Literature DB >> 10794226

The spatial location of impingement in total hip arthroplasty.

M Yamaguchi1, T Akisue, T W Bauer, Y Hashimoto.   

Abstract

Impingement between acetabular and femoral components produces wear debris and results in abnormal loads on the edge of the implant. To characterize further the spatial location of impingement and the design and alignment factors associated with impingement, we reviewed 111 retrieved acetabular components from a single manufacturer. The location of impingement in the pelvis was determined by combining the location of impingement in the retrieved implants and the spatial orientation of the acetabular components measured from available radiographs. Evidence of impingement was identified in 39% of the retrieved implants and involved the posterior portion of the acetabulum in all cases. Posterior impingement was probably the result of femoral extension and external rotation, a motion that occurs during the toe-off phase of the gait cycle. Cups with impingement were more anteverted than those without impingement (P = .016). There was a significant inverse association between impingement and the size of the femoral head, and the mean head-to-neck diameter ratio for implants with impingement was smaller than that for implants without impingement (P < .0001). Factors that appear to be associated with impingement include i) excessive cup anteversion combined with posterior positioning of the extended rim and ii) femoral components with relatively small head-to-neck diameter ratio.

Entities:  

Mesh:

Year:  2000        PMID: 10794226     DOI: 10.1016/s0883-5403(00)90601-6

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  26 in total

Review 1.  Edge loading has a paradoxical effect on wear in metal-on-polyethylene total hip arthroplasties.

Authors:  William H Harris
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Comparison of robotic-assisted and conventional acetabular cup placement in THA: a matched-pair controlled study.

Authors:  Benjamin G Domb; Youssef F El Bitar; Adam Y Sadik; Christine E Stake; Itamar B Botser
Journal:  Clin Orthop Relat Res       Date:  2013-08-29       Impact factor: 4.176

3.  Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?

Authors:  Adrian Bauze; Somen Agrawal; Alana Cuthbert; Richard de Steiger
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

4.  Effects of implant design parameters on fluid convection, potentiating third-body debris ingress into the bearing surface during THA impingement/subluxation.

Authors:  Hannah J Lundberg; Douglas R Pedersen; Thomas E Baer; Marian Muste; John J Callaghan; Thomas D Brown
Journal:  J Biomech       Date:  2007-04-02       Impact factor: 2.712

5.  Six sigma analysis of minimally invasive acetabular arthroplasty: a preliminary investigation.

Authors:  David A Heck; James B Stiehl
Journal:  Clin Orthop Relat Res       Date:  2009-05-22       Impact factor: 4.176

6.  Validation of a simple radiographic method to determine variations in pelvic and acetabular cup sagittal plane alignment after total hip arthroplasty.

Authors:  Won Yong Shon; Siddhartha Gupta; Sandeep Biswal; Chang Yong Hur; Nirmal Jajodia; Suk Joo Hong; Jae Sung Myung
Journal:  Skeletal Radiol       Date:  2008-08-07       Impact factor: 2.199

Review 7.  Acetabular orientation: anterolateral approach in the supine position.

Authors:  Matthew S Austin; Richard H Rothman
Journal:  Clin Orthop Relat Res       Date:  2008-10-01       Impact factor: 4.176

8.  Effects of episodic subluxation events on third body ingress and embedment in the THA bearing surface.

Authors:  Anneliese D Heiner; Hannah J Lundberg; Thomas E Baer; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  J Biomech       Date:  2008-06-17       Impact factor: 2.712

9.  Validation of navigation assisted cup placement in total hip arthroplasty.

Authors:  M Ajith Kumar; M Shantharam Shetty; Kanthi G Kiran; Abhishek R Kini
Journal:  Int Orthop       Date:  2011-05-03       Impact factor: 3.075

10.  Do large femoral heads reduce the risks of impingement in total hip arthroplasty with optimal and non-optimal cup positioning?

Authors:  Gianluca Cinotti; Niccolò Lucioli; Andrea Malagoli; Carlo Calderoli; Ferdinando Cassese
Journal:  Int Orthop       Date:  2010-02-17       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.