Literature DB >> 27776878

Evaluation of the Cyclic Fatigue and Torsional Resistance of Novel Nickel-Titanium Rotary Files with Various Alloy Properties.

Mehmet Emin Kaval1, Ismail Davut Capar2, Hüseyin Ertas2.   

Abstract

INTRODUCTION: The purpose of this study was to evaluate the cyclic fatigue and torsional resistance of Hyflex EDM, ProTaper Gold (PTG), and ProTaper Universal (PTU) instruments.
METHODS: For the cyclic fatigue test, 10 instruments from each group were tested by using a stainless steel block with 1.5-mm diameter and 3-mm radius of 60° angle of curvature. The instruments were allowed to rotate by using a low-torque motor, and number of cycles from the beginning to the fracture was recorded. Torsional resistance of the instruments (n = 10) was evaluated according to ISO 3630-1. The rotational speed of the instruments was set in the clockwise direction at 2 rpm. The maximum torque and angular deflection until fracture of the instrument were recorded. The data were analyzed by using one-way analysis of variance followed by post hoc Tukey test (P = .05).
RESULTS: HyFlex EDM instruments exhibited the highest cyclic fatigue resistance and were followed by PTG and PTU groups, respectively. The mean fragment length for PTU instruments was significantly shorter than that for Hyflex EDM and PTG instruments. PTG instruments demonstrated significantly higher torsional resistance than HyFlex EDM files (P = .025), and the distortion angle of the instruments ranged as follows: PTU < PTG < Hyflex EDM files.
CONCLUSIONS: Hyflex EDM files demonstrated significantly higher cyclic fatigue resistance. Although PTG and PTU have similar cross-sectional design, PTG instruments presented higher cyclic fatigue and torsional resistance than PTU instruments. The enhanced alloy properties of PTG might be considered as the main reason for those differences.
Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cyclic fatigue; Hyflex EDM; electrical discharge machining; torsional resistance

Mesh:

Substances:

Year:  2016        PMID: 27776878     DOI: 10.1016/j.joen.2016.07.015

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  19 in total

1.  Cyclic fatigue and torsional strength of three different thermally treated reciprocating nickel-titanium instruments.

Authors:  Murilo Priori Alcalde; Marco Antonio Hungaro Duarte; Clovis Monteiro Bramante; Bruno Carvalho de Vasconselos; Mario Tanomaru-Filho; Juliane Maria Guerreiro-Tanomaru; Jader Camilo Pinto; Marcus Vinicius Reis Só; Rodrigo Ricci Vivan
Journal:  Clin Oral Investig       Date:  2017-12-09       Impact factor: 3.573

2.  Effect of autoclave sterilization on cyclic fatigue and torsional fracture resistance of NiTi rotary instruments.

Authors:  Wooyoung Kim; Soram Oh; Gil-Joo Ryu; Tae-Hwan Kim; Sung-Jae Kim; Dong-Hyung Kim; Bin-Na Lee; Kee-Yeon Kum; Seok Woo Chang; Ji-Hyun Jang
Journal:  Odontology       Date:  2019-09-11       Impact factor: 2.634

Review 3.  Endodontic Rotary Files, What Should an Endodontist Know?

Authors:  Ana-Belén Dablanca-Blanco; Pablo Castelo-Baz; Ramón Miguéns-Vila; Pablo Álvarez-Novoa; Benjamín Martín-Biedma
Journal:  Medicina (Kaunas)       Date:  2022-05-27       Impact factor: 2.948

4.  Torsional Behavior of WaveOne Gold Endodontic File with the Dedicated Motor of the Original WaveOne File.

Authors:  Jung-Hong Ha; Asgeir Sigurdsson; Gustavo De-Deus; Antheunis Versluis; Sang Won Kwak; Hyeon-Cheol Kim
Journal:  Materials (Basel)       Date:  2018-07-06       Impact factor: 3.623

Review 5.  Nickel-Titanium Rotary Instruments: Development of the Single-File Systems.

Authors:  Maryam Kuzekanani
Journal:  J Int Soc Prev Community Dent       Date:  2018-08-06

6.  Torsional resistance of three ProTaper rotary systems.

Authors:  Abdullah Alqedairi; Hussam Alfawaz; Bader Abualjadayel; Mohammad Alanazi; Ahmad Alkhalifah; Ahmed Jamleh
Journal:  BMC Oral Health       Date:  2019-06-21       Impact factor: 2.757

7.  Cyclic fatigue, bending resistance, and surface roughness of ProTaper Gold and EdgeEvolve files in canals with single- and double-curvature.

Authors:  Wafaa A Khalil; Zuhair S Natto
Journal:  Restor Dent Endod       Date:  2019-04-26

Review 8.  Nickel-Titanium Rotary File Systems: What's New?

Authors:  Sadia Tabassum; Kamil Zafar; Fahad Umer
Journal:  Eur Endod J       Date:  2019-10-18

9.  Effect of Sterilization on Cyclic Fatigue Resistance of Proflexendo Endodontic Rotary Files.

Authors:  Emad O Alshwaimi
Journal:  Saudi J Med Med Sci       Date:  2019-02-08

10.  Fracture and deformation of ProTaper Next instruments after clinical use.

Authors:  Gema Fernández-Pazos; Benjamín Martín-Biedma; Purificación Varela-Patiño; Manuel Ruíz-Piñón; Pablo Castelo-Baz
Journal:  J Clin Exp Dent       Date:  2018-11-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.