Literature DB >> 11606963

Metal release from simulated fixed orthodontic appliances.

C J Hwang1, J S Shin, J Y Cha.   

Abstract

Most orthodontic appliances and archwires are stainless steel or nickel-titanium (NiTi) alloys that can release metal ions, with saliva as the medium. To measure metal released from the fixed orthodontic appliances currently in use, we fabricated simulated fixed orthodontic appliances that corresponded to half of the maxillary arch and soaked them in 50 mL of artificial saliva (pH 6.75 +/- 0.15, 37 degrees C) for 3 months. We used brackets, tubes, and bands made by Tomy (Tokyo, Japan). Four groups were established according to the appliance manufacturer and the type of metal in the .016 x .022-in archwires. Groups A and B were stainless steel archwires from Ormco (Glendora, Calif) and Dentaurum (Ispringen, Germany), respectively, and groups C and D were both NiTi archwires with Ormco's copper NiTi and Tomy's Bioforce sentalloy, respectively. Stainless steel archwires were heat treated in an electric furnace at 500 degrees C for 1 minute and quenched in water. We measured the amount of metal released from each group by immersion time. Our conclusions were as follows: (1) there was no increase in the amount of chromium released after 4 weeks in group A, 2 weeks in group B, 3 weeks in group C, and 8 weeks in group D; (2) there was no increase in the amount of nickel released after 2 weeks in group A, 3 days in group B, 7 days in group C, and 3 weeks in group D; and (3) there was no increase in the amount of iron released after 2 weeks in group A, 3 days in group B, and 1 day in groups C and D. In our 3-month-long investigation, we saw a decrease in metal released as immersion time increased.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11606963     DOI: 10.1067/mod.2001.117911

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  24 in total

1.  Release of metal ions from orthodontic appliances: an in vitro study.

Authors:  Marcin Mikulewicz; Katarzyna Chojnacka; Barbara Woźniak; Patrycja Downarowicz
Journal:  Biol Trace Elem Res       Date:  2011-10-20       Impact factor: 3.738

2.  Nickel release from stainless steel and nickel titanium archwires - An in vitro study.

Authors:  Huma D Hussain; Sreedevi D Ajith; Prachi Goel
Journal:  J Oral Biol Craniofac Res       Date:  2016-07-02

3.  In vitro evaluation of surface topographic changes and nickel release of lingual orthodontic archwires.

Authors:  Carlos Suárez; Teresa Vilar; Javier Gil; Pablo Sevilla
Journal:  J Mater Sci Mater Med       Date:  2009-10-14       Impact factor: 3.896

4.  Corrosion behavior of self-ligating and conventional metal brackets.

Authors:  Lúcio Henrique Esmeraldo Gurgel Maia; Hibernon Lopes Filho; Antônio Carlos de Oliveira Ruellas; Mônica Tirre de Souza Araújo; Delmo Santiago Vaitsman
Journal:  Dental Press J Orthod       Date:  2014 Mar-Apr

5.  Estimation of Release of Nickel and Chromium by Indian Made Orthodontic Appliance in Saliva.

Authors:  Sandeep Parashar; Rajkumar Maurya; Ankur Gupta; Chatura Hegde; Neelima Anand
Journal:  J Clin Diagn Res       Date:  2015-09-01

6.  Biomonitorization of metal ions in the serum of Iranian patients treated with fixed orthodontic appliances in comparison with controls in eastern Iran.

Authors:  Mahdjoube Goldani Moghadam; Reyhane Hoshyar; Marcin Mikulewicz; Katarzyna Chojnacka; Geir Bjørklund; Joeri J Pen; Nammam Ali Azadi; Maghdad Pirsaheb; Meysam Dashtaki; Borhan Mansouri
Journal:  Environ Sci Pollut Res Int       Date:  2019-09-14       Impact factor: 4.223

7.  Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants.

Authors:  Celha Borges Costa Alves; Márcio Nunes Segurado; Miriam Cristina Leandro Dorta; Fátima Ribeiro Dias; Maurício Guilherme Lenza; Marcos Augusto Lenza
Journal:  Dental Press J Orthod       Date:  2016 Sep-Oct

8.  Effect of Mobile Phone Usage on Nickel Ions Release and pH of Saliva in Patients Undergoing Fixed Orthodontic Treatment.

Authors:  Lalita Girish Nanjannawar; Tejashree Suresh Girme; Jiwanasha Manish Agrawal; Manish Suresh Agrawal; Sangamesh Gurunath Fulari; Shraddha Subhash Shetti; Vishwal Ajith Kagi
Journal:  J Clin Diagn Res       Date:  2017-09-01

9.  Release of metal ions from fixed orthodontic appliance: an in vitro study in continuous flow system.

Authors:  Marcin Mikulewicz; Katarzyna Chojnacka; Paulina Wołowiec
Journal:  Angle Orthod       Date:  2013-03-11       Impact factor: 2.079

10.  Effect of nickel chloride on cell proliferation.

Authors:  Vincenzo D'Antò; Rosa Valletta; Massimo Amato; Helmut Schweikl; Michele Simeone; Sergio Paduano; Sandro Rengo; Gianrico Spagnuolo
Journal:  Open Dent J       Date:  2012-11-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.