A comparative study of the accuracy of five CAD-CAM systems.

Smaranda Buduru1, Bogdan Culic2, Daniel Talmaceanu3, Adorjan Pal1.   

Abstract

BACKGROUND AND AIMS: The study aims at comparing the precision of different CAD/CAM systems: original systems built by the same manufacturer as opposed to systems whose components are built by different manufacturers.
METHODS: We used the same physical cast which was scanned with five different scanners. The design of the PMMA copings was done by the same operator for the five virtual casts. Each coping was milled three times by each milling machine, thus obtaining 75 copings. The internal space was analyzed by scanning the replicas in light body silicone.
RESULTS: The results analyzed the vertical marginal space (VMS) at the preparation limit, the axial internal space (AIS) and the internal occlusal space (IOS). For VMS the best results were obtained for scanner no 5 (S5) and milling machine 3 (M3). For AIS the best results were obtained with S4 and M3 combination. For IOS the best results were obtained with S45 and M3 combination.
CONCLUSIONS: According to the results of the study, we are able to confirm the working hypothesis by stating the following conclusions: the quality of the prosthetic elements obtained through CAD/CAM processing differs depending on the CAD/CAM system used and is influenced by each component of every system individually, both the scanner and the milling unit; changing/switching any component of the CAD/CAM system has an impact on the quality of the resulting prosthetic work, but in an unpredictable manner.

Entities:  

Keywords:  CAD/CAM; Monobrand/Hybrid systems; vertical marginal space

Year:  2019        PMID: 31086848      PMCID: PMC6510363          DOI: 10.15386/cjmed-1131

Source DB:  PubMed          Journal:  Med Pharm Rep        ISSN: 2602-0807


Background and aims

Among the cutting-edge technologies available in dental medicine, CAD/CAM systems based on 3D scanners (intraoral or model), computer aided design (CAD) and computer aided manufacturing (CAM) in different (additive or subtractive) forms, have witnessed a remarkable development in the last years. The main target for using CAD/CAM systems in dental care is related to the desire to eliminate human error in the manufacturing of prosthetic elements. The variety of CAD/CAM systems available on the market raises several questions concerning the quality of prosthetic works manufactured by using different systems. The technological complexity, structural variety or IT diversity, namely the vast number of manufacturers, also account for the qualitative differences between prosthetic works manufactured by using different CAD/CAM systems. The distinctive variables of these systems make even more difficult the predictability and reproducibility of the results, thus leading to various and complex qualitative and functional discrepancies. Although there are many studies [1-4] dedicated to various qualitative aspects specific of prosthetic works manufactured by using CAD/CAM systems, the conclusions of the papers are often contradictory and do not supply at first sight a clear picture of the predictability of the investigated systems or of the factors that have an impact on the quality of prosthetic works. The study aims at comparing the precision of different CAD/CAM systems, original systems built by the same manufacturer, as well as systems whose components are built by different manufacturers. The working hypothesis is to establish the superiority of the hybrid (scanner and milling unit from different manufacturers) over the original monobrand system (scanner and milling unit originating from the same manufacturer) or vice versa.

Methods

In the present study, we decided to make 75 PMMA copings by using 5 different lab scanners and 5 different milling units. We used a tooth (4.6) prepared for the substructure (the coping) of a crown. The 75 PMMA copings were made on the tooth by using 5 different scanners and they were then analyzed from different perspectives: vertical marginal space at the preparation limit, axial internal space at the middle of the axial wall height and internal occlusal space in 2 distinct points. Five CAD/CAM systems installed in different laboratories were used in the study, and they were selected according to the following inclusion criteria: milling unit with the same number of rotation axes, below 15 μm acknowledged scanner precision (according to the technical data published by the manufacturer), model manufactured after 2014, PMMA milling capacity, open system or one that has modules allowing the users to work with open .STL files, compatibility with exocad dentalCAD 2016. In order to avoid potential ethical or legal issues, we decided to encrypt the commercial denomination of the CAD/CAM systems included in the study. The configuration of the systems based on the codes resulted after randomization is detailed in table I.
Table I

Encryption of the CAD/CAM systems and components.

