Literature DB >> 2276319

Microcomputer-based recording system for clinical electrophysiology.

B Török1.   

Abstract

We developed a personal computer-based system for clinical electrophysiologic measurements. The computer interfaced with a commercially available A/D converter, a low-noise isolation preamplifier, filter circuits, pattern and Ganzfeld stimulators, and a hardcopy unit. Separate programs were developed for electroretinography (ERG), pattern ERG and simultaneous visual evoked potential (VEP), flash and pattern-shift VEP, and electro-oculographic measurements. The complete control of the applied hardware (eg, stimulus control, automatic gain, and filter selection) is a common feature of the computer programs. These programs provide oscilloscopic functions, overload protection, artifact elimination, averaging, automatic peak latency and amplitude determination, baseline correction, smoothing, and digital filtering. The results can be presented on matrix, laser printers, or digital plotters. The hardware components and the features of the driver software are demonstrated on normal and pathologic signals.

Entities:  

Mesh:

Year:  1990        PMID: 2276319     DOI: 10.1007/bf00146555

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  5 in total

1.  A Ganzfeld stimulator for electroretinography.

Authors:  R D Gunkel; D R Bergsma; P Gouras
Journal:  Arch Ophthalmol       Date:  1976-04

2.  A gold foil electrode: extending the horizons for clinical electroretinography.

Authors:  G B Arden; R M Carter; C Hogg; I M Siegel; S Margolis
Journal:  Invest Ophthalmol Vis Sci       Date:  1979-04       Impact factor: 4.799

3.  A full-field system for clinical electroretinography.

Authors:  A R Rabin; E L Berson
Journal:  Arch Ophthalmol       Date:  1974-07

4.  A low noise isolated amplifier system for electrophysiological measurements: basic considerations and design.

Authors:  R van Heuningen; H G Goovaerts; F R de Vries
Journal:  Med Biol Eng Comput       Date:  1984-01       Impact factor: 2.602

5.  A new type of electrode for recording pattern electroretinograms and visual-evoked potentials simultaneously.

Authors:  P Salu; R Trau
Journal:  Am J Ophthalmol       Date:  1983-04       Impact factor: 5.258

  5 in total
  3 in total

1.  Pattern electroretinogram and visual evoked potential amplitudes are influenced by different stimulus field sizes and scotomata.

Authors:  A Junghardt; H Wildberger; Y Robert; B Török
Journal:  Doc Ophthalmol       Date:  1993       Impact factor: 2.379

2.  A personal computer-based visual evoked potential stimulus and recording system.

Authors:  M S Bradnam; A L Evans; D M Montgomery; D Keating; B E Damato; A Cluckie; D Allan
Journal:  Doc Ophthalmol       Date:  1994       Impact factor: 2.379

3.  Pattern electroretinogram, visual evoked potential and psychophysical functions in maculopathy.

Authors:  A Junghardt; H Wildberger; B Török
Journal:  Doc Ophthalmol       Date:  1995       Impact factor: 2.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.