Literature DB >> 17368220

A segmentation-based method for metal artifact reduction.

Hengyong Yu1, Kai Zeng, Deepak K Bharkhada, Ge Wang, Mark T Madsen, Osama Saba, Bruno Policeni, Matthew A Howard, Wendy R K Smoker.   

Abstract

RATIONALE AND
OBJECTIVES: We propose a novel segmentation-based interpolation method to reduce the metal artifacts caused by surgical aneurysm clips.
MATERIALS AND METHODS: Our method consists of five steps: coarse image reconstruction, metallic object segmentation, forward-projection, projection interpolation, and final image reconstruction. The major innovations are 2-fold. First, a state-of-the-art mean-shift technique in the computer vision field is used to improve the accuracy of the metallic object segmentation. Second, a feedback strategy is developed in the interpolation step to adjust the interpolated value based on the prior knowledge that the interpolated values should not be larger than the original ones. Physical phantom and real patient datasets are studied to evaluate the efficacy of our method.
RESULTS: Compared to the state-of-the-art segmentation-based method designed previously, our method reduces the metal artifacts by 20-40% in terms of the standard deviation and provides more information for the assessment of soft tissues and osseous structures surrounding the surgical clips.
CONCLUSION: Mean shift technique and feedback strategy can help to improve the image quality in terms of reducing metal artifacts.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17368220      PMCID: PMC1995751          DOI: 10.1016/j.acra.2006.12.015

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  10 in total

1.  X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses.

Authors:  S Zhao; D D Robertson; G Wang; B Whiting; K T Bae
Journal:  IEEE Trans Med Imaging       Date:  2000-12       Impact factor: 10.048

2.  Iterative X-ray Cone-Beam Tomography for Metal Artifact Reduction and Local Region Reconstruction.

Authors: 
Journal:  Microsc Microanal       Date:  1999-01       Impact factor: 4.127

3.  Single-slice rebinning method for helical cone-beam CT.

Authors:  F Noo; M Defrise; R Clackdoyle
Journal:  Phys Med Biol       Date:  1999-02       Impact factor: 3.609

4.  A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images.

Authors:  Oliver Watzke; Willi A Kalender
Journal:  Eur Radiol       Date:  2004-03-11       Impact factor: 5.315

5.  X-ray CT high-density artefact suppression in the presence of bones.

Authors:  Jikun Wei; Laigao Chen; George A Sandison; Yun Liang; Lisa X Xu
Journal:  Phys Med Biol       Date:  2004-12-21       Impact factor: 3.609

6.  An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: experimental and clinical studies.

Authors:  Mehran Yazdi; Mehran Yazdia; Luc Gingras; Luc Beaulieu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-07-15       Impact factor: 7.038

7.  Iterative deblurring for CT metal artifact reduction.

Authors:  G Wang; D L Snyder; J A O'Sullivan; M W Vannier
Journal:  IEEE Trans Med Imaging       Date:  1996       Impact factor: 10.048

8.  Reduction of CT artifacts caused by metallic implants.

Authors:  W A Kalender; R Hebel; J Ebersberger
Journal:  Radiology       Date:  1987-08       Impact factor: 11.105

9.  Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering.

Authors:  Matthieu Bal; Lothar Spies
Journal:  Med Phys       Date:  2006-08       Impact factor: 4.071

10.  A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement.

Authors:  Andreas H Mahnken; Rainer Raupach; Joachim E Wildberger; Bettina Jung; Nicole Heussen; Thomas G Flohr; Rolf W Günther; Stefan Schaller
Journal:  Invest Radiol       Date:  2003-12       Impact factor: 6.016

  10 in total
  19 in total

1.  Metallic artefact reduction with monoenergetic dual-energy CT: systematic ex vivo evaluation of posterior spinal fusion implants from various vendors and different spine levels.

Authors:  R Guggenberger; S Winklhofer; G Osterhoff; G A Wanner; M Fortunati; G Andreisek; H Alkadhi; P Stolzmann
Journal:  Eur Radiol       Date:  2012-05-30       Impact factor: 5.315

2.  Qualitative and quantitative assessment of metal artifacts arising from implantable cardiac pacing devices in oncological PET/CT studies: a phantom study.

Authors:  Mohammad R Ay; Abolfazl Mehranian; Mehrsima Abdoli; Pardis Ghafarian; Habib Zaidi
Journal:  Mol Imaging Biol       Date:  2011-12       Impact factor: 3.488

3.  Reduction of metallic coil artefacts in computed tomography body imaging: effects of a new single-energy metal artefact reduction algorithm.

Authors:  Masafumi Kidoh; Daisuke Utsunomiya; Osamu Ikeda; Yoshitaka Tamura; Seitaro Oda; Yoshinori Funama; Hideaki Yuki; Takeshi Nakaura; Takayuki Kawano; Toshinori Hirai; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2015-08-14       Impact factor: 5.315

4.  Model Image-Based Metal Artifact Reduction for Computed Tomography.

Authors:  Dmytro Luzhbin; Jay Wu
Journal:  J Digit Imaging       Date:  2020-02       Impact factor: 4.056

5.  Inpainting-filtering for metal artifact reduction (IMIF-MAR) in computed tomography.

Authors:  Yakdiel Rodríguez-Gallo; Rubén Orozco-Morales; Marlen Pérez-Díaz
Journal:  Phys Eng Sci Med       Date:  2021-03-24

6.  Known-component metal artifact reduction (KC-MAR) for cone-beam CT.

Authors:  A Uneri; X Zhang; T Yi; J W Stayman; P A Helm; G M Osgood; N Theodore; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2019-08-21       Impact factor: 3.609

7.  Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy.

Authors:  Hua Li; Camille Noel; Haijian Chen; H Harold Li; Daniel Low; Kevin Moore; Paul Klahr; Jeff Michalski; Hiram A Gay; Wade Thorstad; Sasa Mutic
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

8.  Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography.

Authors:  Yanbo Zhang; Hengyong Yu
Journal:  IEEE Trans Med Imaging       Date:  2018-06       Impact factor: 10.048

9.  Added value of a single-energy projection-based metal-artifact reduction algorithm for the computed tomography evaluation of oral cavity cancers.

Authors:  Kenichiro Hirata; Daisuke Utsunomiya; Seitaro Oda; Masafumi Kidoh; Yoshinori Funama; Hideaki Yuki; Morikatsu Yoshida; Yasuyuki Yamashita
Journal:  Jpn J Radiol       Date:  2015-08-19       Impact factor: 2.374

10.  Metal artifact reduction from reformatted projections for hip prostheses in multislice helical computed tomography: techniques and initial clinical results.

Authors:  Lifeng Yu; Hua Li; Jan Mueller; James M Kofler; Xin Liu; Andrew N Primak; Joel G Fletcher; Luis S Guimaraes; Thanila Macedo; Cynthia H McCollough
Journal:  Invest Radiol       Date:  2009-11       Impact factor: 6.016

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.