Literature DB >> 19639075

Comparative analysis of two measurement methods for marginal fit in metal-ceramic and zirconia posterior FPDs.

Esther Gonzalo1, María J Suárez, Benjamin Serrano, José F L Lozano.   

Abstract

The purpose of this study was to compare two measurement methods for the external marginal fit of zirconia posterior fixed partial dentures (FPDs) fabricated using computer-aided design/manufacturing technology and metal-ceramic posterior FPDs fabricated using the conventional lost-wax technique. The null hypothesis was that there would be no differences between the measurement methods. Forty standardized steel specimens were prepared to receive posterior three-unit FPDs. Specimens were divided into four groups (n = 10): (1) metal-ceramic, (2) Procera Bridge Zirconia, (3) Lava AllCeramic System, and (4) Vita In-Ceram YZ 2000. All FPDs were luted with glass-ionomer cement (Ketac Cem EasyMix, 3M ESPE). Two measurement methods were used to analyze marginal fit: an image analysis (IA) program and a scanning electron microscope (SEM) (JEOL JSM-6400) with magnifications of 340 and 31,000, respectively. Marginal fit was measured at the same point on each abutment. Significant interaction was observed between measurement method and material (P = .0019). Therefore, the measurement method is not independent of the restoration material. Differences among groups were observed for IA (P = .0001) and SEM (P = .0013). Significant differences were observed for the Procera (P = .0050) and metal-ceramic (P = .0039) specimen groups when both measurement methods were evaluated separately. Accuracy of fit achieved by the four groups analyzed was within the range of clinical acceptance, yielding Procera Bridge Zirconia to have the best marginal fit using both measurement methods.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19639075

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  10 in total

1.  Adaptation of all-ceramic fixed partial dentures.

Authors:  Márcia Borba; Paulo F Cesar; Jason A Griggs; Álvaro Della Bona
Journal:  Dent Mater       Date:  2011-09-13       Impact factor: 5.304

2.  Internal fit evaluation of indirect restorations fabricated from CAD/CAM composite blocks versus ceramic blocks in badly broken teeth using cone beam CT (CBCT): double-blinded randomized clinical trial.

Authors:  Shereen Hafez Ibrahim; Haitham Amr; Ahmed A Hassan; Ahmed Elzohairy
Journal:  Heliyon       Date:  2022-05-19

3.  Maxillary rehabilitation of periodontally compromised patients with extensive one-piece fixed prostheses supported by natural teeth: a retrospective longitudinal study.

Authors:  Alexander Heschl; Michael Haas; Josef Haas; Michael Payer; Walther Wegscheider; Raoul Polansky
Journal:  Clin Oral Investig       Date:  2013-01       Impact factor: 3.573

4.  Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques.

Authors:  Mi-Jung Yun; Young-Chan Jeon; Chang-Mo Jeong; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2017-02-07       Impact factor: 1.904

5.  A comparative study of the accuracy of five CAD-CAM systems.

Authors:  Smaranda Buduru; Bogdan Culic; Daniel Talmaceanu; Adorjan Pal
Journal:  Med Pharm Rep       Date:  2019-04-25

6.  The marginal and internal discrepancy of zirconia coping milled by two computer-aided design-computer-aided manufacturing systems.

Authors:  Somchai Urapepon
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun

7.  The clinical challenge of achieving marginal adaptation in direct and indirect restorations.

Authors:  Karin Hermana Neppelenbroek
Journal:  J Appl Oral Sci       Date:  2015-10       Impact factor: 2.698

8.  Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems.

Authors:  Tae-Jin Song; Taek-Ka Kwon; Jae-Ho Yang; Jung-Suk Han; Jai-Bong Lee; Sung-Hun Kim; In-Sung Yeo
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

9.  Comparison the Marginal and Internal Fit of Metal Copings Cast from Wax Patterns Fabricated by CAD/CAM and Conventional Wax up Techniques.

Authors:  M Vojdani; K Torabi; E Farjood; Aar Khaledi
Journal:  J Dent (Shiraz)       Date:  2013-09

10.  Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study.

Authors:  Sujana Ullattuthodi; Kandathil Phillip Cherian; R Anandkumar; M Sreedevi Nambiar
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.