Abstract

The objective of this paper is to provide recommendations towards the appropriate use of thyroid shielding in dental cone beam CT (CBCT). Based on current evidence of thyroid radiosensitivity, dosimetric data in the presence and absence of shielding, and a depiction of potential adverse effects of thyroid shielding, a concise set of recommendations was prepared. According to current risk models, thyroid sensitivity is particularly high at a young age, and much higher for females. In the literature, involving adult male, female and paediatric reference phantoms, the use of a tightly fitted thyroid collar with a lead-equivalent thickness of at least 0.25 mm has consistently shown a significant reduction (average: 45.9%) of the equivalent dose to the thyroid. It can therefore be recommended that thyroid shielding should be routinely used for children undergoing CBCT scanning and is recommended for adults up to the age of 50. The increase of the X-ray tube current from automatic exposure control systems due to thyroid shielding can be avoided by placing the shielding collar after acquiring the scout images. Should real-time tube current modulation be implemented in dental CBCT imaging in the future, perspectives regarding the appropriate use of shielding may change according to current trends in CT. In view of the manifestation of metal artefacts, shielding is best avoided if radiological evaluation of tissues below the lower border of the mandible is needed.

Entities:  

Keywords:  cone beam CT; radiation dose; radiation protection; thyroid; thyroid collar

Mesh:

Year:  2019        PMID: 31237774      PMCID: PMC6775792          DOI: 10.1259/dmfr.20190014

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  15 in total

1.  Dose reduction in maxillofacial imaging using low dose Cone Beam CT.

Authors:  Kostas Tsiklakis; Catherine Donta; Sophia Gavala; Kety Karayianni; Vasiliki Kamenopoulou; Costas J Hourdakis
Journal:  Eur J Radiol       Date:  2005-06-22       Impact factor: 3.528

2.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

Review 3.  What have we learnt from Chernobyl? What have we still to learn?

Authors:  G A Thomas; M D Tronko; A F Tsyb; R M Tuttle
Journal:  Clin Oncol (R Coll Radiol)       Date:  2011-02-24       Impact factor: 4.126

4.  Dose optimization for assessment of periodontal structures in cone beam CT examinations.

Authors:  Ayman Al-Okshi; Chrysoula Theodorakou; Christina Lindh
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

5.  Effect of leaded glasses and thyroid shielding on cone beam CT radiation dose in an adult female phantom.

Authors:  A D Goren; R D Prins; L T Dauer; B Quinn; A Al-Najjar; R D Faber; G Patchell; I Branets; D C Colosi
Journal:  Dentomaxillofac Radiol       Date:  2013-02-14       Impact factor: 2.419

6.  The Image Gently in Dentistry campaign: promotion of responsible use of maxillofacial radiology in dentistry for children.

Authors:  Stuart C White; William C Scarfe; Ralf K W Schulze; Alan G Lurie; Joanna M Douglass; Allan G Farman; Clarice S Law; Martin D Levin; Robert A Sauer; Richard W Valachovic; Gregory G Zeller; Marilyn J Goske
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2014-06-16

7.  Effective radiation dose and eye lens dose in dental cone beam CT: effect of field of view and angle of rotation.

Authors:  R Pauwels; G Zhang; C Theodorakou; A Walker; H Bosmans; R Jacobs; R Bogaerts; K Horner
Journal:  Br J Radiol       Date:  2014-10       Impact factor: 3.039

8.  Optimization of dental CBCT exposures through mAs reduction.

Authors:  R Pauwels; L Seynaeve; J C G Henriques; C de Oliveira-Santos; P C Souza; F H Westphalen; I R F Rubira-Bullen; R F Ribeiro-Rotta; M I B Rockenbach; F Haiter-Neto; P Pittayapat; H Bosmans; R Bogaerts; R Jacobs
Journal:  Dentomaxillofac Radiol       Date:  2015-06-19       Impact factor: 2.419

9.  Effectiveness of thyroid gland shielding in dental CBCT using a paediatric anthropomorphic phantom.

Authors:  A Hidalgo; J Davies; K Horner; C Theodorakou
Journal:  Dentomaxillofac Radiol       Date:  2014-11-20       Impact factor: 2.419

Review 10.  Radiation-induced thyroid cancer: what we have learned from chernobyl.

Authors:  Yuri E Nikiforov
Journal:  Endocr Pathol       Date:  2006       Impact factor: 4.056

View more
  1 in total

1.  European consensus on patient contact shielding.

Authors:  Peter Hiles; Patrick Gilligan; John Damilakis; Eric Briers; Cristian Candela-Juan; Dario Faj; Shane Foley; Guy Frija; Claudio Granata; Hugo de Las Heras Gala; Ruben Pauwels; Marta Sans Merce; Georgios Simantirakis; Eliseo Vano
Journal:  Insights Imaging       Date:  2021-12-23
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.