Literature DB >> 14718875

Characterization and cytotoxicity of ions released from stainless steel and nickel-titanium orthodontic alloys.

Theodore Eliades1, Harris Pratsinis, Dimitris Kletsas, George Eliades, Margarita Makou.   

Abstract

The purpose of this study was to qualitatively and quantitatively characterize the substances released from orthodontic brackets and nickel-titanium wires and to comparatively assess the cytotoxicity of the ions released from these orthodontic alloys. Two full sets of stainless steel brackets of 20 brackets each (weight 2.1 g) and 2 groups of 0.018 x 0.025 Ni-Ti archwires of 10 wires each (weight 2.0 g) were immersed in 0.9% saline solution for a month. The immersion media were analyzed with inductively coupled plasma-atomic emission spectroscopy (ICP-AES), and the ionic content was statistically analyzed with 1-way analysis of variance (ANOVA). Human periodontal ligament fibroblasts and gingival fibroblasts were exposed to various concentrations of the 2 immersion media; nickel chloride was used as a positive control for comparison purposes. The cytotoxic or cytostatic activity of the media was investigated with the MTT and the DNA synthesis assays. The results of the cytotoxicity assay were analyzed with 2-way ANOVA and the Tukey test with solution and concentration variants as discriminating variables (alpha=0.05). The results indicated no ionic release for the nickel-titanium alloy aging solution, whereas measurable nickel and traces of chromium were found in the stainless steel bracket-aging medium. Concentrations of the nickel chloride solution greater then 2 mM were found to reduce by more than 50% the viability and DNA synthesis of fibroblasts; however, neither orthodontic materials-derived media had any effect on the survival and DNA synthesis of either cells.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14718875     DOI: 10.1016/j.ajodo.2003.09.009

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  22 in total

1.  In vitro studies on ultrasmall superparamagnetic iron oxide nanoparticles coated with gummic acid for T2 MRI contrast agent.

Authors:  I Rabias; H Pratsinis; G Drossopoulou; M Fardis; T Maris; N Boukos; N Tsotakos; D Kletsas; E Tsilibary; G Papavassiliou
Journal:  Biomicrofluidics       Date:  2007-11-30       Impact factor: 2.800

2.  Biocompatibility of orthodontic bands following exposure to dental plaque.

Authors:  Sandra Hornikel; Christina Erbe; Irene Schmidtmann; Heiner Wehrbein
Journal:  J Orofac Orthop       Date:  2011-04-20       Impact factor: 1.938

3.  Differences in cytocompatibility, dynamics of the oxide layers' formation, and nickel release between superelastic and thermo-activated nickel-titanium archwires.

Authors:  Miodrag Čolić; Sergej Tomić; Rebeka Rudolf; Evgenija Marković; Ivana Šćepan
Journal:  J Mater Sci Mater Med       Date:  2016-06-30       Impact factor: 3.896

Review 4.  Nickel-free austenitic stainless steels for medical applications.

Authors:  Ke Yang; Yibin Ren
Journal:  Sci Technol Adv Mater       Date:  2010-02-26       Impact factor: 8.090

5.  Cytotoxic evaluation of two orthodontic silver solder materials on human periodontal ligament fibroblast cells and the effects of antioxidant and antiapoptotic reagents.

Authors:  Ghada Nimeri; Joseph Curry; David Berzins; Dawei Liu; Bhoomika Ahuja; Douglas Lobner
Journal:  Angle Orthod       Date:  2021-05-01       Impact factor: 2.079

6.  Evaluation of the cytotoxicity of fiber reinforced composite bonded retainers and flexible spiral wires retainers in simulated high and low cariogenic environments.

Authors:  Arezoo Jahanbin; Mostafa Shahabi; Farzaneh Ahrari; Yasaman Bozorgnia; Arezoo Shajiei; Hooman Shafaee; Jalil Tavakkol Afshari
Journal:  J Orthod Sci       Date:  2015 Jan-Mar

7.  Evaluation of Nickel and Chromium Ion Release During Fixed Orthodontic Treatment Using Inductively Coupled Plasma-Mass Spectrometer: An In Vivo Study.

Authors:  Rabindra S Nayak; Bharti Khanna; Azam Pasha; K Vinay; Anjali Narayan; K Chaitra
Journal:  J Int Oral Health       Date:  2015-08

8.  Effect of Mobile Phone Usage on Nickel Ions Release and pH of Saliva in Patients Undergoing Fixed Orthodontic Treatment.

Authors:  Lalita Girish Nanjannawar; Tejashree Suresh Girme; Jiwanasha Manish Agrawal; Manish Suresh Agrawal; Sangamesh Gurunath Fulari; Shraddha Subhash Shetti; Vishwal Ajith Kagi
Journal:  J Clin Diagn Res       Date:  2017-09-01

9.  Differences of cytotoxicity of orthodontic bands assessed by survival tests in Saccharomyces cerevisiae.

Authors:  Tatiana Siqueira Gonçalves; Luciane Macedo de Menezes; Luciele Gonzaga Ribeiro; Catieli Gobetti Lindholz; Renata Medina-Silva
Journal:  Biomed Res Int       Date:  2014-01-06       Impact factor: 3.411

10.  DNA damage in oral mucosa cells of patients with fixed orthodontic appliances.

Authors:  Farzin Heravi; Mohammad Reza Abbaszadegan; Mohsen Merati; Nadia Hasanzadeh; Ezzat Dadkhah; Farzaneh Ahrari
Journal:  J Dent (Tehran)       Date:  2013-11-30
View more