| Literature DB >> 31215416 |
Hong Koo Ha1,2,3, Henk B Luiting4,5, Petra L Graham6, Manish I Patel7,8, Jaspreet S Sandhu9, Oguz Akin10, Sean F Mungovan11,12,13.
Abstract
BACKGROUND: There is a change in the position of the remaining anatomical structures of the lower urinary tract system following radical prostatectomy. The aims of this investigation were to describe three novel methods used to measure the displacement of i) the vesico-urethral junction (VUJ), proximal membranous urethra (PMU) and anorectal junction (ARJ) and ii) the VUJ angle of displacement in men following radical prostatectomy and determine their intra- and interrater reliability.Entities:
Keywords: Displacement; Magnetic resonance imaging; Measurement; Reliability; Urethra; Urinary tract
Mesh:
Year: 2019 PMID: 31215416 PMCID: PMC6582582 DOI: 10.1186/s12894-019-0472-6
Source DB: PubMed Journal: BMC Urol ISSN: 1471-2490 Impact factor: 2.264
Fig. 1The three common axis systems that were investigated. a The pubococcygeal line (PCL) axis system was comprised of the line formed between the inferior rim of the pubic symphysis and the sacrococcygeal joint (PCL line) (X) and the perpendicular line to the PCL at the inferior rim of the pubic symphysis (Y). b The HOR-1 axis system was comprised of the horizontal line of the symphysis angle (X) and the line perpendicular to the horizontal line at the symphysis angle (Y). c The HOR-2 axis system was comprised of the horizontal line of the symphysis angle (X) and the line perpendicular to the horizontal line at the inferior rim of the pubic symphysis (Y)
Fig. 2The a) preoperative and b) postoperative T2W midsagittal MRI images showing the VUJ, PMU and ARJ anatomical landmarks
Fig. 3PCL Axis System: The a) preoperative VUJ (Depth 1-VUJ and Height 1-VUJ), b) postoperative VUJ (Depth 2-VUJ and Height 2-VUJ) c) VUJ postoperative displacement d) postoperative angle of displacement
Fig. 4HOR-1 Axis System: The a) preoperative VUJ (Depth 1-VUJ and Height 1-VUJ), b) postoperative VUJ (Depth 2-VUJ and Height 2-VUJ) c) VUJ postoperative displacement d) postoperative angle of displacement
Fig. 5HOR-2 Axis System: The a) preoperative VUJ (Depth 1-VUJ and Height 1-VUJ), b) postoperative VUJ (Depth 2-VUJ and Height 2-VUJ) c) VUJ postoperative displacement d) postoperative angle of displacement
Patient Characteristics (n = 20)
| Mean ± SD | Median (IQR) | Range | |
|---|---|---|---|
| Age (years) | 66.4 ± 5.5 | 66.5 (63.0, 71.5) | 53.0–74.0 |
| Preoperative PSA (ng.mL−1) | 15.4 ± 23.4 | 7.0 (4.2, 13.4) | 3.0–94.0 |
| Prostate volume (mL) | 30.7 ± 13.2 | 27.5 (20.6, 32.4) | 16.5–69.3 |
| Preoperative MUL (mm) | 13.4 ± 3.5 | 12.8 (12.2, 15.4) | 6.8–20.5 |
| Gleason Grade Group | n (%) | ||
| 1 | 7 (35) | ||
| 2 | 4 (20) | ||
| 3 | 6 (30) | ||
| 4 | 1 (5) | ||
| 5 | 2 (10) |
SD Standard deviation, IQR Interquartile range, MUL Membranous urethral length
The mean ± SD displacement (mm) of VUJ, PMU and ARJ and VUJ angle of displacement (degrees) measured using the pubococcygeal axis (PCL), HOR-1 and HOR-2 axis reference systems in 20 men following RP
| VUJ Displacement (mm) | PMU Displacement (mm) | ARJ Displacement (mm) | VUJ Angle of displacement (degrees) | |||||
|---|---|---|---|---|---|---|---|---|
| Day 1 | Day 2 | Day 1 | Day 2 | Day 1 | Day 2 | Day 1 | Day 2 | |
