Literature DB >> 778862

Beam hardening in x-ray reconstructive tomography.

R A Brooks, G Di Chiro.   

Abstract

As a polychromatic X-ray beam passes through matter, low energy photons are preferentially absorbed, and the (logarithmic) attenuation is no longer a linear function of absorber thickness. This leads to various artifacts in reconstructive tomography. If a water bag is used, the nonlinear attenuation in bone causes a distortion of the bone values and a spill-over inside the skull, or 'pseudo-cortex' artifact. If no water bag is used, there is an additional effect due to the varying thickness of soft tissue which causes a depression of interior values, or 'cupping'. Both artifacts can be remedied by additional prefiltering of the beam and by applying a linearization correction to the detector outputs.

Entities:  

Mesh:

Year:  1976        PMID: 778862     DOI: 10.1088/0031-9155/21/3/004

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  57 in total

1.  Soft tissue variations influence HR-pQCT density measurements in a spatially dependent manner.

Authors:  Po-Hung Wu; Tanvi Gupta; Hanling Chang; Dimitry Petrenko; Anne Schafer; Galateia Kazakia
Journal:  Bone       Date:  2020-06-27       Impact factor: 4.398

2.  Characterization and correction of cupping effect artefacts in cone beam CT.

Authors:  A K Hunter; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2012-03       Impact factor: 2.419

3.  Modulator design for x-ray scatter correction using primary modulation: material selection.

Authors:  Hewei Gao; Lei Zhu; Rebecca Fahrig
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

4.  Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment.

Authors:  Kazuki Takegami; Hiroaki Hayashi; Hiroki Okino; Natsumi Kimoto; Itsumi Maehata; Yuki Kanazawa; Tohru Okazaki; Takuya Hashizume; Ikuo Kobayashi
Journal:  Radiol Phys Technol       Date:  2015-11-20

Review 5.  Advances in stress cardiac MRI and computed tomography.

Authors:  Yasmin S Hamirani; Christopher M Kramer
Journal:  Future Cardiol       Date:  2013-09

6.  Adaptive correction of the pseudo-enhancement of CT attenuation for fecal-tagging CT colonography.

Authors:  Janne Näppi; Hiroyuki Yoshida
Journal:  Med Image Anal       Date:  2008-01-26       Impact factor: 8.545

7.  Development of a theory for generating regional cardiac perfusion images during coronary angiography in the coronary angiography lab.

Authors:  Takuya Sakaguchi; Takashi Ichihara; Jeffrey C Trost; Omair Yousuf; Joao A C Lima; Jingwu Yao; Richard T George
Journal:  Int J Cardiovasc Imaging       Date:  2013-10-12       Impact factor: 2.357

8.  Fast analytical approach of application specific dose efficient spectrum selection for diagnostic CT imaging and PET attenuation correction.

Authors:  Xue Rui; Yannan Jin; Paul F FitzGerald; Mingye Wu; Adam M Alessio; Paul E Kinahan; Bruno De Man
Journal:  Phys Med Biol       Date:  2016-10-18       Impact factor: 3.609

9.  Multi-material decomposition using statistical image reconstruction for spectral CT.

Authors:  Yong Long; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-04-25       Impact factor: 10.048

Review 10.  Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

Authors:  Benjamin M Yeh; Paul F FitzGerald; Peter M Edic; Jack W Lambert; Robert E Colborn; Michael E Marino; Paul M Evans; Jeannette C Roberts; Zhen J Wang; Margaret J Wong; Peter J Bonitatibus
Journal:  Adv Drug Deliv Rev       Date:  2016-09-09       Impact factor: 15.470

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.