5 monobrand systemsC1C2C3C4C5
5 scannersS1S2S3S4S5
5 milling unitsM1M2M3M4M5
25 new CAD/CAM systems (obtained by recombining the scanners and milling units of the monobrand systems)S1M1S2M1S3M1S4M1S5M1
S1M2S2M2S3M2S4M2S5M2
S1M3S2M3S3M3S4M3S5M3
S1M4S2M4S3M4S4M4S5M4
S1M5S2M5S3M5S4M5S5M5
We used the letter “C” for complete systems consisting of a scanner (denoted by “S”) and a milling unit (denoted by “M”) provided by the same manufacturer. The table reveals that C1=S1+M1, C2=S2+M2 ….. C5=S5+M5 (i.e. Cx=Sx+Mx). Twenty-five other CAD/CAM systems with components from different manufacturers can be obtained by recombination (Sy+Mx). A working cast with mobile abutment for tooth 4.6 (the homothetic tooth reduction was done with 1.2 mm chamfer margin and 1.5 mm occlusal surface reduction) was fabricated and mounted on the semi-adjustable articulator. The cast was sent to be scanned to 5 different laboratories that had their respective 5 CAD/CAM systems included in the study, thus producing 5 different virtual casts of the same physical working cast. All 5 virtual casts were then sent to the same design center separately in order to design the copings using the CAD. We decided to manufacture PMMA copings. One coping was designed for each virtual model, abiding by the same criteria and set parameters during the design stage: 0 vertical marginal space, 50 μm cement gap, and coping thickness of 1 mm evenly following the contour of the preparation, which decreases towards the marginal area depending on the thickness required by the marginal design. The exocad DentalCAD 2016 software was used by the same operator, on the same computer simultaneously, and on the same day. Thus, 5 virtual copings were designed and saved in .STL files, originating from the same physical cast and identically designed under the same circumstances; the only difference between the 5 copings was that the virtual cast came from different scanners. Each virtual coping was sent to all the 5 milling units, so each laboratory in part received all the 5 .STL files for milling. Consequently, each milling unit made 3 copies of all 5 virtual copings, that is 5 virtual copings × 5 milling units × 3 copies = 75 copings (Figure 1).
Figure 1

Schematic representation of the design process.

Standard 98 and 95ZZ Bilkim PMMA discs, 16 mm in width and A2 shade were used for milling. In order to evaluate how the copings fit on the physical cast, a replica of the internal and marginal space was made using light body Polyvinyl Siloxane from a cartridge with two components, later fixed with putty Polyvinyl Siloxane. Materials used: a. cylinder to stabilize the mobile abutment, filled with putty Polyvinyl Siloxane 2 mm below the marginal preparation to hold the mobile abutment in central position; b. piston to place the coping on the abutment, to which a column-shaped container with 1.5 l water is attached (the water maintains constant pressure); c. support for the water container meant to maintain a stable direction of the force the water exerts on the coping and on the abutment; d. lid for stabilizing the light body silicone into the putty silicone, which has 2 markings on the inside providing the reference points for precise cutting in the next stage. In practice, a set quantity of light body silicone was used to take an impression of the internal and marginal space for each coping, and then the piston with the water container was positioned perpendicularly on the occlusal surface of the coping so that the force were directly exerted on the central axis of the mobile abutment. The force was applied for 90 seconds, then the piston and the coping were removed and the thin layer of light body silicone remained attached to the mobile abutment. Next, the putty silicone was put in the application lid by using the same piston with the attached water container of 1.5 l for 90 seconds. After removing the application lid, the fluid silicone was attached and stabilized into the putty silicone (Figure 2).
Figure 2

Internal space impression.