| PCL axis system | ||||||||
| Observer 1 | 34.1 ± 4.3 | 33.7 ± 4.7 | 4.1 ± 2.1 | 4.0 ± 1.6 | 3.5 ± 2.5 | 4.1 ± 2.6 | −16.9 ± 11.6 | −16.3 ± 11.4 |
| Observer 2 | 33.9 ± 4.9 | 4.7 ± 2.0 | 4.4 ± 2.5 | −16.8 ± 11.0 | ||||
| HOR-1 axis system | ||||||||
| Observer 1 | 34.9 ± 4.4 | 34.4 ± 4.6 | 4.2 ± 2.3 | 4.6 ± 2.2 | 4.0 ± 2.0 | 3.7 ± 1.9 | 13.9 ± 10.7 | 12.7 ± 11.0 |
| Observer 2 | 34.7 ± 5.0 | 5.3 ± 2.3 | 5.1 ± 2.6 | 11.8 ± 12.2 | ||||
| HOR-2 axis system | ||||||||
| Observer 1 | 34.8 ± 4.3 | 34.6 ± 4.9 | 4.0 ± 2.0 | 3.7 ± 1.9 | 3.9 ± 2.2 | 4.6 ± 2.5 | 13.0 ± 11.1 | 13.6 ± 11.1 |
| Observer 2 | 34.8 ± 5.1 | 4.2 ± 2.2 | 4.4 ± 2.44 | 13.6 ± 10.8 | ||||
VUJ Vesico-urethral junction, PMU Proximal membranous urethra, ARJ anorectal junction, PCL axis system: Pubococcygeal line axis system, HOR-1 axis system: Horizontal line 1 axis system, HOR-2 axis system: Horizontal line 2 axis system
Intra- and interrater reliability with 95% confidence interval (CI) for the measurement of displacement of the VUJ, PMU and ARJ (mm) and the VUJ angle of displacement (degrees)
| VUJ Displacement (mm) | PMU Displacement (mm) | ARJ Displacement (mm) | VUJ Angle of displacement (degrees) | |
|---|---|---|---|---|
| Intrarater Reliability ICC (95%CI) Day 1 vs Day 2 | ||||
| PCL axis system | 0.97 (0.93, 0.99) | 0.93 (0.84, 0.97) | 0.78 (0.53, 0.91) | 0.99 (0.98, 1.00) |
| HOR-1 axis system | 0.96 (0.90, 0.99) | 0.80 (0.58, 0.92) | 0.71 (0.38, 0.88) | 0.96 (0.89, 0.98) |
| HOR-2 axis system | 0.96 (0.91, 0.99) | 0.89 (0.74, 0.95) | 0.78 (0.51, 0.91) | 0.99 (0.97, 1.00) |
| Interrater Reliability ICC (95%CI) Observer 1 vs Observer 2 | ||||
| PCL axis system | 0.97 (0.93, 0.99) | 0.89 (0.75, 0.96) | 0.84 (0.63, 0.93) | 0.99 (0.96, 0.99) |
| HOR-1 axis system | 0.94 (0.85, 0.98) | 0.64 (0.26, 0.83) | 0.60 (0.22, 0.82) | 0.95 (0.87, 0.98) |
| HOR-2 axis system | 0.94 (0.86, 0.98) | 0.85 (0.67, 0.94) | 0.76 (0.48, 0.9) | 0.98 (0.95, 0.99) |
VUJ Urethrovesicular junction, PMU Proximal membranous urethra, ARJ anorectal junction, ICC Intra-class correlation coefficient, CI confidence interval, PCL axis system: Pubococcygeal line axis system, HOR-1 axis system: Horizontal line 1 axis system, HOR-2 axis system: Horizontal line 2 axis system
Mean ± SD of the differences between and within raters for the measures of displacement of the VUJ, PMU and ARJ (mm) and the VUJ angle of displacement (degrees)
| VUJ Displacement mm | PMU Displacement (mm) | ARJ Displacement (mm) | VUJ Angle of displacement (degrees) | |
|---|---|---|---|---|
| Mean difference within Observer 1 measurements. Day 1 vs Day 2 | ||||
| PCL axis system | −0.3 ± 1.0 | −0.1 ± 0.7 | 0.6 ± 1.6 | 0.6 ± 1.5 |
| HOR-1 axis system | − 0.5 ± 1.1 | 0.4 ± 1.4 | 0.9 ± 1.7 | −1.2 ± 3.1 |
| HOR-2 axis system | −0.2 ± 1.3 | −0.3 ± 0.9 | 0.6 ± 1.5 | 0.8 ± 1.3 |
| Mean difference between Observer 1 and Observer 2 measurements | ||||
| PCL axis system | 0.2 ± 1.1 | 0.5 ± 0.9 | 0.8 ± 1.4 | 0.0 ± 2.0 |
| HOR-1 axis system | 0.2 ± 1.6 | 1.1 ± 2.0 | 0.8 ± 2.3 | −2.0 ± 3.7 |
| HOR-2 axis system | 0.0 ± 1.6 | −0.2 ± 1.3 | 0.5 ± 1.6 | 0.8 ± 2.2 |
VUJ Vesiculo-urethral junction, PMU Proximal membranous urethra, ARJ anorectal junction, PCL axis system: Pubococcygeal line axis system, HOR-1 axis system Horizontal line 1 axis system, HOR-2 axis system Horizontal line 2 axis system