Descriptive data of the torque at failure and angular deflection in the tested systems
| Surface area at D3 (mm2) | Torque at failure (gcm) | Angular deflection (degree) | ||||||
|---|---|---|---|---|---|---|---|---|
| Mean ± SD | Median | Range | Mean ± SD | Median | Range | |||
| PTU | S1 | 0.022 | 68.8 ± 25.1 | 77.6af | 25.5–101.2 | 347.9 ± 37.6 | 355aeg | 270–420 |
| S2 | 0.024 | 112.5 ± 30.5 | 108.6b | 60.6–182.2 | 367 ± 48.5 | 365af | 290–495 | |
| F1 | 0.048 | 100.6 ± 36.4 | 93.9abg | 63.3–169.8 | 380.3 ± 48.1 | 375bf | 295–480 | |
| F2 | 0.121 | 141.7 ± 37.6 | 136.3c | 90.82–235.5 | 346.7 ± 56.6 | 350aeg | 275–470 | |
| F3 | 0.149 | 196.2 ± 20.9 | 189.8d | 168.4–250.8 | 559 ± 62.4 | 540c | 450–690 | |
| PTG | S1 | 0.022 | 43.4 ± 14.9 | 41.6e | 22.2–80 | 361.7 ± 53.1 | 370abdef | 280–440 |
| S2 | 0.024 | 73.7 ± 33.3 | 66.3f | 37.4–179.0 | 331.0 ± 39.9 | 335e | 260–385 | |
| F1 | 0.048 | 94 ± 23.1 | 91.4b | 37.8–129.4 | 393.2 ± 60.6 | 390f | 285–495 | |
| F2 | 0.121 | 117.4 ± 32 | 115.5bcg | 70.6–201.2 | 371.3 ± 50.4 | 370fg | 280–495 | |
| F3 | 0.149 | 166.4 ± 17.2 | 167.4h | 135.1–194.5 | 580.3 ± 61.7 | 580c | 480–670 | |
| PTN | X1 | 0.048 | 59.9 ± 13.5 | 58.8f | 36.7–82.2 | 291.6 ± 35.8 | 280h | 220–360 |
| X2 | .094 | 95.8 ± 38.9 | 92ab | 44.3–185.1 | 303.1 ± 32.5 | 310h | 245–355 | |
| X3 | 0.137 | 115.4 ± 17.6 | 116.7i | 81.4–142.9 | 303.7 ± 26.3 | 300h | 270–355 | |
Different superscripts indicate statistical significance
Fig. 1Scanning electron microscopic images of ProTaper Universal, ProTaper Gold, and ProTaper Next instruments after the torsional resistance testing revealing circular abrasion streaks and skewed dimples in the center of the fractured surfaces. a PTU-S1, b PTU-S2, c PTU-F1, d PTU-F2, e PTU-F3, f PTG-S1, g PTG-S2, h PTG-F1, i PTG-F2, j PTG-F3, k PTN-X1, l PTN-X2, and m PTN-X3. n and o show the fracture characteristics that occurred after the torsional resistance testing