Literature DB >> 30958796

A detector's eye view (DEV)-based OSEM algorithm for benchtop x-ray fluorescence computed tomography (XFCT) image reconstruction.

Luzhen Deng1, Md F Ahmed, Sandun Jayarathna, Peng Feng, Biao Wei, Sang Hyun Cho.   

Abstract

In this study, we developed a detector's eye view (DEV)-based ordered subsets expectation maximization (OSEM) algorithm for more accurate reconstruction of benchtop x-ray fluorescence computed tomography (XFCT) images. The proposed approach was tested using two sets of benchtop XFCT imaging data derived from a newly performed gold nanoparticle (GNP)-containing phantom imaging study and a previously published postmortem benchtop XFCT imaging study of a tumor-bearing mouse injected with GNPs. DEV-based OSEM resulted in higher spatial resolution (up to ~20% decrease in the full width at half maximum values of the regions of interest), compared with filtered back-projection (FBP) and traditional OSEM. It also resulted in up to an order of magnitude smaller background noise in the reconstructed images than FBP, while producing consistently less background noise than traditional OSEM.

Entities:  

Mesh:

Year:  2019        PMID: 30958796      PMCID: PMC7029789          DOI: 10.1088/1361-6560/ab0e9d

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

2.  Maximum likelihood reconstruction for emission tomography.

Authors:  L A Shepp; Y Vardi
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

3.  The feasibility of polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects: a Monte Carlo study.

Authors:  Bernard L Jones; Sang Hyun Cho
Journal:  Phys Med Biol       Date:  2011-05-31       Impact factor: 3.609

Review 4.  Elemental and chemically specific X-ray fluorescence imaging of biological systems.

Authors:  M Jake Pushie; Ingrid J Pickering; Malgorzata Korbas; Mark J Hackett; Graham N George
Journal:  Chem Rev       Date:  2014-08-07       Impact factor: 60.622

5.  Longitudinal image deblurring in spiral CT.

Authors:  F J Schlueter; G Wang; P S Hsieh; J A Brink; D M Balfe; M W Vannier
Journal:  Radiology       Date:  1994-11       Impact factor: 11.105

6.  EM reconstruction algorithms for emission and transmission tomography.

Authors:  K Lange; R Carson
Journal:  J Comput Assist Tomogr       Date:  1984-04       Impact factor: 1.826

7.  Technical Note: A benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system with a high-power x-ray source and transmission CT imaging capability.

Authors:  Nivedh Manohar; Francisco J Reynoso; Sang Hyun Cho
Journal:  Med Phys       Date:  2018-09-14       Impact factor: 4.071

8.  First demonstration of multiplexed X-ray fluorescence computed tomography (XFCT) imaging.

Authors:  Yu Kuang; Guillem Pratx; Magdalena Bazalova; Bowen Meng; Jianguo Qian; Lei Xing
Journal:  IEEE Trans Med Imaging       Date:  2012-10-11       Impact factor: 10.048

9.  Experimental demonstration of benchtop x-ray fluorescence computed tomography (XFCT) of gold nanoparticle-loaded objects using lead- and tin-filtered polychromatic cone-beams.

Authors:  Bernard L Jones; Nivedh Manohar; Francisco Reynoso; Andrew Karellas; Sang Hyun Cho
Journal:  Phys Med Biol       Date:  2012-11-08       Impact factor: 3.609

10.  Quantitative imaging of gold nanoparticle distribution in a tumor-bearing mouse using benchtop x-ray fluorescence computed tomography.

Authors:  Nivedh Manohar; Francisco J Reynoso; Parmeswaran Diagaradjane; Sunil Krishnan; Sang Hyun Cho
Journal:  Sci Rep       Date:  2016-02-25       Impact factor: 4.379

View more