneal hysteresis, and the corneal resistance factor.
RESULTS: The control group had 165 eyes; the LASIK group, 65 eyes; and the keratoconus group, 21 eyes. In the control group, the mean corneal hysteresis value was 10.8 mm Hg +/- 1.5 (SD) and the mean corneal resistance factor, 11.0 +/- 1.6 mm Hg. The corneal hysteresis value was lower in older eyes, and the difference between the youngest age group (9 to 14 years) and oldest age group (60 to 80 years) was statistically significant (P = .01, t test). One month after LASIK, corneal hysteresis and the corneal resistance factor decreased significantly, from 10.44 to 9.3 mm Hg and from 10.07 to 8.13 mm Hg, respectively. In the keratoconus group, the mean corneal hysteresis was 7.5 +/- 1.2 mm Hg and the mean corneal resistance factor, 6.2 +/- 1.9 mm Hg. There were statistically significant differences in both biomechanical parameters between keratoconic eyes and post-LASIK eyes (P<.001, t test).
CONCLUSIONS: The corneal hysteresis and corneal resistance factor values were significantly lower in keratoconic eyes than in post-LASIK eyes. Future work is needed to determine whether these differences are useful in detecting keratoconus when other diagnostic tests are equivocal.

Entities:  

Mesh:

Year:  2007        PMID: 17662426     DOI: 10.1016/j.jcrs.2007.04.021

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  97 in total

1.  Evaluation of corneal biomechanical properties following penetrating keratoplasty using the ocular response analyzer.

Authors:  Joo Young Shin; Jin Seok Choi; Joo Youn Oh; Mee Kum Kim; Jin Hak Lee; Won Ryang Wee
Journal:  Korean J Ophthalmol       Date:  2010-06-05

2.  In-vivo corneal biomechanical analysis of unilateral keratoconus.

Authors:  Orhan Ayar; Mehmet Cuneyt Ozmen; Orkun Muftuoglu; Mehmet Orcun Akdemir; Mustafa Koc; Kemal Ozulken
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

3.  Ablation depth and its effects on corneal biomechanical changes in laser in situ keratomileusis and epipolis laser in situ keratomileusis.

Authors:  Lin Zhang; Yan Wang; Xiaoyan Yang
Journal:  Int Ophthalmol       Date:  2013-06-09       Impact factor: 2.031

4.  Serial biomechanical comparison of edematous, normal, and collagen crosslinked human donor corneas using optical coherence elastography.

Authors:  Matthew R Ford; Abhijit Sinha Roy; Andrew M Rollins; William J Dupps
Journal:  J Cataract Refract Surg       Date:  2014-04-24       Impact factor: 3.351

5.  Dynamic contour tonometry over silicone hydrogel contact lens.

Authors:  Andrew K C Lam; Jimmy S H Tse
Journal:  J Optom       Date:  2013-08-28

6.  Biomechanical evaluation of cornea in patients with ankylosing spondylitis.

Authors:  Mehtap Caglayan; Ozge Sarac; Pinar Kosekahya; Sukran Erten; Berna Ayan; Nurullah Cagil
Journal:  Int Ophthalmol       Date:  2016-10-05       Impact factor: 2.031

7.  Corneal hysteresis in post-radial keratotomy primary open-angle glaucoma.

Authors:  Joshua S Hardin; Christopher I Lee; Lydia F Lane; Christian C Hester; R Grant Morshedi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-07-23       Impact factor: 3.117

8.  [Influence of corneal biomechanical properties on myopic regression after laser in situ keratomileusis].

Authors:  D Uthoff; K Hebestedt; G I W Duncker; E Spörl
Journal:  Ophthalmologe       Date:  2013-01       Impact factor: 1.059

9.  Corneal biomechanical properties measured by the ocular response analyzer in acromegalic patients.

Authors:  Emine Sen; Yasemin Tutuncu; Melike Balikoglu-Yilmaz; Ufuk Elgin; Dilek Berker; Faruk Ozturk; Serdar Guler
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-13       Impact factor: 3.117

10.  One-year outcomes of a bilateral randomised prospective clinical trial comparing PRK with mitomycin C and LASIK.

Authors:  A D Wallau; M Campos
Journal:  Br J Ophthalmol       Date:  2009-11-04       Impact factor: 4.638