The silicone blocks were sectioned in buccal-lingual and mesial-distal direction on the cutting reference points marked on the inner side of the stabilizing lid. We used a professional, 120W power, self-sharpening cutting tool with smooth edge disc and stabilizing system for the silicone block according to the markings (Figure 3).
Figure 3

Sections of the internal replicas prepared for scanning.

Each silicone block was cut into 2 mm-thick slices, and each slice was scanned from the same direction using a Konica Minolta BizHub C452 scanner at a maximum resolution of 600 dpi (7015×4960 pixels). The digital images thus acquired were imported into the Bersoft Image Management software program, which measures the distances between 2 points of the image in the analysis window using its own measurements units (data units) that are pixel fractions. In the Bersoft Image Management program, we determined the thickness of the light body silicone layer in 6 points for each section, as follows: - Vertical marginal space at the preparation limit, both buccally and orally (2 measurements), using the abbreviations VMS (VMSb for the buccal area, and VMSo for the oral area); - Axial internal space at the middle of the axial wall height, both buccally and orally; the measurement was carried out perpendicularly on the axial wall (2 measurements), using the abbreviations AIS (AISb and AISo); - Internal occlusal space in 2 distinct points, the tip of the buccal cusps resulted after preparation and the central fossa, namely 2 measurements abbreviated IOSc and IOSf. The resulting values were expressed in data units (fractions/multiples of pixels), converted then into μm with the conversion application.

Results

Based on the values obtained after converting the units measured for VMS, AIS, and IOS in μm, we proceeded to applying the “Descriptive Statistics”/Data analysis from Microsoft Office Excel, which emphasized the following: the means, modules and medians had almost equal values, while the values of asymmetry (Skewness) and of the excess (Kurtosis) were close to 0, with some isolated exceptions. By analyzing these values, and by taking into account the rather small sample size under investigation, we concluded that the data recorded in the experimental study should be regarded as parametrical data with a relatively normal distribution, therefore we applied the Fisher test (the f test) in order to perform variance analysis. The test resulted in equal or unequal variances, according to which we performed the corresponding test for each case individually. The results are summarized in tables II, III and IV.
Table II

“p” values after applying the t test for the VMS means.

S1S2S3S4S5
M10.64610.65540.12390.0228S1

M20.32200.35590.30870.1081S2

M30.00820.00790.00920.0006S3

M40.04720.09410.02730.1631S4

M50.74550.37140.01110.3766S5

M1M2M3M4M5
Table III

“p” values after applying the t test for the AIS means.

S1S2S3S4S5
M10.82990.10460.03860.0394S1

M20.60390.40190.11640.1182S2

M30.06080.17700.00070.0073S3

M40.03010.29570.50840.9889S4

M50.22600.60210.32400.5923S5

M1M2M3M4M5
Table IV

“p” values after applying the t test for the IOS means.

S1S2S3S4S5
M10.94920.27390.02790.0217S1

M20.87860.54470.04990.5779S2

M30.04970.44920.00420.0001S3

M40.00170.37320.99710.8849S4

M50.71970.67630.51770.7174S5

M1M2M3M4M5
Tables V, VI, and VII display the precision results for the tested systems.
Table V

Precision classification of the tested components and systems.

SpaceComponents classificationTop 3 systems
IIIIIIIVVIIIIII
VMSS3S1S2S4S5S3M2S2M2S2M1
M2M1M5M4M3
C2C1C5C3C4
AISS3S2S1S4S5S2M1S3M5S3M1
M1M2M5M4M3
C3C2C1C5C4
IOSS3S1S2S4S5S1M1S3M3S2M1
M1M2M3M5M4
C1C3C2C4C5
Table VI

Precision of monobrand systems.

SxMx=CxS1M1=C1S2M2=C2S3M3=C3S4M4=C4S5M5=C5
VMS45.8328.8379.8394.0075.00
AIS97.5062.5062.33161.33149.83
IOS70.50141.5082.50199.50207.83
Table VII

Classification of monobrand systems.

