Literature DB >> 28230539

Polyenergetic known-component CT reconstruction with unknown material compositions and unknown x-ray spectra.

S Xu1, A Uneri, A Jay Khanna, J H Siewerdsen, J W Stayman.   

Abstract

Metal artifacts can cause substantial image quality issues in computed tomography. This is particularly true in interventional imaging where surgical tools or metal implants are in the field-of-view. Moreover, the region-of-interest is often near such devices which is exactly where image quality degradations are largest. Previous work on known-component reconstruction (KCR) has shown the incorporation of a physical model (e.g. shape, material composition, etc) of the metal component into the reconstruction algorithm can significantly reduce artifacts even near the edge of a metal component. However, for such approaches to be effective, they must have an accurate model of the component that include energy-dependent properties of both the metal device and the CT scanner, placing a burden on system characterization and component material knowledge. In this work, we propose a modified KCR approach that adopts a mixed forward model with a polyenergetic model for the component and a monoenergetic model for the background anatomy. This new approach called Poly-KCR jointly estimates a spectral transfer function associated with known components in addition to the background attenuation values. Thus, this approach eliminates both the need to know component material composition a prior as well as the requirement for an energy-dependent characterization of the CT scanner. We demonstrate the efficacy of this novel approach and illustrate its improved performance over traditional and model-based iterative reconstruction methods in both simulation studies and in physical data including an implanted cadaver sample.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28230539      PMCID: PMC5728157          DOI: 10.1088/1361-6560/aa6285

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  34 in total

1.  Monotonic algorithms for transmission tomography.

Authors:  H Erdoğan; J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1999-09       Impact factor: 10.048

2.  Frequency split metal artifact reduction (FSMAR) in computed tomography.

Authors:  Esther Meyer; Rainer Raupach; Michael Lell; Bernhard Schmidt; Marc Kachelrieß
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

3.  CT metal artifact reduction method correcting for beam hardening and missing projections.

Authors:  Joost M Verburg; Joao Seco
Journal:  Phys Med Biol       Date:  2012-04-18       Impact factor: 3.609

4.  A generalized Gaussian image model for edge-preserving MAP estimation.

Authors:  C Bouman; K Sauer
Journal:  IEEE Trans Image Process       Date:  1993       Impact factor: 10.856

5.  A novel forward projection-based metal artifact reduction method for flat-detector computed tomography.

Authors:  Daniel Prell; Yiannis Kyriakou; Marcel Beister; Willi A Kalender
Journal:  Phys Med Biol       Date:  2009-10-14       Impact factor: 3.609

6.  Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction.

Authors:  Jeffrey F Williamson; Bruce R Whiting; Jasenka Benac; Ryan J Murphy; G James Blaine; Joseph A O'Sullivan; David G Politte; Donald L Snyder
Journal:  Med Phys       Date:  2002-10       Impact factor: 4.071

7.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

8.  Prior-based artifact correction (PBAC) in computed tomography.

Authors:  Thorsten Heußer; Marcus Brehm; Ludwig Ritschl; Stefan Sawall; Marc Kachelrieß
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

9.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

10.  Metal artifact suppression from reformatted projections in multislice helical CT using dual-front active contours.

Authors:  Hua Li; Lifeng Yu; Xin Liu; Joel G Fletcher; Cynthia H McCollough
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

View more
  8 in total

1.  Known-component 3D image reconstruction for improved intraoperative imaging in spine surgery: A clinical pilot study.

Authors:  Xiaoxuan Zhang; Ali Uneri; J Webster Stayman; Corinna C Zygourakis; Sheng-Fu L Lo; Nicholas Theodore; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2019-06-30       Impact factor: 4.071

2.  Known-component metal artifact reduction (KC-MAR) for cone-beam CT.

Authors:  A Uneri; X Zhang; T Yi; J W Stayman; P A Helm; G M Osgood; N Theodore; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2019-08-21       Impact factor: 3.609

3.  Model-based three-material decomposition in dual-energy CT using the volume conservation constraint.

Authors:  Stephen Z Liu; Matthew Tivnan; Greg M Osgood; Jeffrey H Siewerdsen; J Webster Stayman; Wojciech Zbijewski
Journal:  Phys Med Biol       Date:  2022-07-08       Impact factor: 4.174

4.  Improving Structure Delineation for Radiation Therapy Planning Using Dual-Energy CT.

Authors:  George Noid; Justin Zhu; An Tai; Nilesh Mistry; Diane Schott; Douglas Prah; Eric Paulson; Christopher Schultz; X Allen Li
Journal:  Front Oncol       Date:  2020-08-28       Impact factor: 6.244

5.  Dual-energy CT imaging of nasopharyngeal cancer cells using multifunctional gold nanoparticles.

Authors:  Sara Khademi; Saeed Sarkar; Ali Shakeri-Zadeh; Neda Attaran; Sharmin Kharrazi; Razieh Solgi; Mohammad Reza Ay; Hosein Azimian; Hossein Ghadiri
Journal:  IET Nanobiotechnol       Date:  2019-12       Impact factor: 1.847

6.  Model-based dual-energy tomographic image reconstruction of objects containing known metal components.

Authors:  Stephen Z Liu; Qian Cao; Matthew Tivnan; Steven Tilley Ii; Jeffrey H Siewerdsen; J Webster Stayman; Wojciech Zbijewski
Journal:  Phys Med Biol       Date:  2020-12-22       Impact factor: 4.174

7.  Deformable Known Component Model-Based Reconstruction for Coronary CT Angiography.

Authors:  X Zhang; S Tilley; S Xu; A Mathews; E R McVeigh; J W Stayman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

8.  Polyenergetic Known-Component Reconstruction without Prior Shape Models.

Authors:  C Zhang; W Zbijewski; X Zhang; S Xu; J W Stayman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.