The feasibility of polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects: a Monte Carlo study.

Bernard L Jones1, Sang Hyun Cho.   

Abstract

A recent study investigated the feasibility to develop a bench-top x-ray fluorescence computed tomography (XFCT) system capable of determining the spatial distribution and concentration of gold nanoparticles (GNPs) in vivo using a diagnostic energy range polychromatic (i.e. 110 kVp) pencil-beam source. In this follow-up study, we examined the feasibility of a polychromatic cone-beam implementation of XFCT by Monte Carlo (MC) simulations using the MCNP5 code. In the current MC model, cylindrical columns with various sizes (5-10 mm in diameter) containing water loaded with GNPs (0.1-2% gold by weight) were inserted into a 5 cm diameter cylindrical polymethyl methacrylate phantom. The phantom was then irradiated by a lead-filtered 110 kVp x-ray source, and the resulting gold fluorescence and Compton-scattered photons were collected by a series of energy-sensitive tallies after passing through lead parallel-hole collimators. A maximum-likelihood iterative reconstruction algorithm was implemented to reconstruct the image of GNP-loaded objects within the phantom. The effects of attenuation of both the primary beam through the phantom and the gold fluorescence photons en route to the detector were corrected during the image reconstruction. Accurate images of the GNP-containing phantom were successfully reconstructed for three different phantom configurations, with both spatial distribution and relative concentration of GNPs well identified. The pixel intensity of regions containing GNPs was linearly proportional to the gold concentration. The current MC study strongly suggests the possibility of developing a bench-top, polychromatic, cone-beam XFCT system for in vivo imaging.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21628767     DOI: 10.1088/0031-9155/56/12/017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  25 in total

1.  Experimental validation of L-shell x-ray fluorescence computed tomography imaging: phantom study.

Authors:  Magdalena Bazalova-Carter; Moiz Ahmad; Lei Xing; Rebecca Fahrig
Journal:  J Med Imaging (Bellingham)       Date:  2015-10-08

2.  Experimental demonstration of novel imaging geometries for x-ray fluorescence computed tomography.

Authors:  Geng Fu; Ling-Jian Meng; Peter Eng; Matt Newville; Phillip Vargas; Patrick La Riviere
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

3.  Proton-induced x-ray fluorescence CT imaging.

Authors:  Magdalena Bazalova-Carter; Moiz Ahmad; Taeko Matsuura; Seishin Takao; Yuto Matsuo; Rebecca Fahrig; Hiroki Shirato; Kikuo Umegaki; Lei Xing
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

Review 4.  The potential of L-shell X-ray fluorescence CT (XFCT) for molecular imaging.

Authors:  Magdalena Bazalova-Carter
Journal:  Br J Radiol       Date:  2015-07-24       Impact factor: 3.039

5.  Development of bimetallic (Zn@Au) nanoparticles as potential PET-imageable radiosensitizers.

Authors:  Jongmin Cho; Min Wang; Carlos Gonzalez-Lepera; Osama Mawlawi; Sang Hyun Cho
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

6.  L-shell x-ray fluorescence computed tomography (XFCT) imaging of Cisplatin.

Authors:  Magdalena Bazalova; Moiz Ahmad; Guillem Pratx; Lei Xing
Journal:  Phys Med Biol       Date:  2013-12-13       Impact factor: 3.609

7.  Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging.

Authors:  Sandun Jayarathna; Md Foiez Ahmed; Liam O'Ryan; Hem Moktan; Yonggang Cui; Sang Hyun Cho
Journal:  IEEE Access       Date:  2021-03-29       Impact factor: 3.367

8.  Feasibility study of Compton cameras for x-ray fluorescence computed tomography with humans.

Authors:  Don Vernekohl; Moiz Ahmad; Garry Chinn; Lei Xing
Journal:  Phys Med Biol       Date:  2016-11-15       Impact factor: 3.609

9.  Technical Note: A benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system with a high-power x-ray source and transmission CT imaging capability.

Authors:  Nivedh Manohar; Francisco J Reynoso; Sang Hyun Cho
Journal:  Med Phys       Date:  2018-09-14       Impact factor: 4.071

10.  Order of magnitude sensitivity increase in X-ray Fluorescence Computed Tomography (XFCT) imaging with an optimized spectro-spatial detector configuration: theory and simulation.

Authors:  Moiz Ahmad; Magdalena Bazalova; Liangzhong Xiang; Lei Xing
Journal:  IEEE Trans Med Imaging       Date:  2014-05       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.