Literature DB >> 19084142

Defects in nickel-titanium instruments after clinical use. Part 1: Relationship between observed imperfections and factors leading to such defects in a cohort study.

Ya Shen1, Markus Haapasalo, Gary Shun-Pan Cheung, Bin Peng.   

Abstract

The purpose of this study was to examine three different types of nickel-titanium (NiTi) systems (ProTaper [Dentsply Maillefer, Ballaigues, Switzerland], ProTaper for Hand Use [Dentsply Maillefer], and K3 [SybronEndo, Orange, CA]) that were discarded by 3 endodontic clinics. The instruments were evaluated for defects and factors leading to instrument deformation or fracture. A total of 1682 instruments were collected over 16 months and were examined. The location of the defect, if any, was recorded. The overall prevalence of unwinding defects was 3% and fracture 5%; the rates differed significantly between clinics. For one brand (ProTaper) used at two different clinics, a defect rate (fracture and distortion combined) of 7% (clinic A) vs. 13% (clinic B) for Shaping files (P < 0.05), and about 4% vs. 10% for Finishing files (P < 0.05) was observed. Fragments of broken Shaping file were significantly longer in clinic A than for clinic B (P < 0.05). The lowest defect rate was found for K3 instruments: unwinding 1%, and fracture 3%. It was concluded that the defect rates of NiTi instruments were influenced by such factors as the operator, preparation technique and instrument design.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19084142     DOI: 10.1016/j.joen.2008.10.014

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  9 in total

1.  Sealer penetration: effect of separated file's cross-section, taper and motion characteristics.

Authors:  Ayhan Eymirli; Emel Uzunoğlu Özyürek; Ahmet Serper
Journal:  Clin Oral Investig       Date:  2020-06-19       Impact factor: 3.573

Review 2.  Endodontic Rotary Files, What Should an Endodontist Know?

Authors:  Ana-Belén Dablanca-Blanco; Pablo Castelo-Baz; Ramón Miguéns-Vila; Pablo Álvarez-Novoa; Benjamín Martín-Biedma
Journal:  Medicina (Kaunas)       Date:  2022-05-27       Impact factor: 2.948

3.  Shaping Ability of Reciproc Blue Versus One Curve in Curved Canal: An In-Vitro Study.

Authors:  Mohammad Daher Altufayli; Basem Salim; Imad Katbeh; Razan Merei; Zarina Mamasaidova
Journal:  Cureus       Date:  2022-04-22

4.  Evaluation of deformation and fracture rates for nickel-titanium rotary instruments according to the frequency of clinical use.

Authors:  Ayça Yılmaz; Sıtkı Selçuk Gökyay; Rüştü Dağlaroğlu; Işıl Karagöz Küçükay
Journal:  Eur Oral Res       Date:  2018-05-01

5.  Comparative evaluation of surface changes in four Ni-Ti instruments with successive uses - An SEM study.

Authors:  N Subha; Vimal K Sikri
Journal:  J Conserv Dent       Date:  2011-07

6.  Self-adjusting file (SAF) separation in clinical use: A preliminary survey among experienced SAF users regarding prevalence and retrieval methods.

Authors:  Michael Solomonov; Joe Ben-Itzhak; Anda Kfir; Oscar von Stetten; Elena Lipatova; Eleftherios T Farmakis
Journal:  J Conserv Dent       Date:  2015 May-Jun

7.  Incidence of Deformation and Fracture of Twisted File Adaptive Instruments after Repeated Clinical Use.

Authors:  Gianluca Gambarini; Lucila Piasecki; Dario Di Nardo; Gabriele Miccoli; Gianni Di Giorgio; Everdan Carneiro; Dina Al-Sudani; Luca Testarelli
Journal:  J Oral Maxillofac Res       Date:  2016-12-28

8.  Torsional resistance of three ProTaper rotary systems.

Authors:  Abdullah Alqedairi; Hussam Alfawaz; Bader Abualjadayel; Mohammad Alanazi; Ahmad Alkhalifah; Ahmed Jamleh
Journal:  BMC Oral Health       Date:  2019-06-21       Impact factor: 2.757

9.  Surgical removal of fractured endodontic instrument in the periapex of mandibular first molar.

Authors:  Adil Gandevivala; Bandish Parekh; Gaurav Poplai; Aliya Sayed
Journal:  J Int Oral Health       Date:  2014-07
  9 in total