Literature DB >> 11686446

An iterative maximum-likelihood polychromatic algorithm for CT.

B De Man1, J Nuyts, P Dupont, G Marchal, P Suetens.   

Abstract

A new iterative maximum-likelihood reconstruction algorithm for X-ray computed tomography is presented. The algorithm prevents beam hardening artifacts by incorporating a polychromatic acquisition model. The continuous spectrum of the X-ray tube is modeled as a number of discrete energies. The energy dependence of the attenuation is taken into account by decomposing the linear attenuation coefficient into a photoelectric component and a Compton scatter component. The relative weight of these components is constrained based on prior material assumptions. Excellent results are obtained for simulations and for phantom measurements. Beam-hardening artifacts are effectively eliminated. The relation with existing algorithms is discussed. The results confirm that improving the acquisition model assumed by the reconstruction algorithm results in reduced artifacts. Preliminary results indicate that metal artifact reduction is a very promising application for this new algorithm.

Entities:  

Mesh:

Year:  2001        PMID: 11686446     DOI: 10.1109/42.959297

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  65 in total

Review 1.  Application of polychromatic µCT for mineral density determination.

Authors:  W Zou; N Hunter; M V Swain
Journal:  J Dent Res       Date:  2010-09-21       Impact factor: 6.116

2.  Comparison of iterative model, hybrid iterative, and filtered back projection reconstruction techniques in low-dose brain CT: impact of thin-slice imaging.

Authors:  Takeshi Nakaura; Yuji Iyama; Masafumi Kidoh; Koichi Yokoyama; Seitaro Oda; Shinichi Tokuyasu; Kazunori Harada; Yasuyuki Yamashita
Journal:  Neuroradiology       Date:  2015-12-29       Impact factor: 2.804

3.  Improved Image Quality in Head and Neck CT Using a 3D Iterative Approach to Reduce Metal Artifact.

Authors:  W Wuest; M S May; M Brand; N Bayerl; A Krauss; M Uder; M Lell
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-13       Impact factor: 3.825

4.  Experimental spectral measurements of heavy K-edge filtered beams for x-ray computed mammotomography.

Authors:  D J Crotty; R L McKinley; M P Tornai
Journal:  Phys Med Biol       Date:  2007-01-10       Impact factor: 3.609

5.  Achieving accurate radiochromic optical-CT imaging when using a polychromatic light source.

Authors:  A Thomas; M Pierquet; M Oldham
Journal:  J Phys Conf Ser       Date:  2010

6.  Dual energy CT for attenuation correction with PET/CT.

Authors:  Ting Xia; Adam M Alessio; Paul E Kinahan
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

7.  Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: comparison of analytic and polyenergetic statistical reconstruction algorithms.

Authors:  Joshua D Evans; Bruce R Whiting; Joseph A O'Sullivan; David G Politte; Paul H Klahr; Yaduo Yu; Jeffrey F Williamson
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

8.  Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration.

Authors:  Wei Zhou; David J Bartlett; Felix E Diehn; Katrina N Glazebrook; Amy L Kotsenas; Rickey E Carter; Joel G Fletcher; Cynthia H McCollough; Shuai Leng
Journal:  Invest Radiol       Date:  2019-04       Impact factor: 6.016

Review 9.  Artefacts in CBCT: a review.

Authors:  R Schulze; U Heil; D Gross; D D Bruellmann; E Dranischnikow; U Schwanecke; E Schoemer
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

10.  The effects of the orthopedic metal artifact reduction (O-MAR) algorithm on contouring and dosimetry of head and neck radiotherapy patients.

Authors:  Jussi Sillanpaa; Michael Lovelock; Boris Mueller
Journal:  Med Dosim       Date:  2019-07-30       Impact factor: 1.482

View more