Literature DB >> 10399412

Ion release from orthodontic appliances.

N Staffolani1, F Damiani, C Lilli, M Guerra, N J Staffolani, S Belcastro, P Locci.   

Abstract

OBJECTIVE: The microbiological and enzymatic characteristics of the oral cavity would seem to provide a suitable environment for the corrosion of metals. We assayed the release of metal ions from one orthodontic appliance which included two 304 and 316 steel molar bands, ten 316 steel brackets, one nickel-titanium archwire and a brazing alloy to connect the elements of molar bands and brackets.
METHODS: The orthodontic appliance was dipped in both inorganic (pH 3.5-6.5) and organic acid solutions (w/v 1% each of tartaric, citric and ascorbic acid at pH 2.2 or 1.5% each of lactic and acetic acid at pH 2.5). The release of nickel (Ni), chromium (Cr), copper (Cu), silver (Ag) and palladium (Pd) was determined using an atomic absorption spectrophotometer Varian AA 10.
RESULTS: The release of Ni, Cr and Cu was markedly less at pH 6.5 than at pH 3.5 at all time points in acid solution. Daily release/single appliance after the first day decreased. Contrary to expectations, appliances immersed in organic acid solutions at pH 2.2 or 2.5 after 28 days generally released an amount of ions similar to that observed in inorganic acid solution at pH 3.5, with the exception of Cu. Release of silver and palladium, two metals present in the brazing alloy, proved to be very low (approximately 0.2 microgram after 28 days).
CONCLUSIONS: The daily release of Ni, Cu and Cr by an orthodontic appliance in acid pH, particularly favourable to corrosion, was well below that ingested with a normal daily diet. It is therefore concluded that the quantities of metal ions released in our experimental conditions should not be cause for concern in utilising the appliance.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10399412     DOI: 10.1016/s0300-5712(98)00073-6

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  20 in total

1.  Nickel ion concentrations in the saliva of patients treated with self-ligating fixed appliances: a prospective cohort study.

Authors:  Lina Gölz; Anna Christine Knickenberg; Ludger Keilig; Susanne Reimann; Spyridon N Papageorgiou; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2016-02-24       Impact factor: 1.938

Review 2.  Nickel-free austenitic stainless steels for medical applications.

Authors:  Ke Yang; Yibin Ren
Journal:  Sci Technol Adv Mater       Date:  2010-02-26       Impact factor: 8.090

3.  Metallurgical characterization of experimental Ag-based soldering alloys.

Authors:  Argyro Ntasi; Youssef S Al Jabbari; Nick Silikas; Sara M Al Taweel; Spiros Zinelis
Journal:  Saudi Dent J       Date:  2014-06-24

4.  Specific biofunctional performances of the hydroxyapatite-sodium maleate copolymer hybrid coating nanostructures evaluated by in vitro studies.

Authors:  L E Sima; A Filimon; R M Piticescu; G C Chitanu; D M Suflet; M Miroiu; G Socol; I N Mihailescu; J Neamtu; G Negroiu
Journal:  J Mater Sci Mater Med       Date:  2009-06-20       Impact factor: 3.896

Review 5.  Corrosion degradation and prevention by surface modification of biometallic materials.

Authors:  Raghuvir Singh; Narendra B Dahotre
Journal:  J Mater Sci Mater Med       Date:  2006-12-02       Impact factor: 4.727

6.  Evaluation of Nickel and Chromium Ion Release During Fixed Orthodontic Treatment Using Inductively Coupled Plasma-Mass Spectrometer: An In Vivo Study.

Authors:  Rabindra S Nayak; Bharti Khanna; Azam Pasha; K Vinay; Anjali Narayan; K Chaitra
Journal:  J Int Oral Health       Date:  2015-08

7.  Variations in surface roughness of seven orthodontic archwires: an SEM-profilometry study.

Authors:  Fariborz Amini; Vahid Rakhshan; Maryam Pousti; Hajir Rahimi; Mahsa Shariati; Bahareh Aghamohamadi
Journal:  Korean J Orthod       Date:  2012-06-28       Impact factor: 1.372

8.  Urinary levels of nickel and chromium associated with dental restoration by nickel-chromium based alloys.

Authors:  Bo Chen; Gang Xia; Xin-Ming Cao; Jue Wang; Bi-Yao Xu; Pu Huang; Yue Chen; Qing-Wu Jiang
Journal:  Int J Oral Sci       Date:  2013-04-12       Impact factor: 6.344

9.  Oral factors affecting titanium elution and corrosion: an in vitro study using simulated body fluid.

Authors:  Hideki Suito; Yuki Iwawaki; Takaharu Goto; Yoritoki Tomotake; Tetsuo Ichikawa
Journal:  PLoS One       Date:  2013-06-07       Impact factor: 3.240

10.  Metallurgical and electrochemical characterization of contemporary silver-based soldering alloys.

Authors:  Argyro Ntasi; Youssef Al Jabbari; Wolf Dieter Mueller; George Eliades; Spiros Zinelis
Journal:  Angle Orthod       Date:  2013-11-07       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.