| Literature DB >> 31303873 |
Dilip Daniel Quadras1, U S Krishna Nayak2, N Suchetha Kumari3, H R Priyadarshini4, Srinivasa Gowda5, Bennete Fernandes6.
Abstract
BACKGROUND: Fixed orthodontic appliances can release metal ions such as nickel, chromium, and zinc into saliva and blood, which can cause contact dermatitis, hypersensitivity, and cytotoxicity. This study was undertaken to assess the release of nickel, chromium, and zinc in saliva and serum of patients undergoing fixed orthodontic treatment.Entities:
Keywords: Chromium; nickel; orthodontic appliances; saliva; zinc
Year: 2019 PMID: 31303873 PMCID: PMC6596177
Source DB: PubMed Journal: Dent Res J (Isfahan) ISSN: 1735-3327
Comparison of mean metal ion levels in saliva and serum among control and study groups before insertion of appliance
| Mean metal ions (ppb) before insertion of appliance | Control group ( | Study group ( | |
|---|---|---|---|
| Salivary nickel level | 4.33±0.002 | 4.24±0.009 | 0.98 |
| Salivary chromium level | 1.13±0.03 | 1.18±0.01 | 0.84 |
| Salivary zinc level | 10.73±1.9 | 11.8±2.4 | 0.53 |
| Serum nickel level | 8.31±0.004 | 8.46±0.008 | 0.91 |
| Serum chromium level | 6.18±0.006 | 6.46±0.008 | 0.42 |
| Serum zinc level | 29.1±1.9 | 28.3±2.3 | 0.26 |
Comparison of mean levels of nickel, chromium, and zinc in saliva and serum among control and study groups at the end of 1.5 years
| Mean metal ions (ppb) at the end of 1.5 years | Control group ( | Study group ( | |
|---|---|---|---|
| Salivary nickel level | 5.02±0.001 | 67±10.8 | 0.021 |
| Salivary chromium level | 1.27±0.09 | 30.8±4.3 | 0.013 |
| Salivary zinc level | 10.24±1.3 | 164.7±10.36 | <0.001 |
| Serum nickel level | 8.47±0.001 | 81.65±3.78 | <0.001 |
| Serum chromium level | 6.02±0.004 | 35.6±2.3 | 0.014 |
| Serum zinc level | 30.1±1.7 | 597.16±68.5 | <0.001 |
Mean nickel, chromium, and zinc levels in saliva at different periods in the study group
| Periods | Nickel (ppb) | Chromium (ppb) | Zinc (ppb) |
|---|---|---|---|
| BA | 4.24±0.009 | 1.18±0.01 | 11.8±2.4 |
| After 1 week | 4.34±0.006 | 0.59±0.026 | 37±3.6 |
| After 3 months | 11.1±0.009 | 1.57±0.08 | 61.6±3.4 |
| After 1 year | 6.84±0.005 | 0.94±0.069 | 84.75±6.85 |
| After 1.5 year | 67±10.8 | 30.8±4.3 | 164.7±10.36 |
| 0.015 | 0.021 | <0.001 |
BA: Before insertion of appliance
Mean nickel, chromium, and zinc levels in serum at different periods in the study group
| Periods | Nickel (ppb) | Chromium (ppb) | Zinc (ppb) |
|---|---|---|---|
| BA | 8.46±0.008 | 6.46±0.008 | 28.3±2.3 |
| After 1 week | 9.08±0.008 | 6.08±0.008 | 55.25±6.5 |
| After 3 months | 6.4±0.006 | 8.4±0.006 | 224±12.6 |
| After 1 year | 7.88±0.005 | 5.88±0.005 | 390.2±32.5 |
| After 1.5 year | 81.65±3.78 | 35.6±2.3 | 597.16±68.5 |
| 0.023 | 0.041 | <0.001 |
BA: Before insertion of appliance