Literature DB >> 15543914

Precision of a CAD/CAM technique for the production of zirconium dioxide copings.

Pierluigi Coli1, Stig Karlsson.   

Abstract

PURPOSE: The precision of a computer-aided design/manufacturing (CAD/CAM) system to manufacture zirconium dioxide copings with a predetermined internal space was investigated.
MATERIALS AND METHODS: Two master models were produced in acrylic resin. One was directly scanned by the Decim Reader. The Decim Producer then manufactured 10 copings from prefabricated zirconium dioxide blocks. Five copings were prepared, aiming for an internal space to the master of 45 microm. The other five copings were prepared for an internal space of 90 microm. The second test model was used to try in the copings produced. The obtained internal space of the ceramic copings was evaluated by separate measurements of the master models and inner surfaces of the copings. The master models were measured at predetermined points with an optical instrument. The zirconium dioxide copings were measured with a contact instrument at the corresponding sites measured in the masters.
RESULTS: The first group of copings had a mean internal space to the scanned master of 41 microm and of 53 microm to the try-in master. In general, the internal space along the axial walls of the masters was smaller than that along the occlusal walls. The second group had a mean internal space of 82 microm to the scanned master and of 90 microm to the try-in master.
CONCLUSION: The aimed-for internal space of the copings was achieved by the manufacturer. The CAD/CAM technique tested provided high precision in the manufacture of zirconium dioxide copings.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15543914

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  15 in total

1.  Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

Authors:  Philipp Kohorst; Janet Junghanns; Marc P Dittmer; Lothar Borchers; Meike Stiesch
Journal:  Clin Oral Investig       Date:  2010-05-22       Impact factor: 3.573

2.  Precision of fit: zirconia three-unit fixed dental prostheses.

Authors:  Florian Beuer; Michael Naumann; Wolfgang Gernet; John A Sorensen
Journal:  Clin Oral Investig       Date:  2008-09-04       Impact factor: 3.573

3.  Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials.

Authors:  Joana Schönberger; Kurt-Jürgen Erdelt; Daniel Bäumer; Florian Beuer
Journal:  Clin Oral Investig       Date:  2017-02-04       Impact factor: 3.573

4.  Clinical performance of screw-retained and cemented implant-supported zirconia single crowns: 36-month results.

Authors:  Claudio Cacaci; Friederike Cantner; Thomas Mücke; Peter Randelzhofer; Jan Hajtó; Florian Beuer
Journal:  Clin Oral Investig       Date:  2016-10-29       Impact factor: 3.573

5.  In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials.

Authors:  Yu-Sung Choi; Sung-Hun Kim; Jai-Bong Lee; Jung-Suk Han; In-Sung Yeo
Journal:  J Adv Prosthodont       Date:  2012-08-28       Impact factor: 1.904

6.  Influence of surface modification techniques on shear bond strength between different zirconia cores and veneering ceramics.

Authors:  Ramin Mosharraf; Mansour Rismanchian; Omid Savabi; Alireza Hashemi Ashtiani
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

7.  Evaluation of different approaches for using a laser scanner in digitization of dental impressions.

Authors:  Wan-Sun Lee; Woong-Chul Kim; Hae-Young Kim; Wook-Tae Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

8.  The marginal and internal discrepancy of zirconia coping milled by two computer-aided design-computer-aided manufacturing systems.

Authors:  Somchai Urapepon
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun

9.  Marginal and internal fit of zirconia based fixed dental prostheses fabricated with different concepts.

Authors:  Florian Beuer; Natalie Korczynski; Antonia Rezac; Michael Naumann; Wolfgang Gernet; John A Sorensen
Journal:  Clin Cosmet Investig Dent       Date:  2010-02-25

10.  Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems.

Authors:  Tae-Jin Song; Taek-Ka Kwon; Jae-Ho Yang; Jung-Suk Han; Jai-Bong Lee; Sung-Hun Kim; In-Sung Yeo
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.