Based exclusively on scanning precision
12345
VMSC1C2C5C3 = C4
AISC3 = C2C1C5C4
IOSC1C3C2C4 = C5

Discussion

Even if all 5 scanners operate according to the same optical principle and use blue light, the built-in optical cameras differ in terms of resolution and focalizing speed. The inspection of the milled copings did not reveal any important differences in terms of surface finishing, milling quality or marginal area integrity. Therefore, we can assert that all the tested systems displayed similar performances in terms of qualitative surface and marginal integrity parameters. In the first fitting on the abutment, without light body silicone, all the copings showed good, similar, adequate marginal adaptation, being seated on the marginal preparation without any distancing or visually detectable VMS oscillations. The inspection of the internal and marginal space light body silicone replicas of all the copings on the abutment immediately after their removal endorsed the conclusion of other studies, namely that the internal space is not uniform, as it should ideally be according to the CAD design. There were several more transparent silicone zones (areas), with thinner silicone layers, and the transparent zones/areas were not in the same region at each impression-taking, but differed from one impression to another or from one coping to the other. The obtained values of the VMS, AIS and IOS showed that the CAD/CAM systems did not conform to the CAD settings and did not faithfully reproduce the space designed and intended for the cement gap. Therefore, VMS was never 0, and the measured IOS was not equal to the measured VMS added to the CAD spacing. We noticed that in the case of the 3 theoretically identical copings, milled by each system apart, the VMS, AIS or IOS were not identical either, or all measured values were the same. Even if the differences between the 3 “identical” copings were usually minor and statistically insignificant, they, however, should not have existed in theory. Following the analysis of individual results, the best values were generally found in the new combinations of components built by different manufacturers. The study enabled us to check the statistical significance of the differences between each system apart and all the other analyzed systems and the result was that from 300 possible combinations (combinations of 25 taken 2 at a time) only 59 proved statistically insignificant, i.e. 19%. In other words, 81% of the differences revealed by the study between the precision of the tested systems were statistically significant; consequently in 81% of the cases 1 of the 2 compared systems displayed a significantly higher precision than the other. The gold standard for quality evaluation and clinical success of fixed prosthetic is marginal adaptation [1,2]. Usually, the VMS is set to 0 beginning with the CAD stage, and the internal space, depending on manifold factors, may be set to different values ranging between 20 – 80 μm [3,4]. A series of studies have established the optimal range for the physical VMS of prosthetics between 40 and 120 μm [5,6,7]. Other studies indicate that the maximum acceptable limit is 100 μm; consequently, it can be stated that the generally acknowledged clinically acceptable range for the marginal space is 40–100 μm [8]. The literature in the field indicates different values for the VMS [9]: for zirconia-based dental prosthetics, values ranging between 60 and 74 μm are mentioned [9,10]; for ceramic single unit fixed partial dentures, 64 – 83 μm [10], 50 – 75 μm [11], a mean of 56 μm [12] or 51.7 μm [13]. Other studies range the VMS between 39.1 and 201 μm or 10 and 110 μm. Some sources indicate that the VMS values range between 9.94 and 308.92 μm [14]. The AIS value ranges also vary, but on a larger scale: 23–230 μm, 23.5 – 219.12 μm, 51 – 442 μm [15]. Most of the studies indicate VMSs below 80 μm, a value considered to be clinically acceptable, however far above the ADA recommended range for the VMS (25 – 40 μm) [15]. The results should be interpreted taking into account the limitations of the study both in what concerns the investigated CAD/CAM systems (located in different environments, operated by different specialists, with different burs, some of the settings, use time or wear, etc.) and the measurements and determinations (difference in the rheological properties of the silicone and of the cementation materials, different application load in contrast with the clinically applied force when cementing, elastic properties of the silicone not present in cements, the possibility to compress the light body silicone layer during stabilization with putty silicone, etc.). In relation to the methods of control of the investigated variables mentioned by the surveyed literature in the field, the present study fits into the common standards of studying the CAD/CAM precision in vitro. Another important limitation arises from the number of milled copings for each individual case - in our study the number is n=3 – as well as from the number of sections, namely number of measurements performed for each section.

