Literature DB >> 1468355

New noncorneal HK-loop electrode for clinical electroretinography.

M Hawlina1, B Konec.   

Abstract

A new noncorneal electrode for clinical electroretinography was developed. It consists of a thin wire forming a loop modeled to fit into the lower conjunctival sac. Electrical contact is made with the scleral conjunctiva through an exposed portion of otherwise insulated wire. The recorded pattern electroretinograms are in the same amplitude range as if recorded by the gold foil electrode, while the flash electroretinograms with the new electrode are of about two-thirds the amplitude of corneal electrodes. The new electrode is more durable and hence less expensive than gold foil electrodes and can likewise be used without topical anesthetic. Cleaning is easy and effective. The electrode rarely causes discomfort and produces stable responses for at least 2 hours. The electrode aims to match stability of skin electrodes with sensitivity of fragile foil and fiber electrodes.

Mesh:

Year:  1992        PMID: 1468355     DOI: 10.1007/bf00156014

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  8 in total

1.  The effect of gold foil electrode position on the electroretinogram in human subjects.

Authors:  A McAllan; J Sinn; G W Aylward
Journal:  Vision Res       Date:  1989       Impact factor: 1.886

2.  Transient corneal changes associated with the use of gold foil electrodes.

Authors:  G W Aylward; K A McClellan; R Thomas; F A Billson
Journal:  Br J Ophthalmol       Date:  1989-12       Impact factor: 4.638

3.  A gold foil electrode: extending the horizons for clinical electroretinography.

Authors:  G B Arden; R M Carter; C Hogg; I M Siegel; S Margolis
Journal:  Invest Ophthalmol Vis Sci       Date:  1979-04       Impact factor: 4.799

4.  A method for more comfortable electroretinography.

Authors:  W W Dawson; T J Zimmerman; W L Houde
Journal:  Arch Ophthalmol       Date:  1974-01

5.  Variability of the pattern electroretinogram.

Authors:  K Holopigian; J Snow; W Seiple; I Siegel
Journal:  Doc Ophthalmol       Date:  1988-09       Impact factor: 2.379

6.  Pattern electroretinogram recorded by skin electrodes in early ocular hypertension and glaucoma.

Authors:  M Hawlina; M Strucl; B Stirn-Kranjc; Z Finderle; J Brecelj
Journal:  Doc Ophthalmol       Date:  1989-10       Impact factor: 2.379

7.  Improved electrode for electroretinography.

Authors:  W W Dawson; G L Trick; C A Litzkow
Journal:  Invest Ophthalmol Vis Sci       Date:  1979-09       Impact factor: 4.799

8.  ERG electrode in pediatric patients: comparison of DTL fiber, PVA-gel, and non-corneal skin electrodes.

Authors:  S G Coupland; M Janaky
Journal:  Doc Ophthalmol       Date:  1989-04       Impact factor: 2.379

  8 in total
  27 in total

1.  Electroretinographic evaluation of the retinal S-cone system.

Authors:  Maja Sustar; Marko Hawlina; Jelka Brecelj
Journal:  Doc Ophthalmol       Date:  2011-11-27       Impact factor: 2.379

2.  [Electrophysiological examination methods in glaucoma diagnostics].

Authors:  C M Poloschek; M Bach
Journal:  Ophthalmologe       Date:  2012-04       Impact factor: 1.059

3.  Electrophysiological assessment of glaucomatous visual dysfunction during treatment with cytidine-5'-diphosphocholine (citicoline): a study of 8 years of follow-up.

Authors:  Vincenzo Parisi
Journal:  Doc Ophthalmol       Date:  2005-01       Impact factor: 2.379

4.  ON- and OFF-response of the photopic electroretinogram in relation to stimulus characteristics.

Authors:  Maja Sustar; Marko Hawlina; Jelka Brecelj
Journal:  Doc Ophthalmol       Date:  2006-08-12       Impact factor: 2.379

5.  Electroretinography and optical coherence tomography reveal abnormal post-photoreceptoral activity and altered retinal lamination in patients with enhanced S-cone syndrome.

Authors:  M Sustar; D Perovšek; I Cima; B Stirn-Kranjc; M Hawlina; J Brecelj
Journal:  Doc Ophthalmol       Date:  2015-02-07       Impact factor: 2.379

6.  The effect of broadband and monochromatic stimuli on the photopic negative response of the electroretinogram in normal subjects and in open-angle glaucoma patients.

Authors:  Maja Sustar; Barbara Cvenkel; Jelka Brecelj
Journal:  Doc Ophthalmol       Date:  2008-10-19       Impact factor: 2.379

7.  Treatment with citicoline eye drops enhances retinal function and neural conduction along the visual pathways in open angle glaucoma.

Authors:  Vincenzo Parisi; Marco Centofanti; Lucia Ziccardi; Lucia Tanga; Manuele Michelessi; Gloria Roberti; Gianluca Manni
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-05-26       Impact factor: 3.117

8.  Ganglion cell loss in early glaucoma, as assessed by photopic negative response, pattern electroretinogram, and spectral-domain optical coherence tomography.

Authors:  Barbara Cvenkel; Maja Sustar; Darko Perovšek
Journal:  Doc Ophthalmol       Date:  2017-05-31       Impact factor: 2.379

9.  Obtaining a contact lens acquired electroretinogram in the presence of topical anesthetic hypersensitivity.

Authors:  Joan Parkinson; Francois Tremblay
Journal:  Doc Ophthalmol       Date:  2007-11-06       Impact factor: 2.379

10.  Fundus albipunctatus in a 6-year old girl due to compound heterozygous mutations in the RDH5 gene.

Authors:  Alessandro Iannaccone; Salvatore A Tedesco; Kevin T Gallaher; Hiroyuki Yamamoto; Steve Charles; Thaddeus P Dryja
Journal:  Doc Ophthalmol       Date:  2007-05-03       Impact factor: 2.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.