| Literature DB >> 30820282 |
Sepehr Feizi1,2, Mohammad Ali Javadi2.
Abstract
PURPOSE: To evaluate the effects of donor graft thickness on postoperative best spectacle-corrected visual acuity (BSCVA), refractive outcomes, endothelial cell density (ECD) and function, intraocular pressure (IOP), and postoperative complications after Descemet stripping automated endothelial keratoplasty (DSAEK).Entities:
Keywords: Clinical Outcomes; Descemet Stripping Automated Endothelial Keratoplasty; Donor Graft Thickness
Year: 2019 PMID: 30820282 PMCID: PMC6388529 DOI: 10.4103/jovr.jovr_55_17
Source DB: PubMed Journal: J Ophthalmic Vis Res ISSN: 2008-322X
Comparisons of the demographic and operative data of the patients who received donor grafts with postoperative central thickness of <100 μm (group 1) versus ≥100 μm (group 2) during Descemet stripping automated endothelial keratoplasty (DSAEK)
| Recipient features | Group 1 ( | Group 2 ( | |
|---|---|---|---|
| Sex (male/female) | 14/18 | 16/16 | 0.18 |
| Laterality (OD/OS) | 21/14 | 19/23 | 0.35 |
| Preoperative diagnosis ( | 0.23 | ||
| Fuchs’ dystrophy | 19 (54.3) | 17 (40.5) | |
| Bullous keratopathy | 16 (45.7) | 25 (59.5) | |
| Lens status at the time of surgery ( | 0.52 | ||
| Phakic | 16 (45.7) | 17 (40.5) | |
| Pseudophakic | 19 (54.3) | 25 (59.5) | |
| Surgical technique ( | 0.99 | ||
| Stand-alone DSAEK | 21 (60.0) | 25 (59.5) | |
| DSAEK combined with cataract surgery | 14 (40.0) | 17 (40.5) |
Comparisons of data relevant to donor grafts with postoperative central thickness of <100 μm (group 1) versus ≥100 μm (group 2) that were transplanted during Descemet stripping automated endothelial keratoplasty
| Donor features | Group 1 ( | Group 2 ( | |
|---|---|---|---|
| Age (years) | 29.9±10.5 | 30.6±10.8 | 0.83 |
| Sex (male/female) | 28/7 | 40/2 | 0.17 |
| Death-to-preservation time ( | 0.29 | ||
| <20 h | 9 | 6 | |
| 20 to <30 h | 9 | 21 | |
| 30 to 40 h | 17 | 15 | |
| Storage time (days) | 1.42±0.61 | 1.37±0.60 | 0.79 |
| Endothelial cell density (cells/mm2) | 3045.6±298.9 | 3140.2±263.5 | 0.29 |
| Mean cell area (μm2) | 331.9±32.4 | 322.4±27.2 | 0.34 |
| Hexagonality (%) | 61.5±12.3 | 62.2±12.5 | 0.87 |
| Coefficient of variation | 34.5±6.2 | 33.6±7.4 | 0.70 |
| Donor quality ( | 0.99 | ||
| Excellent | 7 (20.0) | 8 (19.1) | |
| Very good | 28 (80.0) | 34 (80.9) | |
| Trephination size (mm) | 8.0±0.22 | 8.04±0.19 | 0.63 |
Figure 1Comparison of change in best spectacle-corrected visual acuity (BSCVA) from baseline to 2 years between the two groups of eyes receiving different donor graft thicknesses (<100 μm versus ≥100 μm) during Descemet stripping automated endothelial keratoplasty (P > 0.05 for all comparisons).
Comparisons of the prevalence of postoperative complications (n; %) in the two groups that underwent Descemet stripping automated endothelial keratoplasty and received donor grafts with postoperative central thickness <100 μm (group 1) versus ≥100 μm (group 2)
| Postoperative complications | Group 1 ( | Group 2 ( | |
|---|---|---|---|
| Graft non-attachment | 2 (5.7) | 0 | 0.22 |
| Graft decentration | 0 | 3 (7.1) | 0.49 |
| Interface haziness | 0 | 1 (2.4) | >0.99 |
| Graft folding | 1 (2.9) | 0 | >0.99 |
| Urrets-Zavalia syndrome | 1 (2.9) | 0 | >0.99 |
| Iridocorneal adhesion | 1 (2.9) | 2 (4.8) | >0.99 |
| High intraocular pressure | 7 (20.0) | 8 (19.1) | >0.99 |
| Endothelial graft rejection | 13 (37.1) | 12 (28.6) | 0.58 |
Comparisons of postoperative endothelial cell features (mean±standard deviation; range) between the two study groups that underwent Descemet stripping automated endothelial keratoplasty and received donor grafts with postoperative thickness of <100 μm (group 1) versus ≥100 μm (group 2)
| Endothelial cell features | Group 1 ( | Group 2 ( | |
|---|---|---|---|
| Density (cells/mm2) | 1458.4±571.6 (612.0 to 2213.0) | 2075.8±715.9 (666.0 to 3213.0) | 0.004 |
| Mean cell area (μm2) | 814.3±363.4 (452.0 to 1633.9) | 571.0±300.0 (311.2 to 1501.7) | 0.02 |
| Hexagonality (%) | 50.6±11.7 (32.1 to 78.4) | 53.6±12.0 (16.7 to 74.0) | 0.42 |
| Coefficient of variation | 37.6±7.2 (17.8 to 43.5) | 35.9±7.3 (21.9 to 57.9) | 0.60 |
Figure 2A scattergram illustrating a positive, significant correlation between postoperative central graft thickness and intraocular pressure in eyes undergoing Descemet stripping automated endothelial keratoplasty (r = 0.42, P = 0.005). Dotted lines indicate 95% confidence intervals for the regression line.
Figure 4A scattergram illustrating a negative, significant correlation between postoperative central graft thickness and recipient thickness in eyes undergoing Descemet stripping automated endothelial keratoplasty (r = −0.46, P = 0.002). Dotted lines indicate 95% confidence intervals for the regression line.