Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs: a literature review.

Noor A Nawafleh1, Florian Mack, Jane Evans, John Mackay, Muhanad M Hatamleh.   

Abstract

PURPOSE: To review methods used to investigate marginal adaptation of crowns and fixed dental prostheses (FDPs), and to discuss testing variables employed and their influence on results.
METHODS: Online libraries including PubMed, Scopus, and Ovid were searched for articles evaluating the marginal adaptation of crowns and FDPs using a combination of the keywords: "marginal accuracy," "marginal fit," "marginal gap," "marginal discrepancy," "fitting accuracy," "crown," and "FPD." Peer-reviewed publications in English in the period 1970 to December 2011 were collected, evaluated by their abstract, and included if they met the inclusion criteria. The criteria involved studies evaluating marginal adaptation of crowns and FDPs through clear experimental protocols. Exclusion criteria involved longitudinal prospective and retrospective clinical evaluations, studies using subjective tactile sensation, and other predefined criteria.
RESULTS: A total of 277 papers were identified; only 183 met the inclusion criteria. Direct view technique was used by 47.5% of the articles followed by cross-sectioning (23.5%), and impression replica (20.2%) techniques. The marginal gap values reported by these techniques varied among individual crown systems and across different systems because of variations in study type (in vivo vs. in vitro), sample size and measurements per specimen, finish line design, and stage at which the marginal gap was measured.
CONCLUSION: There was a substantial lack of consensus relating to marginal adaptation of various crown systems due to differences in testing methods and experimental protocols employed. Direct view technique was the most commonly used method of reproducible results. Also, conducting an experimental set-up of testing a minimum of 30 specimens at 50 measurements per specimen should produce reliable results. Additionally, using a combination of two measurement methods can be useful in verification of results.
© 2012 by the American College of Prosthodontists.

Keywords:  Crown fit; FDP fit; fitting accuracy; marginal fit

Mesh:

Year:  2013        PMID: 23289599     DOI: 10.1111/jopr.12006

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  38 in total

1.  In vitro evaluation of prosthodontic impression on natural dentition: a comparison between traditional and digital techniques.

Authors:  G Malaguti; R Rossi; B Marziali; A Esposito; G Bruno; C Dariol; A DI Fiore
Journal:  Oral Implantol (Rome)       Date:  2017-02-14

2.  Trueness of four different milling procedures used in dental CAD/CAM systems.

Authors:  Corinna Kirsch; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

3.  Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue.

Authors:  Petra C Guess; Thaleia Vagkopoulou; Yu Zhang; Martin Wolkewitz; Joerg R Strub
Journal:  J Dent       Date:  2013-10-24       Impact factor: 4.379

4.  A comparison of the marginal adaptation of composite overlays fabricated with silicone and an intraoral scanner.

Authors:  Carla García-Cuesta; Vicente Faus-Llácer; Álvaro Zubizarreta-Macho; René Botello-Torres; Vicente Faus-Matoses
Journal:  J Clin Exp Dent       Date:  2021-05-01

5.  Evaluating the effect of repeated use of milling burs on surface roughness and adaptation of digitally fabricated ceramic veneers.

Authors:  Leila Payaminia; Naeime Moslemian; Shima Younespour; Soudabeh Koulivand; Marzieh Alikhasi
Journal:  Heliyon       Date:  2021-04-30

6.  Effect of Fabrication Technique on the Microgap of CAD/CAM Cobalt-Chrome and Zirconia Abutments on a Conical Connection Implant: An In Vitro Study.

Authors:  Pedro Molinero-Mourelle; Rocio Cascos-Sanchez; Burak Yilmaz; Walter Yu Hang Lam; Edmond Ho Nang Pow; Jaime Del Río Highsmith; Miguel Gómez-Polo
Journal:  Materials (Basel)       Date:  2021-04-30       Impact factor: 3.623

7.  Correlation between Microleakage and Absolute Marginal Discrepancy in Zirconia Crowns Cemented with Four Resin Luting Cements: An In Vitro Study.

Authors:  Abad-Coronel Cristian; Li Jeanette; Martínez-Rus Francisco; Pradíes Guillermo
Journal:  Int J Dent       Date:  2016-09-18

8.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

9.  Marginal adaptation of three-unit interim restorations fabricated by the CAD-CA systems and the direct method before and after thermocycling.

Authors:  Leyla Sadighpour; Farideh Geramipanah; Mehran Falahchai; Hasan Tadbiri
Journal:  J Clin Exp Dent       Date:  2021-06-01

10.  The marginal and internal discrepancy of zirconia coping milled by two computer-aided design-computer-aided manufacturing systems.

Authors:  Somchai Urapepon
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.