A gold foil electrode: extending the horizons for clinical electroretinography.

G B Arden, R M Carter, C Hogg, I M Siegel, S Margolis.   

Abstract

A gold foil ERG electrode is described. The device is inexpensive and simple to fabricate. Since it is hooked over the lower lid and makes minimal touch contact with the inferior limbal area, it can be used in circumstances which require prolonged testing of retinal function or in eyes with corneal pathology. Because the optics of the eye are not compromised, it is possible, with the use of appropriate stimuli and response-averaging techniques, to record local EFGs from relatively small retinal areas.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 311765

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  53 in total

1.  Visual prognostic value of the pattern electroretinogram in chiasmal compression.

Authors:  D N Parmar; A Sofat; R Bowman; J R Bartlett; G E Holder
Journal:  Br J Ophthalmol       Date:  2000-09       Impact factor: 4.638

2.  Scotopic versus photopic pattern onset-offset electroretinograms.

Authors:  S Pallas; W Schmidt; E Dodt
Journal:  Doc Ophthalmol       Date:  1992       Impact factor: 2.379

3.  New noncorneal HK-loop electrode for clinical electroretinography.

Authors:  M Hawlina; B Konec
Journal:  Doc Ophthalmol       Date:  1992       Impact factor: 2.379

4.  Retinal origin of VECP delays as revealed by simultaneously recorded ERG to patterned stimuli.

Authors:  R Lorenz; W Heider
Journal:  Doc Ophthalmol       Date:  1990-08       Impact factor: 2.379

5.  Microcomputer-based recording system for clinical electrophysiology.

Authors:  B Török
Journal:  Doc Ophthalmol       Date:  1990-09       Impact factor: 2.379

6.  Fundamental differences between the nonlinearities of pattern and focal electroretinograms.

Authors:  E E Sutter
Journal:  Doc Ophthalmol       Date:  1990-11       Impact factor: 2.379

7.  Pattern electroretinogram in glaucoma and ocular hypertension.

Authors:  M Bach; A Speidel-Fiaux
Journal:  Doc Ophthalmol       Date:  1989-10       Impact factor: 2.379

8.  Sensitivity distribution in the central and midperipheral visual field determined by pattern electroretinography and harmonic analysis.

Authors:  R Marx; E Zrenner
Journal:  Doc Ophthalmol       Date:  1989-12       Impact factor: 2.379

9.  Transient corneal changes associated with the use of gold foil electrodes.

Authors:  G W Aylward; K A McClellan; R Thomas; F A Billson
Journal:  Br J Ophthalmol       Date:  1989-12       Impact factor: 4.638

10.  Obtaining a contact lens acquired electroretinogram in the presence of topical anesthetic hypersensitivity.

Authors:  Joan Parkinson; Francois Tremblay
Journal:  Doc Ophthalmol       Date:  2007-11-06       Impact factor: 2.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.