Literature DB >> 7972755

Longitudinal image deblurring in spiral CT.

F J Schlueter1, G Wang, P S Hsieh, J A Brink, D M Balfe, M W Vannier.   

Abstract

PURPOSE: To assess the feasibility of digital deconvolution techniques to improve longitudinal resolution of spiral computed tomography (CT) multiplanar reformations and evaluate how technical factors in deconvolution affect longitudinal resolution, noise, and edge ringing.
MATERIALS AND METHODS: Longitudinal line spread function (LSF) of the system was estimated from longitudinal reformations of transaxial spiral CT images of a step test phantom. By using the estimated LSF, longitudinal reformations of the phantom and three clinical spiral CT studies were deconvolved by the methods of Wiener filtering and constrained iterative deconvolution. Edge ringing and image noise were quantified for Wiener filtering and constrained iterative deconvolution.
RESULTS: Longitudinal reformations were substantially deblurred and resolution improved after deconvolution. Anatomic boundaries in clinical images were more clearly delineated after restoration. The methods of Wiener deconvolution and constrained iterative deconvolution improved the sharpness of the phantom step boundary at the expense of increased edge ringing and image noise.
CONCLUSION: In longitudinal spiral CT reformations, blurring along the longitudinal axis can be reduced by Wiener filtering or constrained iterative deconvolution.

Entities:  

Mesh:

Year:  1994        PMID: 7972755     DOI: 10.1148/radiology.193.2.7972755

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

1.  Finite detector based projection model for high spatial resolution.

Authors:  Hengyong Yu; Ge Wang
Journal:  J Xray Sci Technol       Date:  2012       Impact factor: 1.535

2.  A scheme for multisource interior tomography.

Authors:  Ge Wang; Hengyong Yu; Yangbo Ye
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

3.  Statistical interior tomography.

Authors:  Qiong Xu; Xuanqin Mou; Ge Wang; Jered Sieren; Eric A Hoffman; Hengyong Yu
Journal:  IEEE Trans Med Imaging       Date:  2011-01-13       Impact factor: 10.048

4.  Axial T1ρ MRI as a diagnostic imaging modality to quantify proteoglycan concentration in degenerative disc disease.

Authors:  Kyle R Mulligan; Catherine E Ferland; Rahul Gawri; Arijitt Borthakur; Lisbet Haglund; Jean A Ouellet
Journal:  Eur Spine J       Date:  2014-09-19       Impact factor: 3.134

5.  A detector's eye view (DEV)-based OSEM algorithm for benchtop x-ray fluorescence computed tomography (XFCT) image reconstruction.

Authors:  Luzhen Deng; Md F Ahmed; Sandun Jayarathna; Peng Feng; Biao Wei; Sang Hyun Cho
Journal:  Phys Med Biol       Date:  2019-04-08       Impact factor: 3.609

6.  Interior tomography with continuous singular value decomposition.

Authors:  Xin Jin; Alexander Katsevich; Hengyong Yu; Ge Wang; Liang Li; Zhiqiang Chen
Journal:  IEEE Trans Med Imaging       Date:  2012-08-15       Impact factor: 10.048

7.  A Geant4-based Monte Carlo study of a benchtop multi-pinhole X-ray fluorescence computed tomography imaging.

Authors:  Luzhen Deng; Biao Wei; Peng He; Yi Zhang; Peng Feng
Journal:  Int J Nanomedicine       Date:  2018-11-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.