Literature DB >> 6576640

In vitro release of nickel and chromium from simulated orthodontic appliances.

H Y Park, T R Shearer.   

Abstract

The purpose of this experiment was to measure the amounts of nickel and chromium released from a simulated orthodontic appliance incubated in 0.05 percent sodium chloride solution. The average release of metals was 40 micrograms nickel and 36 micrograms chromium per day for a full-mouth appliance. This was well below the average dietary intake of nickel and chromium consumed by Americans. However, the clinician should be aware that release of nickel and chromium from orthodontic bands might sensitize patients to nickel and chromium and may cause hypersensitivity reactions in patients with a prior history of hypersensitivity of these metals.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6576640     DOI: 10.1016/0002-9416(83)90180-x

Source DB:  PubMed          Journal:  Am J Orthod        ISSN: 0002-9416


  31 in total

1.  [The materials engineering characteristics of orthodontic nickel-titanium wires].

Authors:  D Drescher; C Bourauel; M Thier
Journal:  Fortschr Kieferorthop       Date:  1990-12

2.  Nickel ion concentrations in the saliva of patients treated with self-ligating fixed appliances: a prospective cohort study.

Authors:  Lina Gölz; Anna Christine Knickenberg; Ludger Keilig; Susanne Reimann; Spyridon N Papageorgiou; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2016-02-24       Impact factor: 1.938

3.  Release of metal ions from orthodontic appliances: an in vitro study.

Authors:  Marcin Mikulewicz; Katarzyna Chojnacka; Barbara Woźniak; Patrycja Downarowicz
Journal:  Biol Trace Elem Res       Date:  2011-10-20       Impact factor: 3.738

4.  A critical role for thymic stromal lymphopoietin in nickel-induced allergy in mice.

Authors:  Meinar Nur Ashrin; Rieko Arakaki; Akiko Yamada; Tomoyuki Kondo; Mie Kurosawa; Yasusei Kudo; Megumi Watanabe; Tetsuo Ichikawa; Yoshio Hayashi; Naozumi Ishimaru
Journal:  J Immunol       Date:  2014-03-26       Impact factor: 5.422

5.  [New therapeutic possibilities in orthodontics in patients with nickel allergy].

Authors:  J Bachmann
Journal:  Fortschr Kieferorthop       Date:  1987-12

6.  Nickel release from stainless steel and nickel titanium archwires - An in vitro study.

Authors:  Huma D Hussain; Sreedevi D Ajith; Prachi Goel
Journal:  J Oral Biol Craniofac Res       Date:  2016-07-02

7.  [The shearing strength of titanium brackets depending on the coating procedure].

Authors:  N Akin-Nergiz; I Nergiz; U Platzer; K Behlfelt
Journal:  Fortschr Kieferorthop       Date:  1995-01

8.  In vitro investigation into the biological assessment of orthodontic wires.

Authors:  E C Rose; I E Jonas; H F Kappert
Journal:  J Orofac Orthop       Date:  1998       Impact factor: 1.938

9.  In vitro evaluation of surface topographic changes and nickel release of lingual orthodontic archwires.

Authors:  Carlos Suárez; Teresa Vilar; Javier Gil; Pablo Sevilla
Journal:  J Mater Sci Mater Med       Date:  2009-10-14       Impact factor: 3.896

Review 10.  [Tolerance induction towards nickel. From animal model to humans].

Authors:  S Artik; E Gleichmann; T Ruzicka
Journal:  Hautarzt       Date:  2004-11       Impact factor: 0.751

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.