Conclusions

According to the results of the study and taking into account the given limitations, we are able to confirm the working hypothesis by stating the following conclusions: the quality of prosthetic elements obtained through CAD/CAM processing differs depending on the CAD/CAM system used and is influenced by each component of every system apart, both the scanner and the milling unit; changing/switching any component of the CAD/CAM system has an impact on the quality of the resulting prosthetic work, but in an unpredictable manner. The internal space of the prosthetic work built with the CAD/CAM systems is not uniform and displays important variations depending on the surface and height at which the measurement is taken. The spacing value set during the CAD stage (the thickness of the space designed for the cementing material) always influences the final VMS, sometimes inversely proportional and unpredictably, and the exact initially set value of the spacing is not preserved in the internal space of the milled prosthetic piece. We may configure new CAD/CAM systems using CAD/CAM components built by different manufacturers. These new systems may ensure a superior quality of the finite product over the original systems.
  14 in total

1.  Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system.

Authors:  J Tinschert; G Natt; W Mautsch; H Spiekermann; K J Anusavice
Journal:  Oper Dent       Date:  2001 Jul-Aug       Impact factor: 2.440

2.  Precision of a CAD/CAM technique for the production of zirconium dioxide copings.

Authors:  Pierluigi Coli; Stig Karlsson
Journal:  Int J Prosthodont       Date:  2004 Sep-Oct       Impact factor: 1.681

3.  Clinical marginal and internal gaps of zirconia all-ceramic crowns.

Authors:  Yuji Kokubo; Mitsuyoshi Tsumita; Takamitsu Kano; Satoe Sakurai; Shunji Fukushima
Journal:  J Prosthodont Res       Date:  2010-10-08       Impact factor: 4.642

4.  Influence of CAD/CAM systems and cement selection on marginal discrepancy of zirconia-based ceramic crowns.

Authors:  Francisco Martínez-Rus; María J Suárez; Begoña Rivera; Guillermo Pradíes
Journal:  Am J Dent       Date:  2012-04       Impact factor: 1.522

5.  Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems.

Authors:  Sven Reich; Manfred Wichmann; Emeka Nkenke; Peter Proeschel
Journal:  Eur J Oral Sci       Date:  2005-04       Impact factor: 2.612

Review 6.  A systematic review of the clinical performance of CAD/CAM single-tooth restorations.

Authors:  Julia-Gabriela Wittneben; Robert F Wright; Hans-Peter Weber; German O Gallucci
Journal:  Int J Prosthodont       Date:  2009 Sep-Oct       Impact factor: 1.681

7.  Comparative analysis of two measurement methods for marginal fit in metal-ceramic and zirconia posterior FPDs.

Authors:  Esther Gonzalo; María J Suárez; Benjamin Serrano; José F L Lozano
Journal:  Int J Prosthodont       Date:  2009 Jul-Aug       Impact factor: 1.681

Review 8.  Digital dentistry: an overview of recent developments for CAD/CAM generated restorations.

Authors:  F Beuer; J Schweiger; D Edelhoff
Journal:  Br Dent J       Date:  2008-05-10       Impact factor: 1.626

9.  CAD/CAM Dental technology.

Authors:  Edward McLaren
Journal:  Compend Contin Educ Dent       Date:  2011-05

Review 10.  Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs: a literature review.

Authors:  Noor A Nawafleh; Florian Mack; Jane Evans; John Mackay; Muhanad M Hatamleh
Journal:  J Prosthodont       Date:  2013-01-04       Impact factor: 2.752

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.