Literature DB >> 18534379

Total hip arthroplasty with the Secur-Fit and Secur-Fit plus femoral stem design a brief follow-up report at 5 to 10 years.

Stephen J Incavo1, Bruce D Beynnon, Kathryn M Coughlin.   

Abstract

This report represents a 5- to 10-year follow-up of our initial 2- to 5-year data with this proximally hydroxyapatite-coated stem design (Secur-Fit, Stryker Orthopaedics, Mahwah, NJ). This is a retrospective review of a single surgeon's consecutive cases. A total of 105 cases were available for complete review. The average follow-up was 6.7 years (60-123 months). All stems achieved bony ingrowth. Harris hip score and Oxford hip score averaged to 91 and 17, respectively, with no differences seen between the 132 degrees and the 127 degrees stem designs. Leg length measurements were considered equal side-to-side differences of 7 mm or less in 87% of cases: 82% of standard- and 92% of high-offset cases (P < .05). Four cases of osteolysis were identified and occurred only in patients with an elevated rim liner, implicating neck-liner impingement. The stem design performed exceedingly well over the course of this study. Having a high-offset option aids the surgeon in proper leg length management.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18534379     DOI: 10.1016/j.arth.2007.05.044

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

1.  Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?

Authors:  Adrian Bauze; Somen Agrawal; Alana Cuthbert; Richard de Steiger
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

2.  Periprosthetic fractures may be more likely in cementless femoral stems with sharp edges.

Authors:  K Hu; X Zhang; J Zhu; C Wang; W Ji; X Bai
Journal:  Ir J Med Sci       Date:  2009-10-22       Impact factor: 1.568

Review 3.  Use of elevated liners in primary total hip arthroplasty: a systematic review of the literature.

Authors:  Ioannis Gkiatas; Theofilos Karasavvidis; Abhinav K Sharma; William Xiang; Michael-Alexander Malahias; Brian P Chalmers; Seth A Jerabek; Peter K Sculco
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-05-29

4.  Clinical and Radiological Outcomes of Rectangular Tapered Cementless Stem According to Proximal Femoral Geometry in Elderly Asian Patients.

Authors:  Joon Soon Kang; Sang Hyun Ko; Yeop Na; Yung Hun Youn
Journal:  Hip Pelvis       Date:  2019-11-28
  4 in total